This part of IEC 60079 is concerned with the classification of areas where flammable gas or vapour hazards may arise and may then be used as a basis to support the proper selection and installation of equipment for use in hazardous areas. It is intended to be applied where there may be an ignition hazard due to the presence of flammable gas or vapour, mixed with air, but it does not apply to: a) mines susceptible to firedamp; b) the processing and manufacture of explosives; c) catastrophic failures or rare malfunctions which are beyond the concept of abnormality dealt with in this standard (see 3.7.3 and 3.7.4); d) rooms used for medical purposes; e) commercial and industrial applications where only low pressure fuel gas is used for appliances e. g. for cooking, water heating and similar uses, where the installation is compliant with relevant gas codes; f) domestic premises; g) where a hazard may arise due to the presence of combustible dusts or combustible flyings but the principles may be used in assessment of a hybrid mixture (refer also IEC 60079-10-2). NOTE Additional guidance on hybrid mixtures is provided in Annex I. Flammable mists may form or be present at the same time as flammable vapour. In such case the strict application of the details in this standard may not be appropriate. Flammable mists may also form when liquids not considered to be a hazard due to the high flash point are released under pressure. In these cases the classifications and details given in this standard do not apply. Information on flammable mists is provided in Annex G. For the purpose of this standard, an area is a three-dimensional region or space. Atmospheric conditions include variations above and below reference levels of 101,3 kPa (1013 mbar) and 20 °C (293 K), provided that the variations have a negligible effect on the explosion properties of the flammable substances. In any process plant, irrespective of size, there may be numerous sources of ignition apart from those associated with equipment. Appropriate precautions will be necessary to ensure safety in this context. This standard is applicable with judgement for other ignition sources. This standard does not take into account the consequences of ignition of an explosive atmosphere.
IEC 60079-10-1:2015由国际电工委员会 IX-IEC 发布于 2015-09。
IEC 60079-10-1:2015 在中国标准分类中归属于: C67 工厂防火防爆安全技术,在国际标准分类中归属于: 29.260.20 易爆环境用电气设备。
防爆危险区域划分的主要标准依据:GB3836.14 爆炸性气体环境用电气设备 第14部分 危险场所分类GB12476.3 可燃性粉尘环境用电气设备 第3部分 存在或可能存在可燃性粉尘的场所分类 具有潜在爆炸性危险的工业领域:石油/天然气开采炼油和化工企业燃油/燃气充装站制药业气体管线和输配站分析实验室表面喷涂工业印刷工业电子器件制造业地下煤矿工业污水处理厂医院手术室防爆的基本方法危险区的电气设备的火花和热效应是引起火灾和爆炸的主要因素...
在网站上的产品信息上经常看到防爆产品的适用环境里这样写的“适用于1区、2区危险场所; ⅡA 、ⅡB类爆炸性气体环境” 其中IIA、IIB类爆炸性气体混合物已经介绍过了。现在介绍一下爆炸性气体环境0区、1区、2区的划分。我国对爆炸性危险场所的划分采用与IEC等效的方法。...
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号