K31 低压配电电器 标准查询与下载



共找到 2417 条与 低压配电电器 相关的标准,共 162

Switches for appliances - Part 2-6: Particular requirements for switches used in electric motor-operated hand-held tools, transportable tools and lawn and garden machinery (IEC 61058-2-6:2016); German version EN 61058-2-6:2016

ICS
29.120.40
CCS
K31
发布
2017-04
实施

Switches for appliances - Part 1-2: Requirements for electronic switches (IEC 61058-1-2:2016); German version EN 61058-1-2:2016

ICS
29.120.40
CCS
K31
发布
2017-04
实施

Thermal-links - Requirements and application guide (IEC 60691:2015 + COR1:2016); German version EN 60691:2016

ICS
29.120.50
CCS
K31
发布
2017-04
实施

Miniature fuses. Guidelines for quality assessment of miniature fuse-links

ICS
29.120.50
CCS
K31
发布
2017-03-31
实施
2017-03-31

Components for low-voltage surge protective devices. Performance requirements and test methods for telecommunications and signalling network surge isolation transformers (SIT)

ICS
33.040.99
CCS
K31
发布
2017-02-28
实施
2017-02-28

Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units (IEC 60947-3:2008 + A1:2012 + A2:2015); German version EN 60947-3:2009 + A1:2012 + A2:2015

ICS
29.130.20
CCS
K31
发布
2017-02
实施

Switches for appliances - Part 1-1: Requirements for mechanical switches (IEC 61058-1-1:2016); German version EN 61058-1-1:2016

ICS
29.120.40
CCS
K31
发布
2017-02
实施

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules (IEC 61008-1:2010, modified + A1:2012, modified + A2:2013, modified + A2:2013/Cor.:2014); German version EN 6

ICS
29.120.50
CCS
K31
发布
2017-02
实施

This part of IEC 60669 applies to manually operated general purpose functional switches@ for alternating current (AC) only with a rated voltage not exceeding 440 V with a rated current not exceeding 63 A@ intended for household and similar fixed electrical installations@ either indoors or outdoors. For switches provided with screwless terminals@ the rated current is limited to 16 A. NOTE 1 The rated current is limited to 16 A for switches provided with insulation piercing terminals (IPT??s) according to Annex D. Switches covered by this document are@ where applicable@ intended for the control in normal use of all of the following loads: ?C a circuit for a tungsten filament lamp load; ?C a circuit for an externally ballasted lamp load (for example LED@ CFL@ fluorescent lamp load); ?C a circuit for a self ballasted lamp load (for example LEDi or CFLi); ?C a circuit for a substantially resistive load with a power factor not less than 0@95; ?C a single phase circuit for motor load with a rated current not exceeding 3 A at 250 V (750 VA) and 4@5 A at 120 V (540 VA) and a power factor not less than 0@6. This applies to both switches rated not less than 10 A that have not undergone additional tests and to momentary switches rated not less than 6 A that have not undergone additional tests. NOTE 2 In the following country the suitability of a switch intended to control the inrush current of a motor shall be tested: AU. This document also applies to boxes for switches@ with the exception of mounting boxes for flush-type switches. NOTE 3 General requirements for boxes for flush-type switches are given in IEC 60670-1. It also applies to switches such as ?C switches incorporating pilot lights; ?C electromagnetic remote control switches (particular requirements are given in IEC 606692- 2); ?C switches incorporating a time-delay device (particular requirements are given in IEC 60669-2-3); ?C combinations of switches and other functions (with the exception of switches combined with fuses); ?C electronic switches (particular requirements are given in IEC 60669-2-1); ?C switches having facilities for the outlet and retention of flexible cables (see Annex A); ?C isolating switches (particular requirements are given in IEC 60669-2-4); ?C switches and related accessories for use in home and building electronic systems (particular requirements are given in IEC 60669-2-5); ?C firemen??s switches (particular requirements are given in IEC 60669-2-6). Switches complying with this document are suitable for use at ambient temperatures not normally exceeding +40 ?? but their average over a period of 24 h does not exceed +35 ?? with a lower limit of the ambient air temperature of ?C5 ?? NOTE 4 For lower temperatures see Annex E. Switches complying with this document are suitable only for incorporation in equipment in such a way and in such a place that it is unlikely that the surrounding ambient temperature exceeds +35 ?? In locations where special conditions prevail@ such as in ships@ vehicles and the like and in hazardous locations@ for example where explosions are liable to occur@ special construction and/or additional requirements may be required

Switches for household and similar fixed electrical installations - Part 1: General requirements

ICS
29.120.40
CCS
K31
发布
2017-02
实施
2017-02-24

UL Standard for Safety Low-Voltage Switchgear and Controlgear - Part 7-2: Ancillary Equipment - Protective Conductor Terminal Blocks for Copper Conductors (Fourth Edition)

ICS
CCS
K31
发布
2017-01-27
实施

UL Standard for Safety Low-Voltage Switchgear and Controlgear - Part 7-3: Ancillary Equipment - Safety Requirements for Fuse Terminal Blocks (Third Edition)

ICS
CCS
K31
发布
2017-01-27
实施

UL Standard for Safety Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (Fourth Edition)

ICS
CCS
K31
发布
2017-01-27
实施

The IEC 62873 series covers available common standards intended to be used in conjunction with or for the preparation of RCD (residual current device) standards. This part of IEC 62873 defines the methodology and processes used when producing standards based on a new approach (hereafter referred to as blocks and modules) aiming at harmonizing a family of standards, thus avoiding mistakes, inconsistencies or discrepancies within this family of standards. The family of standards considered in this document consists of standards for RCCBs (Residual Current Circuit-Breakers without overcurrent protection), RCBOs (Residual Current Circuit-Breakers with overcurrent Protection), and general safety requirements for residual current operated protective devices (namely IEC 61008-1, IEC 61009-1 and IEC TR 60755). This approach defines a way to optimize drafting of standards, aiming to keep a common or similar structure, to have common clauses (as far as possible), to avoid inconsistencies, to do editorial work only once, to speed up production of standards, to ensure that a comment on one clause in one standard is also taken into account in other standards, if needed. The principles of the blocks and modules approach are: to identify those parts of the standards which need to be identical (or with limited differences), and those parts of the standards which should remain different; to set a library of those common parts; to identify the parts which should be published as stand-alone standards; to draft product standards, using the library; to keep track of the common parts used in a product standard when revision will be needed in the future. This document also lists the available blocks and modules which were prepared for RCD product standards.

Residual current operated circuit-breakers for household and similar use - Part 1: Outline of blocks and modules for residual current device standards

ICS
29.120.30;29.120.50
CCS
K31
发布
2017-01
实施
2017-01-28

Low-voltage switchgear and controlgear - Part 1: General rules (IEC 60947-1:2007 + A1:2010 + A2:2014); German version EN 60947-1:2007 + A1:2011 + A2:2014, Corrigendum to DIN EN 60947-1 (VDE 0660-100):2015-09

ICS
29.130.20
CCS
K31
发布
2017-01
实施

Safety devices for protection against excessive pressure - Part 1: Safety valves (ISO 4126-1:2013 + Amd 1:2016); German version EN ISO 4126-1:2013 + A1:2016

ICS
13.240
CCS
K31
发布
2016-12
实施

Safety devices for protection against excessive pressure - Part 7: Common data (ISO 4126-7:2013 + Amd 1:2016); German version EN ISO 4126-7:2013 + A1:2016

ICS
13.240
CCS
K31
发布
2016-12
实施

Switches for household and similar fixed electrical installations. Particular requirements. Switches and related accessories for use in home and building electronic systems (HBES)

ICS
29.120.40;97.120
CCS
K31
发布
2016-11-30
实施
2016-11-30

Switches for appliances. Particular requirements for switches used in electric motor-operated hand-held tools, transportable tools and lawn and garden machinery

ICS
29.120.40
CCS
K31
发布
2016-11-30
实施
2016-11-30

Thermal-links. Requirements and application guide

ICS
29.120.50
CCS
K31
发布
2016-11-30
实施
2016-11-30

Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules (IEC 61008-1:2010, modified + A1:2012, modified + A2:2013, modified + A2:2013/Cor.:2014); German version EN 6

ICS
29.120.50
CCS
K31
发布
2016-10
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号