17.220 电学、磁学、电和磁的测量 标准查询与下载



共找到 418 条与 电学、磁学、电和磁的测量 相关的标准,共 28

The scope of IEC 61326-1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as they can be found in industrial applications with an electromagnetic environment having specified characteristics (for example, process industry). The difference between the electromagnetic environment covered by this standard compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment.

ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE – EMC REQUIREMENTS – Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – Industrial appli...

ICS
17.220
CCS
发布
2012-08-09
实施

This part of GSO IEC 61557 specifies the requirements for measuring equipment applied to testing the phase sequence in three-phase distribution systems. Indication of the phase sequence may be mechanical, visual and/or audible. This part of GSO IEC 61557 does not apply to ancillary measuring equipment for other quantities, for example voltage testers comprising an additional phase sequence indicator. It does not apply to monitoring relays. NOTE Phase lamps are not considered to be voltage testers.

ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V a.c. AND 1500 V d.c. – EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES – Part 7: Phase sequence

ICS
17.220
CCS
发布
2012-08-09
实施

This part of GSO IEC 61557 specifies the general requirements for measuring and monitoring equipment for testing the electrical safety in low voltage distribution systems with nominal voltages up to 1 000 V a.c. and 1 500 V d.c. When measuring equipment or measuring installations involve measurement tasks of various measuring equipment covered by this series of standards, then the part of this series of standards relevant to each of the measurement tasks is applicable. NOTE The term "measuring equipment" will hereafter be used to designate "testing, measuring and monitoring equipment".

ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V a.c. AND 1500 V d.c. – EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES – Part 1: General requirements

ICS
17.220
CCS
发布
2012-08-09
实施

This part of GSO IEC 61557 specifies the requirements for insulation fault location systems which localize insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1 000 V a.c., as well as in unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle.

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems

ICS
17.220
CCS
发布
2012-08-09
实施

This part of GSO IEC 61557 specifies the requirements for equipment for measuring earth resistance using an a.c. voltage.

ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V a.c. AND 1 500 V d.c. – EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES – Part 5: Resistance to earth

ICS
17.220
CCS
发布
2012-08-09
实施

本规范规定了微波功率计的通用要求、测试方法、检验规则和标志、包装、运输、贮存等。本规范适用于终端二极管式微波功率计,其它类型的微波功率计也可参照本规范。

General specification for power meter

ICS
17.220
CCS
L86
发布
2012-05-24
实施
2012-06-01

本规范规定了矢量网络分析仪的通用要求、测试方法、检验规则和标志、包装、运输、贮存等。本规范适用于以合成信号发生器、接收机、S参数测试单元组成的典型两测试端口矢量网络分析仪,其它类型的矢量网络分析仪也可参照本规范。

General specification for vector network analyzer

ICS
17.220
CCS
L86
发布
2012-05-24
实施
2012-06-01

Determination of detection point of lightning protection device

ICS
17.220
CCS
L85
发布
2012-05-11
实施
2012-07-11

0.1S class static AC active energy meter

ICS
17.220
CCS
N20
发布
2012-05-11
实施
2012-07-11

IEC 62059-32-1:2011 specifies a method for testing the stability of metrological characteristics of electricity meters, by operating a test specimen at the upper limit of the specified operating range of temperature, voltage and current for an extended period.

Electricity metering equipment - Dependability - Part 32-1: Durability - Testing of the stability of metrological characteristics by applying elevated temperature

ICS
17.220
CCS
发布
2012-03-23
实施
2012-04-11 (7)

N/A

Electrical safety in low voltage distribution systems up to 1 000 v a.c. And 1 500 v d.c. – Equipment for testing, measuring or monitoring of protective measures – Part 3: loop impedance

ICS
17.220
CCS
发布
2011-10-12
实施

N/A

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems

ICS
17.220
CCS
发布
2011-10-12
实施

N/A

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 4: Resistance of earth connection and equipotential bonding

ICS
17.220
CCS
发布
2011-10-12
实施

N/A

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures – Part 2 : Insulation Resistance

ICS
17.220
CCS
发布
2011-10-12
实施

Cavity resonator method to measure the complex permittivity of low-loss dielectric plates (IEC 62562:2010)

ICS
17.220
CCS
发布
2011-05-16
实施
2011-05-16

Superconductivity -- Part 8: AC loss measurements - Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method (IEC 61788-8:2010)

ICS
17.220
CCS
发布
2011-02-15
实施
2011-02-15

IEC 61788-8:2010(E) specifies the measurement method of total AC losses by the pickup coil method in composite superconducting wires exposed to a transverse alternating magnetic field. The losses may contain hysteresis, coupling and eddy current losses. The standard method to measure only the hysteresis loss in DC or low-sweep-rate magnetic field is specified in IEC 61788-13. In metallic and oxide round superconducting wires expected to be mainly used for pulsed coil and AC coil applications, AC loss is generated by the application of time-varying magnetic field and/or current. The contribution of the magnetic field to the AC loss is predominant in usual electromagnetic configurations of the coil applications. For the superconducting wires exposed to a transverse alternating magnetic field, the present method can be generally used in measurements of the total AC loss in a wide range of frequency up to the commercial level, 50/60 Hz, at liquid helium temperature. For the superconducting wires with fine filaments, the AC loss measured with the present method can be divided into the hysteresis loss in the individual filaments, the coupling loss among the filaments and the eddy current loss in the normal conducting parts. In cases where the wires do not have a thick outer normal conducting sheath, the main components are the hysteresis loss and the coupling loss by estimating the former part as an extrapolated level of the AC loss per cycle to zero frequency in the region of lower frequency, where the coupling loss per cycle is proportional to the frequency. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision. The main changes with respect to the previous edition are listed below: - extending the applications of the pickup coil method to the a.c. loss measurements in metallic and oxide superconducting wires with a round cross section at liquid helium temperature, - using the word 'uncertainty' for all quantitative (associated with a number) statistical expressions and eliminating the quantitative use of 'precision' and 'accuracy'.

Superconductivity - Part 8: AC loss measurements - Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method

ICS
17.220
CCS
发布
2010-11-26
实施
2011-01-01 (7)

本部分在DL/T 698.31电能信息采集终端通用要求的基础上,规定了低压集中抄表终端(包括低压集中器、低压采集器)的特殊要求及其相应的试验方法。 本部分适用于低压集中抄表终端的制造、检验和使用。

Data acquisition and management system for electrical energy part3-5:technical specification of electrical energy data acquisition terminal-special requirement for meter rending terminal of LV customers

ICS
17.220
CCS
N22
发布
2010-05-24
实施
2010-10-01

本部分在DL/T 698.31电能信息采集终端通用技术要求基础上,规定了公变采集终端的特殊要求、试验方法和检验规则。 本部分适用于公变采集终端的制造、检验、使用和验收。

Data acquisition and management system for electrical energy part 3-4: technical specification of electrical energy data acquisition terminal- special requirement for data acquisition terminal of common transformer

ICS
17.220
CCS
N22
发布
2010-05-24
实施
2010-10-01

本部分规定了电能信息采集与管理系统主站的架构、基本要求、功能和性能要求。 本部分适用于电能信息采集与管理系统的设计、使用和验收。

Data acquisition and management system for electrical energy part 2: technical specification of master station

ICS
17.220
CCS
N22
发布
2010-05-24
实施
2010-10-01



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved