This part of IEC 60099 provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure - rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex J, some aspects regarding the old type of SiC gapped arresters are discussed. Surge arrester residual voltage is a major parameter to which most users have paid a lot of attention to when selecting the type and rating. Typical maximum residual voltages are given in Annex F. It is likely, however, that for some systems, or in some countries, the requirements on system reliability and design are sufficiently uniform, so that the recommendations of the present standard may lead to the definition of narrow ranges of arresters. The user of surge arresters will, in that case, not be required to apply the whole process introduced here to any new installation and the selection of characteristics resulting from prior practice may be continued. Annexes H and I present comparisons and calculations between old line discharge classification and new charge classification.

IEC 60099-5-2018由国际电工委员会 IX-IEC 发布于 2018-0101。

IEC 60099-5-2018 在中国标准分类中归属于: K49 避雷器,在国际标准分类中归属于: 29.120.50 熔断器和其他过载保护装置。

IEC 60099-5-2018 发布之时,引用了标准

  • IEC 60071-1-2006 绝缘配合.第1部分:定义、原则和规则*2006-01-01 更新
  • IEC 60071-1 AMD 1-2010 绝缘配合.第1部分:定义、原理和规则.修改件1*2010-01-01 更新
  • IEC 60071-2-1996 绝缘配合 第2部分:应用指南*1996-12-01 更新
  • IEC/TR 60071-4-2004 绝缘配合.第4部分:绝缘配合的计算指南和电子网络模拟*2004-06-01 更新
  • IEC 60099-4-2014 避雷器.第4部分:交流电系统用无间隙金属氧化物避雷器*2014-06-01 更新
  • IEC 60099-6-2002 避雷器.第6部分:额定电压等于或低于52kV的含有串联及并联间隙结构的避雷器*2002-08-01 更新
  • IEC 60099-8-2011 电涌放电器.第8部分:高于1 kV的直流系统的高架输电和配电用带有外部串联火花间隙(EGLA)的金属氧化物电涌放电器*2011-01-01 更新
  • IEC 60507-2013 交流电流系统用高压陶瓷和玻璃绝缘子的人工污染度试验*2013-12-01 更新
  • IEC/TS 60815-1-2008 污染条件下用高压绝缘子的选择和定尺寸.第1部分:定义、信息和一般原理*2008-10-01 更新
  • IEC 62271-200-2011 高压开关设备和控制设备.第200部分:为使额定电压大于1 kV小于等于52 kV而采用的交流铁壳开关设备和控制设备*2011-10-01 更新
  • IEC 62271-203-2011 高压开关设备和控制设备.第203部分:额定电压超过52 kV的气体绝缘金属壳开关装置*2011-09-01 更新

* 在 IEC 60099-5-2018 发布之后有更新,请注意新发布标准的变化。

IEC 60099-5-2018的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 60099-5-2018 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC 60099-5-2018
发布日期
1970年01月
实施日期
废止日期
中国标准分类号
K49
国际标准分类号
29.120.50;29.240.10
发布单位
IX-IEC
引用标准
IEC 60071-1-2006 IEC 60071-1 AMD 1-2010 IEC 60071-2-1996 IEC/TR 60071-4-2004 IEC 60099-4-2014 IEC 60099-6-2002 IEC 60099-8-2011 IEC 60507-2013 IEC/TS 60815-1-2008 IEC 62271-200-2011 IEC 62271-203-2011
被代替标准
IEC 37/437/FDIS-2017 IEC 60099-5-2013
适用范围
This part of IEC 60099 provides information, guidance, and recommendations for the selection and application of surge arresters to be used in three-phase systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel gapped structure - rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge arresters with external series gap for overhead transmission and distribution lines (EGLA) as defined in IEC 60099-8. In Annex J, some aspects regarding the old type of SiC gapped arresters are discussed. Surge arrester residual voltage is a major parameter to which most users have paid a lot of attention to when selecting the type and rating. Typical maximum residual voltages are given in Annex F. It is likely, however, that for some systems, or in some countries, the requirements on system reliability and design are sufficiently uniform, so that the recommendations of the present standard may lead to the definition of narrow ranges of arresters. The user of surge arresters will, in that case, not be required to apply the whole process introduced here to any new installation and the selection of characteristics resulting from prior practice may be continued. Annexes H and I present comparisons and calculations between old line discharge classification and new charge classification.

IEC 60099-5-2018系列标准

IEC 60099-1 AMD 1-1999 避雷器 第1部分:交流系统用有间隙阀式避雷器 修改件1 IEC 60099-1 Edition 3.1-1999 电涌放电器.第1部分:交流系统用非线性电阻型间隙式电涌放电器 IEC 60099-1-1991 避雷器 第1部分:交流系统用有间隙阀式避雷器 IEC 60099-2-1962 避雷器.第2部分:排气式避雷器 IEC 60099-4 AMD 1-2006 避雷器.第4部分:交流电系统用无间隙金属氧化物避雷器.修改件1 IEC 60099-4 AMD 2-2009 避雷器.第4部分:交流电系统用无间隙金属氧化物避雷器.修改件2 IEC 60099-4 Edition 1.1-1998 电涌放电器.第4部分:没有交流系统间隙的金属氧电涌放电器 IEC 60099-4 Edition 2.1-2006 电涌制动器.第4部分:a.c.系无缝金属氧化物的电涌制动器 IEC 60099-4 Edition 2.2-2009 避雷器.第4部分:交流电系统用无间隙金属氧化物避雷器 IEC 60099-4-2014 避雷器.第4部分:交流电系统用无间隙金属氧化物避雷器 IEC 60099-4-2004/AMD1-2006 修改件1.电涌放电器.第4部分:交流系统用无间隙金属氧化物电涌放电器 IEC 60099-4-2004/AMD2-2009 修改件2.电涌放电器.第4部分:交流系统用无间隙金属氧化物电涌放电器 IEC 60099-5 AMD 1-1999 避雷器 第5部分:选择和应用建议 修改件1 IEC 60099-5 CORR 1-1996 避雷器.第5部分:选择和应用建议 IEC 60099-5 Edition 1.1-2000 电涌放电器.第5部分:选择和应用推荐规程 IEC 60099-6-2019 电涌放电器第6部分:含有串联和并联间隙结构的电涌放电器52kv及以下系统电压 IEC 60099-8-2017 IEC 60099-8-2017 IEC 60099-9-2014 避雷装置. 第9部分: HVDC换流站无间隙金属氧化物避雷装置