IEC TS 62782-2016
光伏 (PV) 组件. 循环 (动态) 机械负荷试验

Photovoltaic (PV) modules - Cyclic (dynamic) mechanical load testing


IEC TS 62782-2016 发布历史

This technical specification provides a test method for performing a cyclic (dynamic) mechanical load test in which the module is supported at the design support points and a uniform load normal to the module surface is cycled in alternating negative and positive directions. This test may be utilized to evaluate if components within the module including solar cells, interconnect ribbons and/or electrical bonds within the module are susceptible to breakage or if edge seals are likely to fail due to the mechanical stresses encountered during installation and operation. This test can be performed at any module temperature within the normal operating temperature range. Since the results have been determined to depend on the module temperature during the application of the load it is critical to maintain the module at a constant temperature during the performance of this test. This technical specification has historically been applied to rigid modules. It cannot be applied to flexible modules unless they are designed to be mounted in a rigid manner. In which case, the cyclic (dynamic) mechanical load test can be applied to the flexible module in its rigid mounting system. This test has been written as a standalone technical specification, but it is likely to be used in conjunction with other test standards. Typically, this test itself will not result in power loss, but when followed by additional stress tests like thermal cycling and humidity freeze, the damage done by the mechanical cycling results in power loss that would not have occurred due only to the thermal cycling and humidity freeze tests. For example, the transportation testing procedure (IEC 62759) includes the requirements for such a cyclic (dynamic) mechanical load test followed by 50 thermal cycles and 10 humidity freeze cycles.

IEC TS 62782-2016由国际电工委员会 IX-IEC 发布于 2016-03。

IEC TS 62782-2016 在中国标准分类中归属于: F12 太阳能,在国际标准分类中归属于: 27.160 太阳能工程。

IEC TS 62782-2016 发布之时,引用了标准

  • IEC 61215-1-2016 Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 1: Test requirements (Edition 1.0)
  • IEC 61215-2-2016 Terrestrial photovoltaic (PV) modules – Design qualification and type approval – Part 2: Test procedures (Edition 1.0)
  • ISO/IEC 17025-2005 检测和校准实验室能力的一般要求

IEC TS 62782-2016的历代版本如下:

  • 2016年03月 IEC TS 62782-2016 光伏 (PV) 组件. 循环 (动态) 机械负荷试验

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC TS 62782-2016 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
IEC TS 62782-2016
发布日期
2016年03月
实施日期
废止日期
中国标准分类号
F12
国际标准分类号
27.160
发布单位
国际电工委员会
引用标准
IEC/TS 60904-12 IEC/TS 60904-13 IEC 61215-1-2016 IEC 61215-2-2016 IEC/TS 61836-2007 ISO/IEC 17025-2005
被代替标准
IEC 82/971/DTS-2015
适用范围
This technical specification provides a test method for performing a cyclic (dynamic) mechanical load test in which the module is supported at the design support points and a uniform load normal to the module surface is cycled in alternating negative and positive directions. This test may be utilized to evaluate if components within the module including solar cells, interconnect ribbons and/or electrical bonds within the module are susceptible to breakage or if edge seals are likely to fail due to the mechanical stresses encountered during installation and operation. This test can be performed at any module temperature within the normal operating temperature range. Since the results have been determined to depend on the module temperature during the application of the load it is critical to maintain the module at a constant temperature during the performance of this test. This technical specification has historically been applied to rigid modules. It cannot be applied to flexible modules unless they are designed to be mounted in a rigid manner. In which case, the cyclic (dynamic) mechanical load test can be applied to the flexible module in its rigid mounting system. This test has been written as a standalone technical specification, but it is likely to be used in conjunction with other test standards. Typically, this test itself will not result in power loss, but when followed by additional stress tests like thermal cycling and humidity freeze, the damage done by the mechanical cycling results in power loss that would not have occurred due only to the thermal cycling and humidity freeze tests. For example, the transportation testing procedure (IEC 62759) includes the requirements for such a cyclic (dynamic) mechanical load test followed by 50 thermal cycles and 10 humidity freeze cycles.