ZH

RU

ES

Out-of-roundness measurement method

Out-of-roundness measurement method, Total:499 items.

In the international standard classification, Out-of-roundness measurement method involves: Linear and angular measurements, Tyres, Non-ferrous metals, Burners. Boilers, Cutting tools, Air quality, Wood, sawlogs and sawn timber, Electricity. Magnetism. Electrical and magnetic measurements, Optoelectronics. Laser equipment, Corrosion of metals, Iron and steel products, Dentistry, Road engineering, Metrology and measurement in general, Bearings, Insulating materials, Electrical wires and cables, Farming and forestry, Quality, Measurement of volume, mass, density, viscosity, Terminology (principles and coordination), Measurement of fluid flow, Tobacco, tobacco products and related equipment, Physics. Chemistry, Soil quality. Pedology, Glass, Woodworking equipment, Electronic display devices, Electronic tubes, Products of the textile industry, Thermodynamics and temperature measurements, Testing of metals, Geology. Meteorology. Hydrology, Water quality, Fertilizers, Electromagnetic compatibility (EMC), Analytical chemistry, Plastics, Optics and optical measurements, Sports equipment and facilities, Products of the chemical industry, Earthworks. Excavations. Foundation construction. Underground works, Welding, brazing and soldering, Cork and cork products, Lighting, Paint ingredients, Construction materials, Beverages, Inorganic chemicals, Gears, Wood technology processes, Leather technology, Environmental protection, Cereals, pulses and derived products, Road vehicle systems, Ferrous metals, Installations in buildings, Shipbuilding and marine structures in general, Radiation protection, Rotating machinery, Hand-held tools, Shafts and couplings, Resistors, Petroleum products in general, Powder metallurgy, Protection against fire, Radiation measurements, Audio, video and audiovisual engineering, Power stations in general, Fibre optic communications, Pulps, Paper and board, Elements of buildings, External water conveyance systems, Semiconducting materials, Pharmaceutics.


American Society of Mechanical Engineers (ASME), Out-of-roundness measurement method

British Standards Institution (BSI), Out-of-roundness measurement method

  • BS 3730-3:1982 Assessment of departures from roundness - Methods for determining departures from roundness using two- and three-point measurement
  • ISO/IEC GUIDE 98-3:2008/Suppl.1:2008 Uncertainty of measurement - Guide to the expression of uncertainty in measurement (GUM:1995). Propagation of distributions using a Monte Carlo method
  • BS 6740:1987 Method for determining departures from roundness by measuring variations in radius
  • BS 1042-2.2:1983 Measurement of fluid flow in closed conduits. Velocity area methods. Method of measurement of velocity at one point of a conduit of circular cross section
  • PD ISO/TR 13587:2012 Three statistical approaches for the assessment and interpretation of measurement uncertainty
  • BS DD ISO/TS 15530-4:2008 Geometrical product specifications (GPS). Coordinate measuring machines (CMM). Technique for determining the uncertainty of measurement. Evaluating task-specific measurement uncertainty using simulation
  • BS EN 55016-4-2:2011+A2:2018 Specification for radio disturbance and immunity measuring apparatus and methods. Uncertainties, statistics and limit modelling. Measurement instrumentation uncertainty
  • BS EN 1309-2:2006 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules
  • PD ISO/TR 20461:2001 Determination of uncertainty for volume measurements made using the gravimetric method
  • BS 1715-2.11:1989 Analysis of soaps. Quantitative test methods. Method for determination of ethanol-insoluble matter content
  • BS EN ISO 9455-1:2022 Soft soldering fluxes. Test methods - Determination of non-volatile matter, gravimetric method
  • BS EN 55016-4-2:2004 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Uncertainty in EMC measurements
  • BS 1042 Sec.2.3:1984 Measurement of fluid flow in closed conduits. Velocity area methods. Methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes
  • BS ISO 5725-4:2020 Accuracy (trueness and precision) of measurement methods and results - Basic methods for the determination of the trueness of a standard measurement method
  • BS ISO 5725-5:1998 Accuracy (trueness and precision) of measurement methods and results - Alternative methods for the determination of the precision of a standard measurement method
  • BS ISO 5725-4:1995 Accuracy (trueness and precision) of measurement methods and results - Basic methods for the determination of the trueness of a standard measurement method
  • BS ISO 7194:2008 Measurement of fluid flow in closed conduits - Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot statics tubes
  • BS ISO 9697:2015 Water quality. Gross beta activity in non-saline water. Test method using thick source
  • BS ISO 5725-3:1995 Accuracy (trueness and precision) of measurement methods and results. Intermediate measures of the precision of a standard measurement method
  • BS 6861-1:1987 Mechanical vibration - Balance quality requirements of rigid rotors - Method for determination of permissible residual unbalance
  • 16/30339603 DC BS EN 55016-4-2. Specification for radio disturbance and immunity measuring apparatus and methods. Part 4-2. Uncertainties, statistics and limit modelling. Measurement instrumentation uncertainty
  • BS EN ISO 14956:2002 Air quality. Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
  • BS ISO 9696:2007 Water quality - Measurement of gross alpha activity in non-saline water - Thick source method
  • BS ISO 9697:2008 Water quality - Measurement of gross beta activity in non-saline water - Thick source method
  • PD ISO/TR 16494-2:2019 Heat recovery ventilators and energy recovery ventilators. Method of test for performance. Assessment of measurement uncertainty of performance parameters
  • BS EN 55016-2-3:2010+A1:2010 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Radiated disturbance measurements
  • BS EN 55016-2-1:2009+A1:2011 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Conducted disturbance measurements
  • BS EN 55016-2-1:2009+A2:2013 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Conducted disturbance measurements
  • BS EN 55016-2-1:2014 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Conducted disturbance measurements
  • BS EN 60793-1-22:2002 Optical fibres - Measurement methods and test procedures - Length measurement - Section 22: Length measurement methods
  • BS EN 1309-3:2018 Round and sawn timber. Methods of measurements. Features and biological degradations
  • BS ISO 1088:2007 Hydrometry. Velocity-area methods using current-meters. Collection and processing of data for determination of uncertainties in flow measurement
  • 16/30339607 DC BS EN 55016-4-2 AMD2. Specification for radio disturbance and immunity measuring apparatus and methods. Part 4-2. Uncertainties, statistics and limit modelling. Measurement instrumentation uncertainty
  • 16/30337901 DC BS EN 55016-4-2 AMD2. Specification for radio disturbance and immunity measuring apparatus and methods. Part 4-2. Uncertainties, statistics and limit modelling. Measurement instrumentation uncertainty
  • BS EN 55016-2-2:2005 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity - Measurement of disturbance power
  • BS EN 55016-2-2:2011 Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Measurement of disturbance power
  • BS 1042 Sec.2.2:1983 Measurement of fluid flow in closed conduits. Velocity area methods. Method of measurement of velocity at one point of a conduit of circular cross section
  • BS EN 14625:2005 Ambient air quality - Standard method for the measurement of the concentration of ozone by ultraviolet photometry
  • BS EN 55016-2-1:2014+A1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity. Conducted disturbance measurements
  • BS EN 55016-2-3:2017+A1:2019 Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity. Radiated disturbance measurements

CZ-CSN, Out-of-roundness measurement method

  • CSN 01 4423-1987 Methods of measurement of roundness deviations
  • CSN 35 8572-1982 Television picture tubes. Measuring method of sereen luminance and non-uniformity of sereen luminance
  • CSN 50 0318-1961 Paper testing methods —Opacity of páper
  • CSN 25 7509-1980 Vortical cylindrical tanks. Calibration by eometrical methods
  • CSN 20 0300 Cast.16-1984 Measurements of geometrical accuracy of machine tools. Measuring methods. Di-mensional stability of cylindrical test workpieces of the samé series
  • CSN 20 0300 Cast.13-1985 Measuiements of geometrical accuracyof machine toolsMethods of peripheral runout
  • CSN 20 0300 Cast.14-1984 Measurements of geometrical accuracy of machine tools. Measuring methods. Axial run-out
  • CSN 01 4431-1987 Methods of mcasuremcnl of parallclism devialoris
  • CSN 20 0300 Cast.3-1984 Measurements of geometrlcal accuracy oí machlne tools Methods for roundes measurement of test workpiece
  • CSN 20 0300 Cast.18-1985 Measurements of geometrical accuracy of machine tools. Measuring methods Coaxiality
  • CSN 20 0300 Cast.27-1986 Measurements of geometrical accuracy ofmachine tools.Methods of measurement of variation of

General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China, Out-of-roundness measurement method

  • GB/T 30198-2013 Test method for run-out of motor vehicle tyres
  • GB/T 7235-1987 Methods for the assessment of departure from roundness--Measurement of variations in radius
  • GB/T 32324-2015 Rolling bearings.Methods for the measurement and assessment of departure from roundness and waviness
  • GB/T 11605-1989 Methods of humidity measurement
  • GB/T 10247-2008 Methods of viscosity measurement
  • GB/T 11605-2005 Methods of humidity measurement
  • GB/T 17899-1999 Method of pitting potential measurement for stainless steels
  • GB/T 2441.6-2001 Determination of urea Determination of water insolution matter content Weight method
  • GB/T 6113.402-2022 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-2:Uncertainties,statistics and limit modelling—Measurement instrumentation uncertainty
  • GB/T 6113.402-2006 Specification for radio disturbance and immunity measuring apparatus and methods.Part 4-2: Uncertainties, statistics and limit modelling.Measurement instrumentation Uncertainty
  • GB/T 7193.1-1987 Unsaturated polyester resin determination of viscosity
  • GB/T 7235-2004 Geometrical Product Specifications(GPS)Methods for the assessment of departure from roundness Measurement of variations in radius
  • GB/T 14625.1-1993 Basketball, football, volleyball, handball. The measurement of roundness
  • GB/T 31225-2014 Test method for the thickness of silicon oxide on Si substrate by ellipsometer
  • GB/T 2381-1994 Determination of content of insoluble matters in dyestuffs
  • GB/T 14453-1993 Metallic materials. Standard test method for the elastic modulus at high temperature. The method of disc. Vibrator
  • GB/T 8158.8-1987 Methods for chemical analysis of sodium fluoride--The gravimetric method for the determination of water-insoluble matter
  • GB/Z 6113.401-2007 Specification for radio disturbance and immunity measuring apparatus and methods.Part 4-1:Uncertainties,statistics and limit modelling.Uncertainties in standardized EMC tests
  • GB/Z 6113.401-2018 Specification for radio disturbance and immunity measuring apparatus and methods.Part 4-1:Uncertainties,statistics and limit modelling.Uncertainties in standardized EMC tests
  • GB/T 6379.3-2012 Accuracy(trueness and precision) of measurement methods and results.Part 3:Intermediate measures of the precision of a standard measurement method
  • GB/T 2441.6-2010 Determination of urea-Part 6:Water insoluble matter content-Weight method
  • GB/T 17952.1-2000 Hand-held electric mains voltage operated circular saws-Methods for measuring the performance
  • GB/T 14625.1-2008 Test methods for basketball,football,volleyball and handball- Part 1:Measurement of roundness
  • GB/T 7193.3-1987 Unsaturated polyester resin--Determination of solid content
  • GB/T 6379.4-2006 Accuracy(trueness and precision) of measurement methods and results-Part 4:Basic methods for the determination of the trueness of a standard measurement method
  • GB/T 5124.2-1985 Methods for chemical analysis of hardmetals--The gravimetric method for the determination of free (insoluble) carbon content
  • GB/T 2441.5-2001 Determination of Urea Determination of alkalinity titrimetric method
  • GB/T 15609-1995 Methods of measuring the chromaticity of colour television
  • GB/T 25836-2010 Rapid determination method of micro-hardness
  • GB/Z 24987-2010 Paper,board and pulps- Estimation of uncertainty for test methods
  • GB/T 13863-2011 Test methods for laser radiation power and its instability
  • GB/T 6379.5-2006 Accuracy (trueness and precision)of measurement methods and results-Part 5:alternative methods for the determination of the precision of a standard measurement method
  • GB/T 6113.204-2008 Specification for radio disturbance and immunity measuring apparatus and methods.Part 2-4:Methods of measurement of disturbances and immunity.Immunity measurements
  • GB/T 1954-1980 Determination of the welding seam iron element content in chromium,nickel austenitic stainless steel
  • GB/T 1954-2008 Methods of measurement for ferrite content in austenitic Cr-Ni stainless steel weld metals
  • GB/T 5124.2-2008 Methods for chemical analysis of hardmetals.Determination of insoluble (free) carbon content.Gravimetric method
  • GB/Z 6113.405-2010 Specification for radio disturbance and immunity measuring apparatus and methods.Part 4-5:Uncertainties,statistics and limit modelling.Conditions for the use of alternative test methods

Japanese Industrial Standards Committee (JISC), Out-of-roundness measurement method

Professional Standard - Aerospace, Out-of-roundness measurement method

  • QJ 3194-2004 Measuring Method of Large Size Roundness Error
  • QJ 3002-1998 Measuring method of position degree of large-size circular distribution holes
  • QJ 1794-1989 Uncertainty Estimation Method for Steady-state Flow Measurement of Liquid Rocket Engine
  • QJ 1229-1987 Estimation Method of Measurement Uncertainty of Steady State Parameters of Liquid Rocket Engine
  • QJ 1789-1989 Uncertainty Estimation Method for Steady State Thrust Measurement of Liquid Rocket Engine
  • QJ 1790-1989 Uncertainty Estimation Method for Steady-state Pressure Measurement of Liquid Rocket Motor

Korean Agency for Technology and Standards (KATS), Out-of-roundness measurement method

  • KS D 0259-2012(2017) Methods of measurement of thickness,thickness variation and bow for silicon wafer
  • KS B ISO 4291-2014(2019) Methods for the assessement of depature from roundness — Measurement of variations in radius
  • KS B 0434-1980 Method of conical cup test
  • KS Q ISO TR 13587:2021 Three statistical approaches for the assessment and interpretation of measurement uncertainty
  • KS B 4070-2001(2011) Test methods for performance and accuracy of circular saw machines
  • KS B 4070-1981 Test methods for performance and accuracy of circular saw machines
  • KS A 0078-1999(2019) Humidity-Measurement methods
  • KS D 0238-2004 Method of pitting potential measurement for stainless steels
  • KS D 0238-2004(2019) Method of pitting potential measurement for stainless steels
  • KS D 0238-1982 Method of pitting potential measurement for stainless steels
  • KS B ISO 4292:2014 Methods for the assessment of departure from roundness — Measurement by two-and three-point methods
  • KS B ISO 4292:2004 Methods for the assessment of departure from roundness-Measurement by two-and three-point methods
  • KS B ISO 4291:2004 Methods for the assessment of departure from roundness-Measurement of variations in radius
  • KS B ISO 4291:2014 Methods for the assessement of depature from roundness — Measurement of variations in radius
  • KS C 1606-1991(2016) Electrica1 Methods of Temperature Measurements
  • KS D 0247-2004 Method for making anodic polarization measurement for stainless steels
  • KS D 0247-1984 Method for making anodic polarization measurement for stainless steels
  • KS F 2311-2001 Test method for soil density by the sand replacement method
  • KS F 2199-2001 Determination of moisture content of wood
  • KS F 2308-2006 Test method for density of soil particles
  • KS A 0531-2016(2021) Viscosity of liquid-Methods of measurement
  • KS F 2308-1986 Test method for density of soil particles
  • KS F 2478-2013(2018) Test method measuring changes in height of cylindrical specimens from hydraulic-cement mortar
  • KS A ISO 5725-5-2012(2017) Accuracy(trueness and precision) of measurement methods and results-Part 5:Alternative methods for the determination of the precision of a standard measurement method
  • KS F 2010-2013(2018) Method of measurements for flow discharge in open channels?Velocity-area methods
  • KS A ISO 5725-4:2021 Accuracy(trueness and precision) of measurement methods and results — Part 4: Basic methods for the determination of the trueness of a standard measurement method
  • KS C 7614-1987 Photometric measurements on incandescent lamps used for photometric standards
  • KS A ISO 5725-3-2012(2022) Accuracy(trueness and precision) of measurement methods and results-Part 3:lntermediate measures of the precision of a standard measurement method
  • KS A ISO 5725-3-2012(2017) Accuracy(trueness and precision) of measurement methods and results-Part 3:lntermediate measures of the precision of a standard measurement method
  • KS F 2208-2004 Method of bending test for wood
  • KS I 5004-2002 Method of sound level measurement for machine tools
  • KS A 0531-2016 Viscosity of liquid-Methods of measurement
  • KS F 2200-2000 Wood-based panels-Determination of density
  • KS C 1606-2021 Electrical methods of temperature measurements
  • KS L 2405-2006(2021) Method of measurement for specular glossiness
  • KS A ISO 5725-5-2012(2022) Accuracy(trueness and precision) of measurement methods and results-Part 5:Alternative methods for the determination of the precision of a standard measurement method
  • KS C IEC 61176-2003(2018)
  • KS C CISPR 16-2-4-2012 Specification for radio disturbance and immunity measuring apparatus and methods-Part 2-4:Methods of measurement of disturbance and immunity-Immunity measurements
  • KS I ISO 9696:2007 Water quality-Measurement of gross alpha activity in non-saline water-Thick source method
  • KS C 7613-1999 Methods of luminance measurements in lighting fields
  • KS K 0255-1999
  • KS L 2405-2006(2016) Method of measurement for specular glossiness
  • KS K ISO 9863:2002 MEASURING METHOD FOR THICKNESS OF GEOTEXTILE
  • KS C 7613-1982 Methods of luminance measurements in lighting fields
  • KS M ISO TR 24498:2008 Paper, board and pulps-Estimation of uncertainty for test methods
  • KS C CISPR 16-2-2013 Specification for radio disturbance and immunity measuring apparatus andmethods-Part 2:Methods of measurement of disturbances and immunity
  • KS B ISO 1088:2005 Liquid flow measurement in open channels-Velocity-area methods-Collection and processing of data for determination of errors in measurement
  • KS D 7130-2005(2020) Method of electrochemical potentiokinetic reactivation ratio measurement for stainless steels
  • KS C 9816-2-4-2017 Specification for radio disturbance and immunity measuring apparatus and methods — Part 2-4: Methods of measurement of disturbances and immunity — Immunity measurements
  • KS A ISO 5725-5:2012 Accuracy(trueness and precision) of measurement methods and results-Part 5:Alternative methods for the determination of the precision of a standard measurement method

Professional Standard - Electricity, Out-of-roundness measurement method

  • DL/T 1961-2019 Calculation Method of Flow Measurement Uncertainty in Thermal Power Plant

RU-GOST R, Out-of-roundness measurement method

  • GOST 3060-1986 Grinding wheels. Unbalanced masses and measurement method
  • GOST R 52117-2003 Round timber. Methods of measurements
  • GOST 32594-2013 Roundtimber. Methodsofmeasurements
  • GOST 21316.4-1975 Photocells. Method of measurement of sensitivity nenuniformity
  • GOST R 54365-2011 Round timber. Top diameter and taper method of volume measurement
  • GOST 14340.3-1969 Enamelled round wires. Methods of the flexibility test
  • GOST 21323-1975 Abrasive tool hardnees measurement by cone indentation
  • GOST 12037-1981 Seed of farm crops. Methods for determination of purity and seed lot impurity
  • GOST 34100.3.1-2017 Uncertainty of measurement. Part 3. Guide to the expression of uncertainty in measurement. Supplement 1. Propagation of distributions using a Monte Carlo method
  • GOST 14340.5-1978 Enamelled round wires. Method of bonding strength test
  • GOST 25024.4-1985 Character displays. Methods measuring brightness, luminous intensity, irregularity of brightness and irregularity of luminous intensity
  • GOST 21815.16-1986 Image intensifier and image converter tubes. Method of measuring the output brightness non- uniformity ratio
  • GOST 28753.2-1990 Textile threads. Method for determination of snarling tendency
  • GOST 14340.1-1974 Enamelled round wires. Method for measurement of wires diameters
  • GOST 21316.5-1975 Photocells. Method of instability measurement
  • GOST R 54500.3.1-2011 Uncertainty of measurement. Part 3. Guide to the expression of uncertainty in measurement. Supplement 1. Propagation of distributions using a Monte Carlo method
  • GOST R 56925-2016 Automobile roads and airfields. Uneveness measurement methods for base courses and pavements
  • GOST 8.605-2011 State system for ensuring the uniformity of measurements. State verification schedule for means of measuring of the ellipsometric angles
  • GOST 21059.1-1975 Picture tubes for TV. Methods for measurement of screen brightness and uniformity of screen brilliancy
  • GOST 17231-1978 Round timber and splitted timber. Methods for determination of moisture content
  • GOST 11612.3-1975 Photomultipliers. Measuring method of non-uniformity of light anode sensitivity over the photocatode area
  • GOST R ISO 9727-3-2010 Cylindrical cork stoppers. Methods for determination of physical properties. Part 3. Determination of humidity content
  • GOST R 53185-2008 Alcohol-free and low-alcoholic tonic beverages. Test methods
  • GOST 25024.5-1987 Character displays. Methods of measuring inherent brightness contrast and irregularity of inherent brightness contrast
  • GOST ISO 9727-3-2016 Cylindrical cork stoppers. Methods for determination of physical properties. Part 3. Determination of humidity content
  • GOST 11612.11-1985 Photomultipliers. Measuring method of instability
  • GOST 13586.5-1993 Grain. Method of moisture content determination
  • GOST 16755-1971 Cathode-ray receiver devices. Method for measurement of irregularity fluorescent screen brightness
  • GOST 24567-1981 Pneumatic tyres. Method for measurement of effective rolled circumference in road tests
  • GOST 21342.11-1976 Varistors. Method of measuring current asymmetry and voltage asymmetry
  • GOST 33768-2015 Method determination of kinematic viscosity and calculation of dynamic viscosity of transparent and opaque liquids
  • GOST 15139-1969 Plastics. Methods for the determination of density (mass density)
  • GOST R ISO 5725-4-2002 Accuracy (trueness and precision) of measurement methods and results. Part 4. Basic methods for the determination of the trueness of a standard measurement method
  • GOST EN 1236-2013 Fertilizers. Method of determination of bulk density without loose
  • GOST 21059.5-1976 Kinescopes for black-white and colour television. Measurement methods of chromacity and non-uniformity of screen glow chromacity
  • GOST 21970-2015 Unsaturated polyester resins. Methods for determination of maximum temperature during the setting

Association of German Mechanical Engineers, Out-of-roundness measurement method

  • VDI 2449 Blatt 3-2001 Measurement methods test criteria - General method for the determination of the uncertainty of calibratable measurement methods
  • VDI/VDE/DGQ/DKD 2622 Blatt 2-2015 Calibration of measuring equipment for electrical quantities - Methods for the determination of the uncertainty of measurement
  • VDI/VDE/DGQ/DKD 2622 Blatt 2-2003 Calibration of measuring means for electrical quantities - Methods for the determination of the measurement uncertainty
  • VDI/VDE/DGQ/DKD 2622 Blatt 2.1-2011 Calibration of measuring equipment for electrical quantities - Methods for the determination of measurement uncertainty - Notes to a practical approach
  • VDI/VDE 3514 Blatt 2-2013 Measurement of humidity - Methods of measurement
  • VDI 4219-2009 Determination of the uncertainty of emission measurements by use of discontinuous measurement methods
  • VDI/VDE 3511 Blatt 1-1996 Temperature measurement in industry - Principles and special methods of temperature measurement

AT-ON, Out-of-roundness measurement method

  • ONORM ISO 4292:1988 Methodsfor the assessment ofdeparture from roundness; measurement by two- and three-point methods
  • ONORM ISO 4291:1988 Methods for the assessment of departure from roundness; measurement of variations in radius
  • ONORM C 2525-1989 Measurement of coating thickness survey of methods

Instrument Society of America (ISA), Out-of-roundness measurement method

American Gear Manufacturers Association, Out-of-roundness measurement method

KR-KS, Out-of-roundness measurement method

  • KS B ISO 4292-2014 Methods for the assessment of departure from roundness — Measurement by two-and three-point methods
  • KS Q ISO TR 13587-2021 Three statistical approaches for the assessment and interpretation of measurement uncertainty
  • KS F 2478-2013(2023) Test method measuring changes in height of cylindrical specimens from hydraulic-cement mortar
  • KS A ISO 5725-4-2021 Accuracy(trueness and precision) of measurement methods and results — Part 4: Basic methods for the determination of the trueness of a standard measurement method
  • KS K ISO 9863-2002 MEASURING METHOD FOR THICKNESS OF GEOTEXTILE
  • KS E ISO 7194-1-2018(2023) Measurement of fluid flow in closed conduits — Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current meters or pitot static tubes
  • KS P ISO 13116-2017 Dentistry ─ Test Method for Determining Radio-Opacity of Materials

Association Francaise de Normalisation, Out-of-roundness measurement method

  • NF E10-104:1989 Dimensional measuring methods. Part 5 : cylindrical deviation.
  • NF ISO 19474:2018 Bois ronds - Caractéristiques visuelles - Méthodes de mesure
  • NF X31-501:1992 Qualité des sols - Méthodes physiques - Mesure de la masse volumique apparente d'un échantillon de sol non remanié - Méthode du cylindre.
  • NF ISO 13752:1998 Qualité de l'air - Évaluation de l'incertitude d'une méthode de mesurage sur site en utilisant une seconde méthode comme référence
  • FD ISO/TR 16153:2023 Détermination de l'incertitude de mesure pour les mesurages volumétriques des appareils volumétriques à piston au moyen de la méthode photométrique
  • NF B53-613:1997 Round and sawn timber. Method of measurement of features.
  • NF X10-113:1982 Determination of flowrate of fluids in closed conduits of circular cross-section. Method of velocity measurement at one point of the cross-section.
  • NF B53-614:1997 Round and sawn timber. Method of measurement of biological degrade.
  • NF X43-508*NF EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
  • XP S31-115-1:2019 Acoustics - Assessment method of measurement uncertainties in environment acoustics - Part 1 : influence of measuring instruments
  • NF X31-500*NF ISO 10573:1996 Soil quality. Determination of water content of the unsaturated zone. Neutron depth probe method.
  • NF H44-022:1986 Aerosols dispensers. Cylindrical containers. Definition and measuring method of the height of the cover seat.
  • NF B53-612-2*NF EN 1309-2:2006 Round and sawn timber - Method of measurement of dimensions - Part 2 : round timber - Requirements for measurement and volume calculation rules
  • NF EN 1309-2:2006 Bois ronds et bois sciés - Méthode de mesure des dimensions - Partie 2 : bois ronds - Exigences pour la mesure et les régles de calcul du volume
  • NF A06-555:2010 Steel - Determination of nitrogen content - Spectrophotometric method.
  • NF C91-016-4-2:2005 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2 : uncertainties, statistics and limit modelling - Incertainty in EMC measurements.
  • NF X06-041-4*NF ISO 5725-4:2020 Accuracy (trueness and precision) of measurement methods and results - Part 4 : basic methods for the determination of the trueness of a standard measurement method
  • NF X10-114:1993 Measurement of fluid flow in closed conduits. Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or pitot static tubes.
  • NF M60-815:2008 Water quality - Measurement of gross alpha activity in non-saline water - Thick source method.
  • NF M60-816:2008 Water quality - Measurement of gross beta activity in non-saline water - Thick source method.
  • NF EN ISO 748:2021 Hydrométrie - Mesurage du débit des écoulements à surface libre - Méthodes d'exploration du champ des vitesses utilisant le mesurage de la vitesse par point
  • NF ISO 5725-4:2020 Exactitude (justesse et fidélité) des résultats et méthodes de mesure - Partie 4 : méthodes de base pour la détermination de la justesse d'une méthode de mesure normalisée
  • NF EN 951:1999 Vantaux de portes - Méthode de mesure des hauteur, largeur, épaisseur et équerrage
  • NF C91-016-4-2*NF EN 55016-4-2:2012 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2 : uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • NF C91-016-4-2/A2*NF EN 55016-4-2/A2:2018 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2 : uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • NF X43-064*NF EN 14625:2013 Ambient air quality - Standard method for the measurement of the concentration of ozone by ultraviolet photometry

GOSTR, Out-of-roundness measurement method

  • GOST 34233.11-2017 Vessels and apparatus. Norms and methods of strength calculation. Method of strength calculation of shells and bottoms according to weld misalignment, angular misalignment and shell nonroundness

European Committee for Standardization (CEN), Out-of-roundness measurement method

  • EN ISO 13078:2013 Dentistry - Dental furnace - Test method for temperature measurement with separate thermocouple
  • EN 1309-2:2006 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules

American Society for Testing and Materials (ASTM), Out-of-roundness measurement method

  • ASTM E1364-95(2005) Standard Test Method for Measuring Road Roughness by Static Level Method
  • ASTM E1274-03(2017) Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM D1155-03 Standard Test Method for Roundness of Glass Spheres
  • ASTM D1155-89(1994)e1 Standard Test Method for Roundness of Glass Spheres
  • ASTM D1155-10(2020) Standard Test Method for Roundness of Glass Spheres
  • ASTM D1155-10(2015) Standard Test Method for Roundness of Glass Spheres
  • ASTM E2655-14 Standard Guide for Reporting Uncertainty of Test Results and Use of the Term Measurement Uncertainty in ASTM Test Methods
  • ASTM E1274-03 Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM E1274-88(1993)e1 Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM E1274-03(2008) Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM E1274-03(2012) Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM E1274-18 Standard Test Method for Measuring Pavement Roughness Using a Profilograph
  • ASTM F907-85(1992)e1 Test Method for Measurement of Rotational Acceleration of a Wafer for Photoresist Spin Coating
  • ASTM F907-85E01R92 Test Method for Measurement of Rotational Acceleration of a Wafer for Photoresist Spin Coating
  • ASTM D7366-08(2019) Standard Practice for Estimation of Measurement Uncertainty for Data from Regression-based Methods
  • ASTM D7466/D7466M-10(2015)e1 Standard Test Method for Measuring Asperity Height of Textured Geomembranes
  • ASTM E2655-14(2020) Standard Guide for Reporting Uncertainty of Test Results and Use of the Term Measurement Uncertainty in ASTM Test Methods
  • ASTM C1090/C1090M-23 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout
  • ASTM D4032-94 Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure
  • ASTM D4032-94(2001) Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure
  • ASTM D4032-08 Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure
  • ASTM D4032-08(2012) Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure
  • ASTM D4032-08(2016) Standard Test Method for Stiffness of Fabric by the Circular Bend Procedure
  • ASTM C1090-01(2005)e1 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens of Hydraulic-Cement Grout
  • ASTM C1090-01 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from Hydraulic-Cement Grout
  • ASTM C1090-96 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from Hydraulic-Cement Grout
  • ASTM D2664-95a Standard Test Method for Triaxial Compressive Strength of Undrained Rock Core Specimens Without Pore Pressure Measurements
  • ASTM D7971-15 Standard Guide for Measuring Roundness of Glass Spheres Using a Flowing Stream Digital Image Analyzer
  • ASTM D5716-95(2006) Standard Test Method for Measuring the Rate of Well Discharge by Circular Orifice Weir
  • ASTM F576-00 Standard Test Method for Measurement of Insulator Thickness and Refractive Index on Silicon Substrates by Ellipsometry
  • ASTM D2664-04 Standard Test Method for Triaxial Compressive Strength of Undrained Rock Core Specimens Without Pore Pressure Measurements
  • ASTM F640-07 Standard Test Methods for Determining Radiopacity for Medical Use
  • ASTM F640-12 Standard Test Methods for Determining Radiopacity for Medical Use
  • ASTM D2937-17 Standard Test Method for Density of Soil in Place by the Drive-Cylinder Method
  • ASTM D2937-17e1 Standard Test Method for Density of Soil in Place by the Drive-Cylinder Method
  • ASTM D2937-17e2 Standard Test Method for Field Determination of Soil Density by the Pushing Cylinder Method

Danish Standards Foundation, Out-of-roundness measurement method

  • DS/ISO 4291:1990 Methods for the assessment of departure from roundness — Measurement of variations in radius
  • DS/ISO 4292:1990 Methods for the assessment of departure from roundness - Measurement by two- and three-point methods
  • DS/ISO/TR 13587:2012 Three statistical approaches for the assessment and interpretation of measurement uncertainty
  • DS/EN 1310:2000 Round and sawn timber - Method of measurement of features
  • DS/EN 55016-4-2:2012 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • DS/ISO/TR 16153:2005 Piston-operated volumetric instruments - Determination of uncertainty for volume measurements made using the photometric method
  • DS/EN 1311:1998 Round and sawn timber - Method of measurement of biological degrade
  • DS/ISO 5725-3/Corr.1:2002 Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate measures of the precision of a standard measurement method
  • DS/CEN/CR 14377:2002 Air quality - Approach to uncertainty estimation for ambient air reference measurement methods
  • DS/EN 1309-2:2006 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules
  • DS/ISO 5725-5/Corr. 1:2005 Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method
  • DS/ISO 5725-5:2000 Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method
  • DS/EN 61176:1994 Hand-held electric mains voltage operated circular saws - Methods for measuring the performance
  • DS/EN 951:1999 Door leaves - Method for measurement of height, width, thickness and squareness
  • DS/EN 55016-2-4:2005 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements
  • DS/ISO 5725-3:1995 Accuracy (trueness and precision) of measurement methods and results- Part 3: Intermediate measures of the precision of a standard measurement method

AENOR, Out-of-roundness measurement method

  • UNE 82320:1995 METHODS FOR THE ASSESSMENT OF DEPARTURE FROM ROUNDNESS. MEASUREMENT OF VARIATIONS IN RADIUS.
  • UNE-EN 1310:1997 ROUND AND SAWN TIMBER. METHOD OF MEASUREMENT OF FEATURES.
  • UNE-EN 55016-4-2:2012 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • UNE-EN 55016-4-2:2012/A1:2014 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • UNE 400331:2003 IN Determination of uncertainty for volume measurements made using the gravimetric method.
  • UNE-EN 1311:1998 ROUND AND SAWN TIMBER. METHOD OF MEASUREMENT OF BIOLOGICAL DEGRADE.
  • UNE-CR 14377:2005 IN Air quality - Approach to uncertainty estimation for ambient air reference measurement methods
  • UNE-EN 1309-2:2007 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules
  • UNE 82009-3:1999 ACCURACY (TRUENESS AND PRECISION) OF MEASUREMENT METHODS AND RESULTS. PART 3: INTERMEDIATE MEASURES OF THE PRECISION OF A STANDARD MEASUREMENT METHOD.
  • UNE 82009-5:1999 ACCURACY (TRUENESS AND PRECISION) OF MEASUREMENT METHODS AND RESULTS. PART 5: ALTERNATIVE METHODS FOR THE DETERMINATION OF THE PRECISION OF A STANDARD MEASUREMENT METHOD.

International Telecommunication Union (ITU), Out-of-roundness measurement method

  • ITU-T R.4-1989 Methods for the Separate Measurements of the Degrees of Various Types of Telegraph Distortion - Telegraph Transmission (Study Group IX) 1 pp
  • ITU-T R.4 FRENCH-1988 METHODS FOR THE SEPARATE MEASUREMENTS OF THE DEGREES OF VARIOUS TYPES OF TELEGRAPH DISTORTION
  • ITU-T R.4 SPANISH-1988 METHODS FOR THE SEPARATE MEASUREMENTS OF THE DEGREES OF VARIOUS TYPES OF TELEGRAPH DISTORTION

SE-SIS, Out-of-roundness measurement method

  • SIS SS-ISO 4291:1991 Methods for the assessment of departure from roundness — Measurement of varia- tions in radius
  • SIS SS-ISO 4292:1991 Methods for the assessment of departure from roundness — Measurement by two- and three-point methods
  • SIS 13 61 03-1962 Method of test for 45-deg, 0-deg directional reflectance of opaque specimens

国家认证认可监督管理委员会, Out-of-roundness measurement method

  • RB/T 141-2018 Measurement uncertainty assessment in the field of chemical detection uses quality control and method validation data to assess uncertainty

International Organization for Standardization (ISO), Out-of-roundness measurement method

  • ISO/TR 20461:2000 Determination of uncertainty for volume measurements made using the gravimetric method
  • ISO/TR 20461:2023 Determination of uncertainty for volume measurements of a piston-operated volumetric apparatus using a gravimetric method
  • ISO 4292:1985 Methods for the assessment of departure from roundness; Measurement by two- and three-point methods
  • ISO 4291:1985 Methods for the assessement of departure from roundness; Measurement of variations in radius
  • ISO/TS 15530-4:2008 Geometrical Product Specifications (GPS) - Coordinate measuring machines (CMM): Technique for determining the uncertainty of measurement - Part 4: Evaluating task-specific measurement uncertainty using simulation
  • ISO 7194:2008 Measurement of fluid flow in closed conduits - Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes
  • ISO 13752:1998 Air quality - Assessment of uncertainty of a measurement method under field conditions using a second method as reference
  • ISO 13059:2011 Round timber - Requirements for the measurement of dimensions and methods for the determination of volume
  • ISO/AWI 5725-5 Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative methods for the determination of the precision of a standard measurement method
  • ISO/CD 5725-5:2023 Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative methods for the determination of the precision of a standard measurement method
  • ISO/TR 16153:2004 Piston-operated volumetric instruments - Determination of uncertainty for volume measurements made using the photometric method
  • ISO/TR 16153:2023 Determination of uncertainty for volume measurements of a piston-operated volumetric apparatus using a photometric method
  • ISO 9696:2007 Water quality - Measurement of gross alpha activity in non-saline water - Thick source method
  • ISO/TR 24498:2006 Paper, board and pulps - Estimation of uncertainty for test methods
  • ISO 1088:2007 Hydrometry - Velocity-area methods using current-meters - Collection and processing of data for determination of uncertainties in flow measurement
  • ISO/TR 20461:2000/cor 1:2008 Determination of uncertainty for volume measurements made using the gravimetric method; Technical Corrigendum 1

Group Standards of the People's Republic of China, Out-of-roundness measurement method

  • T/SMA 0007-2020 Evaluation Method of Measurement Uncertainty of Variable Head Water Flow Standard Device
  • T/GDCKCJH 044-2021 On-site test methods for diameter and roundness of expanded pipe
  • T/SSEA 0069-2020 Measuring method of bending degree of bar

TIA - Telecommunications Industry Association, Out-of-roundness measurement method

  • TIA/EIA-455-93-1993 FOTP-93 Test Method for Optical Fiber Cladding Diameter and Noncircularity by Noncontacting Michelson Interferometry

Professional Standard - Machinery, Out-of-roundness measurement method

  • JB/T 6642-2004 Rolling bearing parts-Methods for the measurement and assessment of departure from roundness and waviness
  • JB/T 5996-1992 Roundness measurement Assessment of accuracy of three-point measuring method and the measurement instrument used

National Metrological Technical Specifications of the People's Republic of China, Out-of-roundness measurement method

  • JJF(烟草) 2.2-2008 Evaluation of Uncertainty in Measurement for Parameter of Physical Characteristics of Cigarettes.Part 2: Circumference.Laser Method
  • JJF(烟草)2.2-2008 Evaluation of Uncertainty in Measurment for Parameter of Physical Characteristics of Cigarettes—Part 2:Circumference—Laser Method
  • JJF 1059.2-2012 Evaluating the Technical Specifications of Measurement Uncertainty by Monte Carlo Method

未注明发布机构, Out-of-roundness measurement method

  • BS 3730-3:1982(1999) Assessment of departures from roundness — Part 3 : Methods for determining departures from roundness using two - and three - point measurement
  • BS ISO 13752:1998(1999) Air quality — Assessment of uncertainty of a measurement method under field conditions using a second method as reference
  • BS ISO 5725-3:1994(2002) Accuracy (trueness and precision) of measurement methods and results — Part 3 : Intermediate measures of the precision of a standard measurement method
  • BS EN 55016-4-2:2011+A2:2018(2019) Specification for radio disturbance and immunity measuring apparatus and methods Part 4 - 2 : Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty

GB-REG, Out-of-roundness measurement method

PL-PKN, Out-of-roundness measurement method

  • PKN-ISO/IEC Guide 98-3/Suppl.1-2021-10 P Uncertainty of measurement -- Part 3: Guide to the expression of uncertainty in measurement (GUM:1995). Supplement 1: Propagation of distributions using a Monte Carlo method
  • PN C89082-04-1986 Unsaturated polyester resins Methods of testing Determination of yiscosity
  • PN T04840-07-1986 Camera tubes Method of measurement of white and black background non-uniformity
  • PN C89082-03-1986 Unsaturated polyester resins Methods of testing Determination of density (specific gravity)

Lithuanian Standards Office , Out-of-roundness measurement method

  • LST EN 1310-1998 Round and sawn timber - Method of measurement of features
  • LST EN 1310-1998/1K-2004 Round and sawn timber. Method of measurement of features
  • LST EN 1311-1998 Round and sawn timber - Method of measurement of biological degrade
  • LST EN 1311-1998/1K-2004 Round and sawn timber. Method of measurement of biological degrade
  • LST EN 1309-2-2006 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules
  • LST EN 951-2004 Door leaves - Method for measurement of height, width, thickness and squareness

German Institute for Standardization, Out-of-roundness measurement method

  • DIN EN 1310:1997 Round and sawn timber - Method of measurement of features; German version EN 1310:1997
  • DIN 5032-1:1999 Photometry - Part 1: Methods of measurement
  • DIN SPEC 1168:2010 Air quality - Approach to uncertainty estimation for ambient air reference measurement methods; German version CR 14377:2002
  • DIN EN 1309-2:2006 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules English version of DIN EN 1309-2:2006-06
  • DIN 53019-2:2001 Viscosimetry - Measurement of viscosities and flow curves by means of rotation viscosimeters - Part 2: Viscosimeter calibration and determination of the uncertainty of measurement
  • DIN EN ISO 13116:2015-03 Dentistry - Test Method for Determining Radio-Opacity of Materials (ISO 13116:2014); German version EN ISO 13116:2014
  • DIN EN 951:1999-05 Door leaves - Method for measurement of height, width, thickness and squareness; German version EN 951:1998
  • DIN ISO 5725-3:2003 Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate measures of the precision of a standard measurement method (ISO 5725-3:1994 including Technical Corrigendum 1:2001)
  • DIN SPEC 1168:2010-07 Air quality - Approach to uncertainty estimation for ambient air reference measurement methods; German version CR 14377:2002
  • DIN 52102:2013-10 Test methods for aggregates - Determination of dry bulk density by the cylinder method and calculation of the ratio of density
  • DIN ISO 13752:1999-01 Air quality - Assessment of the uncertainty of a measurement method under field conditions using a second method as reference (ISO 13752:1998)
  • DIN ISO 5725-3:2003-02 Accuracy (trueness and precision) of measurement methods and results - Part 3: Intermediate measures of the precision of a standard measurement method (ISO 5725-3:1994 including Technical Corrigendum 1:2001)
  • DIN EN 13036-7:2003-12 Road and airfield surface characteristics - Test methods - Part 7: Irregularity measurement of pavement courses: The straightedge test; German version EN 13036-7:2003
  • DIN ISO 5725-5:2002-11 Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method (ISO 5725-5:1998)
  • DIN EN 1309-2:2006-06 Round and sawn timber - Method of measurement of dimensions - Part 2: Round timber - Requirements for measurement and volume calculation rules; German version EN 1309-2:2006
  • DIN ISO 5725-5:2002 Accuracy (trueness and precision) of measurement methods and results - Part 5: Alternative methods for the determination of the precision of a standard measurement method (ISO 5725-5:1998)

IX-ISO/IEC, Out-of-roundness measurement method

  • ISO/IEC GUIDE 98-3-SP1:2008 Supplement 1 - Uncertainty of measurement - Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) - Propagation of distributions using a Monte Carlo method

Standard Association of Australia (SAA), Out-of-roundness measurement method

  • CISPR 16-4:2002 Specification for radio disturbance and immunity measuring apparatus and methods — Part 4: Uncertainty in EMC measurements
  • AS/NZS CISPR 16.4.1:2012
  • AS 3778.3.4:2022 Measurement of water flow in open channels, Part 3.4: Velocity-area methods — Collection and processing of data for determination of uncertainties in measurement (ISO 1088:2007, IDT)
  • AS/NZS CISPR 16.4.5:2013
  • AS 1289.6.4.1:1998 Methods of testing soils for engineering purposes - Soil strength and consolidation tests - Determination of compressive strength of a soil - Compressive strength of a specimen tested in undrained triaxial compression without measurement of pore water p
  • AS 1580.301.1:2005/Amdt 1:2006
  • AS 1289.6.4.2:1998 Methods of testing soils for engineering purposes - Soil strength and consolidation tests - Determination of compressive strength of a soil - Compressive strength of a saturated specimen tested in undrained triaxial compression with measurement of pore
  • AS/NZS CISPR 16.2.3:2012/Amdt 1:2015 Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity - Radiated disturbance measurements
  • AS/NZS CISPR 16.2.3:2012

GM Daewoo, Out-of-roundness measurement method

  • GMKOREA EDS-T-7714-2011 The Measuring Method of Kinematic Viscosity (Version 4; English/Korean; Do Not Use on New Program; No Replacement.)
  • GMKOREA EDS-T-7786-2012 Measurement Method to Density of Adhesives ???? ?? ?? ?? Version 5; English/Korean; This standard may be applied only for current projects. It is Superceded for all future projects and replaced by ASTM D1475 [Replaced: GMKOREA EDS-T-7786]

IX-CISPR, Out-of-roundness measurement method

  • CISPR 16-4-2:2011/AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-2:2011/AMD1:2014/AMD2:2018 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty

International Electrotechnical Commission (IEC), Out-of-roundness measurement method

  • CISPR 16-4-2:2011 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-2:2011+AMD1:2014+AMD2:2018 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-2-2011+AMD1-2014+AMD2-2018 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-2-2011+AMD1-2014 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
  • CISPR 16-4-1/TR-2005 Specification for radio disturbance and immunity measuring apparatus and methods--Part4-1:Uncertainties,statistics and limit modelling -Uncertainties in standardized EMC tests
  • CISPR 16-2-3 Edition 3.1-2010 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
  • CISPR 16-2-1 Edition 3.1-2017 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
  • CISPR 16-2-1-2010 Specification for radio disturbance and immunity measuring apparatus and methods – Part 2-1: Methods of measurement of disturbances and immunity – Conducted disturbance measurements
  • CISPR 16-2-1 Edition 2.2-2013 Specification for radio disturbance and immunity measuring apparatus and methods-Part 2-1: Methods of measurement of disturbances and immunity – Conducted disturbance measurements
  • CISPR 16-2-4:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-4: Methods of measurement of disturbances and immunity - Immunity measurements

中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会, Out-of-roundness measurement method

  • GB/T 6113.402-2018 Specification for radio disturbance and immunity measuring apparatus and methods—Part 4-2:Uncertainties, statistics and limit modelling—Measurement instrumentation uncertainty

Professional Standard - China Metal Association, Out-of-roundness measurement method

  • CSM 01 01 01 02-2006 Specification for Uncertainty Evaluation of Measurement Results by Spectrophotometry
  • CSM 01010102-2006 Specification for Uncertainty Evaluation of Measurement Results by Spectrophotometry
  • CSM 01 01 01 07-2006 Specification for Uncertainty Evaluation of Measurement Result of Determination of Carbon Quantity by Gas Volumetric Method
  • CSM 01010107-2006 Specification for Uncertainty Evaluation of Measurement Result of Determination of Carbon Quantity by Gas Volumetric Method
  • CSM 01 01 01 01-2006 Specification for Uncertainty Evaluation of Titration Measurement Results
  • CSM 01 01 01 01-2006 Specification for Uncertainty Evaluation of Titration Measurement Results
  • CSM 01010101-2006 Specification for Uncertainty Evaluation of Titration Measurement Results
  • CSM 01 01 01 06-2006 Specification for Uncertainty Evaluation of Measurement Results of Gas Analysis Methods in Iron, Steel and Alloys
  • CSM 01 01 02 02-2006 Uncertainty Evaluation of Metal Tensile Young's Modulus (Static Method) Measurement Results
  • CSM 01 01 02 02-2006 Evaluation of Uncertainty of Measurement Results of Young's Modulus in Tensile Metal (Static Method)
  • CSM 01010202-2006 Uncertainty Evaluation of Metal Tensile Young's Modulus (Static Method) Measurement Results
  • CSM 01 01 01 03-2006 Specification for Uncertainty Evaluation of Measurement Results of Atomic Absorption Spectrometry
  • CSM 01010103-2006 Specification for Uncertainty Evaluation of Measurement Results of Atomic Absorption Spectrometry

AASHTO - American Association of State Highway and Transportation Officials, Out-of-roundness measurement method

  • T 226-1990 Standard Method of Test for Triaxial Compressive Strength of Undrained Rock Core Specimens without Pore Pressure Measurements
  • T204-1990 Standard Method of Test for Density of Soil in-Place by the Drive Cylinder Method

国家卫生计生委, Out-of-roundness measurement method

  • WS/T 493-2017 Guidelines for Evaluating Measurement Uncertainty of Reference Methods in Enzymology Reference Laboratories

UY-UNIT, Out-of-roundness measurement method

Taiwan Provincial Standard of the People's Republic of China, Out-of-roundness measurement method

ZA-SANS, Out-of-roundness measurement method

  • SANS 216-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
  • SANS 5725-5:2009 Accuracy (trueness and precision) of measurement methods and results Part 5: Alternative methods for the determination of the precision of a standard measurement method

Military Standard of the People's Republic of China-General Armament Department, Out-of-roundness measurement method

  • GJB 772.103-1989 Test methods for explosives Particle size determination Disk centrifugal sedimentation method
  • GJB 1485-1992 Precision, accuracy and uncertainty of material physical property testing methods
  • GJB 8083-2013 The measurement method of atmospheric coherence length

NZ-SNZ, Out-of-roundness measurement method

  • NZS 4402.6.2.1:1986 Methods of Testing Soils for Civil Engineering Purposes Part 6.2: Soil Strength Tests - Determination of the Compressive Strength of Specimens Tested in Undrained Triaxial Compression Test 6.2.1: Method without Measurement of Pore Water Pressure
  • AS/NZS CISPR 16.4.2:2012 Specification for radio disturbance and immunity measuring apparatus and methods Part 4.2: Uncertainties, statistics and limit modelling-Measurement instrumentation uncertainty (Incorporating Amendment No.1: 05/2015)

Professional Standard - Ferrous Metallurgy, Out-of-roundness measurement method

  • YB/T 5350-2006 Method for Measuring High Temperature Elastic Modulus of Metallic Materials by Disc Oscillator Method
  • YB/T 4227-2010 Determination method of metal content in stainless steel slag

ES-UNE, Out-of-roundness measurement method

  • UNE-EN 951:1999 Door leaves - Method for measurement of height, width, thickness and squareness
  • UNE-EN 951:2000 ERRATUM DOOR LEAVES - METHOD FOR MEASUREMENT OF HEIGHT, WIDTH, THICKNESS AND SQUARENESS.
  • UNE-EN 55016-4-2:2012/A2:2019 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty

Professional Standard - Non-ferrous Metal, Out-of-roundness measurement method

  • YS/T 535.8-2006 Sodium fluoride chemical analysis method gravimetric determination of water insoluble matter

Professional Standard - Aviation, Out-of-roundness measurement method

  • HB 5219.7-1998 Magnesium Alloy Chemical Analysis Method Potassium Periodate Photometric Determination of Manganese Content (Excluding Zirconium and Rare Earth)

The American Road & Transportation Builders Association, Out-of-roundness measurement method

  • AASHTO T 226-1990 Standard Method of Test for Triaxial Compressive Strength of Undrained Rock Core Specimens without Pore Pressure Measurements

American National Standards Institute (ANSI), Out-of-roundness measurement method

RO-ASRO, Out-of-roundness measurement method

VN-TCVN, Out-of-roundness measurement method

  • TCVN 7269-2003 White sugar.Method of the determination of turbidity
  • TCVN 6910-3-2001 Accuracy (Trueness and precision) of measurement methods and results.Part 3: Intermediate measures of the precision of a standard measurement method
  • TCVN 4499-1988 Air in the zone of operration.Method of measuring unhealthy matters concentration using indicator tubes
  • TCVN 6910-4-2001 Accuracy (trueness and precision) of measurement methods and results.Part 4: Basic methods for the determination of the trueness of a standard measurement method
  • TCVN 6654-2000 Soil quality.Determination of water content in the unsaturated zone.Neutron depth probe method
  • TCVN 6053-2011 Water quality.Measurement of gross alpha activity in non-saline water.Thick source method
  • TCVN 6219-2011 Water quality.Measurement of gross beta activity in non-saline water.Thick source method
  • TCVN 5364-1991 Textiles.Method for determination of unevenness by the USTER equipment
  • TCVN 6910-5-2002 Accuracy (trueness and precision) of measurement methods and results.Part 5: Alternative methods for the determination of the precision of a standard measurement method
  • TCVN 6910-2-2001 Accuracy (trueness and precision) of measurement methods and results.Part 2: Basic methos for the determination of repeatability and reproducibility of a standard measurement method

Indonesia Standards, Out-of-roundness measurement method

American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), Out-of-roundness measurement method

Society of Automotive Engineers (SAE), Out-of-roundness measurement method

Professional Standard-Ships, Out-of-roundness measurement method

CN-STDBOOK, Out-of-roundness measurement method

  • 图书 A-4192 Evaluation of Uncertainty of Measurement by Monte Carlo Method Based on EXCELVBA

Professional Standard - Ocean, Out-of-roundness measurement method

FI-SFS, Out-of-roundness measurement method

Professional Standard - Light Industry, Out-of-roundness measurement method

  • QB/T 1936-1993 Quality assessment method for carbide-tipped circular saw blade for woodworking

IN-BIS, Out-of-roundness measurement method

HU-MSZT, Out-of-roundness measurement method

Professional Standard - Automobile, Out-of-roundness measurement method

  • QC/T 242-2004 Unbalance requirements and test methods of vehicle wheels
  • QC/T 242-1997 Automobile wheel unbalance requirements and test methods
  • QC/T 242-2014 Static unbalance requirements and test methods of vehicle wheels

IT-UNI, Out-of-roundness measurement method

  • UNI ISO 5725-4:2020 Accuracy (trueness and precision) of measurement methods and results - Part 4: Basic methods for the determination of the trueness of a standard measurement method

ETSI - European Telecommunications Standards Institute, Out-of-roundness measurement method

  • TR 102 273-1-2-2001 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Improvement on Radiated Methods of Measurement (Using Test Site) and Evaluation of the Corresponding Measurement Uncertainties; Part 1: Uncertainties in the Measurement of Mobile Radio Equipm
  • ETR 273-1-1-1998 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Improvement of Radiated Methods of Measurement (Using Test Sites) and Evaluation of the Corresponding Measurement Uncertainties; Part 1: Uncertainties in the Measurement of Mobile Radio Equip
  • ETR 273-1-2-1998 Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Improvement of Radiated Methods of Measurement (Using Test Sites) and Evaluation of the Corresponding Measurement Uncertainties; Part 1: Uncertainties in the Measurement of Mobile Radio Equip

VE-FONDONORMA, Out-of-roundness measurement method

TR-TSE, Out-of-roundness measurement method

  • TS 2245-1976 IRON ORES METHODS FOR MEAS?RING THE DENSITY
  • TS 2435-1976 Methods For The Measurement of Air Pollution Detera?ination of Lead (Colorimetric Method)

Shandong Provincial Standard of the People's Republic of China, Out-of-roundness measurement method

PT-IPQ, Out-of-roundness measurement method

  • NP EN 951-2000 Door leaves Methods for measurement of height,width,thickness and squareness

ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc., Out-of-roundness measurement method

  • ASHRAE SF-98-26-1-1998 Method for Measuring Fan Ventilation Rates in Livestock Buildings - Velocity Pressure Measurement

CH-SNV, Out-of-roundness measurement method

Professional Standard - Railway, Out-of-roundness measurement method

  • TB/T 2907-1998 Measurement method of circular runout of cylinder liner for locomotive diesel engine
  • TB/T 2798-1997 Measurement and Prediction Calculation Method of Three-phase Voltage Unbalance Caused by AC Electrified Railway

European Committee for Electrotechnical Standardization(CENELEC), Out-of-roundness measurement method

  • EN 55016-4-2:2011 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty (Incorporates Amendment A1: 2014)

CENELEC - European Committee for Electrotechnical Standardization, Out-of-roundness measurement method

  • EN 55016-4-2:2004 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-2: Uncertainties@ statistics and limit modelling Uncertainty in EMC measurements

Canadian General Standards Board (CGSB), Out-of-roundness measurement method

International Commission on Illumination (CIE), Out-of-roundness measurement method

  • CIE 198-SP1.1-2011 DETERMINATION OF MEASUREMENT UNCERTAINTIES IN PHOTOMETRY SUPPLEMENT 1: MODULES AND EXAMPLES FOR THE DETERMINATION OF MEASUREMENT UNCERTAINTIES Part 1: Modules for the Construction of Measurement Equations

DE-VDA, Out-of-roundness measurement method

CU-NC, Out-of-roundness measurement method

  • NC 40-12-1967 Method for determining textiles Products fastness Ironing fastness




Copyright ©2007-2023 ANTPEDIA, All Rights Reserved