ZH

RU

ES

Portable Laser Rangefinder

Portable Laser Rangefinder, Total:41 items.

In the international standard classification, Portable Laser Rangefinder involves: Optoelectronics. Laser equipment, Machine tool systems, Linear and angular measurements, Optics and optical measurements, Nuclear energy engineering, Road engineering, Geology. Meteorology. Hydrology, Radiation measurements, Radiation protection, Analytical chemistry.


Group Standards of the People's Republic of China, Portable Laser Rangefinder

Professional Standard - Machinery, Portable Laser Rangefinder

Professional Standard - Nuclear Industry, Portable Laser Rangefinder

  • EJ/T 684-1992 Portable source excited X-ray fluorescence analyzer

National Metrological Verification Regulations of the People's Republic of China, Portable Laser Rangefinder

  • JJG 966-2001 Verification Regulation of Hand-held Laser Distance Meter
  • JJG 966-2010 Verification Regulation of Hand-held Laser Distance Meters

Professional Standard - Traffic, Portable Laser Rangefinder

  • JT/T 841-2012 Front-insert type auto deflectometer with laser range meter

Anhui Provincial Standard of the People's Republic of China, Portable Laser Rangefinder

Professional Standard - Ocean, Portable Laser Rangefinder

  • HY/T 0337-2022 On-the-spot comparative measurement of float type tide gauge and laser distance measurement method

Association Francaise de Normalisation, Portable Laser Rangefinder

  • NF C19-107*NF EN 62363:2011 Radiation protection instrumentation - Portable photon contamination meters and monitors.
  • NF EN 62363:2011 Instrumentation pour la radioprotection - Appareils portables de mesure et de surveillance de la contamination par des photons
  • NF EN 62533:2016 Instrumentation pour la radioprotection - Instruments portables de haute sensibilité pour la détection photonique de matières radioactives
  • NF EN ISO 11553-3:2013 Sécurité des machines - Machines à laser - Partie 3 : méthodes de mesure et de réduction du bruit des machines à laser, des dispositifs de traitement portatifs et des équipements auxiliaires connexes (classe de précision 2)
  • NF EN 16424:2014 Caractérisation des déchets - Méthode de dépistage pour la détermination de la composition élémentaire au moyen d'analyseurs portables de fluorescence X

General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China, Portable Laser Rangefinder

  • GB/T 29788-2013 Radiation protection instrumentation.Portable photon contamination meters and monitors

Fujian Provincial Standard of the People's Republic of China, Portable Laser Rangefinder

  • JJF(闽)1085-2018 Calibration Specification for Portable Raman spectrum fast detection instruments
  • DB35/T 1564-2016 Technical Requirements for Portable Rapid Raman Spectroscopy Detector

中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会, Portable Laser Rangefinder

  • GB/T 35734-2017 Portable tube-excited X-ray fluorescence analysis equipment-Classification, safety requirements and test

Danish Standards Foundation, Portable Laser Rangefinder

  • DS/EN 62363:2011 Radiation protection instrumentation - Portable photon contamination meters and monitors

European Committee for Electrotechnical Standardization(CENELEC), Portable Laser Rangefinder

  • EN 62363:2011 Radiation protection instrumentation - Portable photon contamination meters and monitors

RO-ASRO, Portable Laser Rangefinder

  • STAS SR CEI 1018-1995 High range beta and photon dose and dose rate portable instruments for emerpency radiation protection purposes

British Standards Institution (BSI), Portable Laser Rangefinder

  • BS EN 62363:2011 Radiation protection instrumentation. Portable photon contamination meters and monitors
  • BS ISO 16331-1:2017 Tracked Changes. Optics and optical instruments. Laboratory procedures for testing surveying and construction instruments. Performance of handheld laser distance meters
  • BS IEC 61017:2016 Radiation protection instrumentation. Transportable, mobile or installed equipment to measure photon radiation for environmental monitoring

International Electrotechnical Commission (IEC), Portable Laser Rangefinder

  • IEC 62363:2008 Radiation protection instrumentation - Portable photon contamination meters and monitors
  • IEC 61239:1993 Nuclear instrumentation; portable gamma radiation meters and spectrometers used for prospecting; definitions, requirements and calibration
  • IEC 62495:2011 Nuclear instrumentation - Portable X-ray fluorescence analysis equipment utilizing a miniature X-ray tube

German Institute for Standardization, Portable Laser Rangefinder

  • DIN ISO 16331-1:2020-09 Optics and optical instruments - Laboratory procedures for testing surveying and construction instruments - Part 1: Performance of handheld laser distance meters (ISO 16331-1:2017)
  • DIN ISO 16331-1:2020 Optics and optical instruments - Laboratory procedures for testing surveying and construction instruments - Part 1: Performance of handheld laser distance meters (ISO 16331-1:2017)

Japanese Industrial Standards Committee (JISC), Portable Laser Rangefinder

  • JIS Z 4333:1990 Portable photon ambient dose equivalent ratemeters for radiation protection
  • JIS Z 4333:2006 Portable photon ambient dose equivalent rate meters for use in radiation protection
  • JIS Z 4333 AMD 1:2001 Portable photon ambient dose equivalent ratemeters for radiation protection (Amendment 1)

Lithuanian Standards Office , Portable Laser Rangefinder

  • LST EN 62363-2012 Radiation protection instrumentation - Portable photon contamination meters and monitors (IEC 62363:2008, modified)

American Society for Testing and Materials (ASTM), Portable Laser Rangefinder

  • ASTM E1696-15(2022) Standard Test Method for Field Measurement of Raised Retroreflective Pavement Markers Using a Portable Retroreflectometer
  • ASTM E2540-16(2022) Standard Test Method for Measurement of Retroreflective Signs Using a Portable Retroreflectometer at a 0.5 Degree Observation Angle
  • ASTM E1709-16(2022) Standard Test Method for Measurement of Retroreflective Signs Using a Portable Retroreflectometer at a 0.2 Degree Observation Angle
  • ASTM E2120-10 Standard Practice for Performance Evaluation of the Portable X-Ray Fluorescence Spectrometer for the Measurement of Lead in Paint Films
  • ASTM E2120-00 Standard Practice for the Performance Evaluation of the Portable X-Ray Fluorescence Spectrometer for the Measurement of Lead in Paint Films

SE-SIS, Portable Laser Rangefinder

  • SIS SS-IEC 1018:1992 Nuclear instrumentation - High range beta andphoton dose and dose r?te portable instruments for emergency radiation protection purposes




Copyright ©2007-2023 ANTPEDIA, All Rights Reserved