K43 高压开关设备 标准查询与下载



共找到 829 条与 高压开关设备 相关的标准,共 56

This part of IEC 62271 applies to a.c. switchgear and controlgear designed for indoor and outdoor installation and for operation at service frequencies up to and including 60Hz on systems having voltages above 1 000 V. This standard applies to all high-voltage switchgear and controlgear except as otherwise specified in the relevant IEC standards for the particular type of switchgear and controlgear. NOTE For the use of this standard, high voltage (see IEV 601-01-27) is the rated voltage above 1 000 V. However, the term medium voltage (see IEV 601-01-28) is commonly used for distribution systems with voltages above 1 kV and generally applied up to and including 52 kV.

High-voltage switchgear and controlgear.Part 1: Common specifications

ICS
29.130.10;29.130.99
CCS
K43
发布
2011-08
实施

This part of IEC 62271 applies to alternating current disconnectors and earthing switches@ designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz.It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment.Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in IEC 60298@ IEC 60466 and IEC 60517.NOTE Disconnectors in which the fuse forms an integral part are not covered by this standard.

High-voltage switchgear and controlgear - Part 102: Alternating current disconnectors and earthing switches; Amendment 1

ICS
29.130.10;29.130.99
CCS
K43
发布
2011-08
实施
2012-04-29

"Scope and object This part of IEC 62271 is applicable to a.c. contactors and/or contactor-based controllers and motor-starters designed for indoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V but not exceeding 24 000 V. It is applicable only to three-pole devices for use in three-phase systems@ and single-pole devices for use in single-phase systems. Two-pole contactors and starters for use in singlephase systems are subject to agreement between manufacturer and user. Contactors and/or starters dealt with in this standard typically do not have adequate short-circuit interruption capability. In this context@ this standard gives requirements for ?C motor starters associated with separate short-circuit protective devices; ?C controllers - contactors combined with short-circuit protective devices (SCPD). Contactors intended for closing and opening electric circuits and@ if combined with suitable relays@ for protecting these circuits against operating overloads are covered in this standard. This standard is also applicable to the operating devices of contactors and to their auxiliary equipment. Motor-starters intended to start and accelerate motors to normal speed@ to ensure continuous operation of motors@ to switch off the supply from the motor and to provide means for the protection of motors and associated circuits against operating overloads are dealt with. Motor-starter types included are ?C direct-on-line starters; ?C reversing starters; ?C two-direction starters; ?C reduced kVA (voltage) starters; ?auto-transformer starters; ?rheostatic starters; ?reactor starters. This standard does not apply to ?C circuit-breaker-based motor-starters; ?C single-pole operation of multi-pole contactors or starters; ?C two-step auto-transformer starters designed for continuous operation in the starting position; ?C unbalanced rheostatic rotor starters@ i.e. where the resistances do not have the same value in all phases; ?C equipment designed not only for starting@ but also for adjustment of speed; ?C liquid starters and those of the ""liquid-vapour"" type; ?C semiconductor contactors and starters making use of semiconductor contactors in the main circuit; ?C rheostatic stator starters; ?C contactors or starters designed for special applications. This standard does not deal with components contained in contactors and contactor-based motor-starters@ for which individual specifications exist. NOTE 1 Thermal electrical relays are covered by IEC 60255-8. NOTE 2 High-voltage current-limiting fuses are covered by IEC 60282-1 and IEC 60644. NOTE 3 Metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV are covered by IEC 62271-200. NOTE 4 Disconnectors and earthing switches are covered by IEC 62271-102. NOTE 5 High-voltage switches above 1 kV and less than 52 kV are covered by IEC 62271-1031. The object of this standard is to state a) the characteristics of contactors and starters and associated equipment; b) the conditions with which contactors or starters shall comply with reference to: 1) their operation and behaviour@ 2) their dielectric properties@ 3) the degrees of protection provided by their enclosures@ where applicable@ 4) their construction@ 5) for controllers@ interactions between the various components@ for example SCPD co-ordination; c) the tests intended for confirming that these conditions have been met@ and the methods to be adopted for these tests; d) the information to be given with the equipment or in the manufacturer's literature."

High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters

ICS
29.130.10
CCS
K43
发布
2011-08
实施
2011-08-23

This part of IEC 62271 is applicable to voltage presence indicating systems (VPIS) incorporated in a.c. switchgear and controlgear covered by IEC 62271-200 or IEC 62271-201. Voltage presence indicating systems are devices used to provide information to operators about the voltage condition of the main circuit of the switchgear in which they are installed. The indication of VPIS alone is not sufficient to prove that the system is dead: if operating procedures make it mandatory, relevant voltage detectors according to IEC 61243-1, IEC 61243-2 and IEC 61243-5 should be used. This standard is also applicable to phase comparators specifically designed for use with VPIS.

High-voltage switchgear and controlgear. Voltage presence indicating systems for rated voltages above 1 kV and up to and including 52 kVkV and up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2011-07-31
实施
2011-07-31

"This part of IEC 62271 applies to rigid HV gas-insulated transmission lines (GIL) in which the insulation is obtained@ at least partly@ by a non-corrosive insulating gas@ other than air at atmospheric pressure@ for alternating current of rated voltages above 52 kV@ and for service frequencies up to and including 60 Hz. It is intended that this international standard be used where the provisions of IEC 62271-203 do not cover the application of GIL (see NOTE 3). At each end of the HV gas-insulated transmission line@ a specific element may be used for the connection between the HV gas-insulated transmission line and other equipment like bushings@ power transformers or reactors@ cable boxes@ metal-enclosed surge arresters@ voltage transformers or GIS@ covered by their own specification. Unless otherwise specified@ the HV gas-insulated transmission line is designed to be used under normal service conditions. NOTE 1 In this international standard@ the term ""HV gas-insulated transmission line"" is abbreviated to ""GIL"". NOTE 2 In this international standard@ the word ""gas"" means gas or gas mixture@ as defined by the manufacturer. NOTE 3 Examples of GIL applications are given: ?C where all or part of the HV gas-insulated transmission line is directly buried; or ?C where the HV gas-insulated transmission line is located@ wholly or partly@ in an area accessible to public; or ?C where the HV gas-insulated transmission line is long and the typical gas compartment length exceeds the common practice of GIS technology."

High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV

ICS
29.130.10
CCS
K43
发布
2011-07
实施
2011-07-28

This International Standard is applicable to high-voltage switchgear and controlgear (scope of IEC SC 17A) and assemblies thereof (scope of IEC SC 17C) and specifies equipment for digital communication with other parts of the substation and its impact on testing. This equipment for digital communication@ replacing metal parallel wiring@ can be integrated into the high-voltage switchgear@ controlgear@ and assemblies thereof@ or can be an external equipment in order to provide compliance for existing switchgear and controlgear and assemblies thereof with the standards of the IEC 61850 series.This International Standard is a product standard based on the IEC 61850 series. It deals with all relevant aspects of switchgear and controlgear@ and assemblies thereof with a serial communication interface according to the IEC 61850 series. In particular it defines:a) A selection of the information models from the IEC 61850 series that shall be supported by such switchgear and controlgear@ and assemblies thereof.b) Conformance classes for the set of communication services that shall be supported by the switchgear and controlgear@ and assemblies thereof.c) Modifications and extensions to type and routine tests of switchgear and controlgear@ and assemblies thereof that are required due to the serial communication interface.d) An extension of the IEC 61850 series?? object model for switchgear monitoring.NOTE 1 It is intended to integrate the extension of the IEC 61850 series?? object model for switchgear monitoring into a further revision of the IEC 61850 series. Once this integration is completed@ the relevant parts will be removed from this standard.The document is based on the IEC 61850 series@ the horizontal standard series for communication@ and specifies the requirements for digital communication equipment used within high-voltage switchgear@ controlgear@ and assemblies thereof@ as well as the relevant testing requirements.The relevant switchgear standards of the IEC 62271 series are applicable in general@ with the additional specifications described in this standard.NOTE 2 There is a limited activity today concerning switchgear with digital interface for rated voltage levels less than@ or equal to@ 52 kV. Such switchgear usually does not have integrated digital communication interfaces. If such products are to be developed@ this should be done in accordance with the present standard.NOTE 3 This standard intends to promote interoperability of communication interfaces. Interchangeability is outside the scope of this standard@ as there is no requirement for it. Interchangeability is also outside the scope of the IEC 61850 series.NOTE 4 For an introduction to substation communication and the related terms@ definitions and models@ refer to IEC 61850-1 which provides an overview of the objectives and requirements of the IEC 61850 series in general. IEC 61850-7-1 provides an overview of modelling techniques.

High-voltage switchgear and controlgear - Part 1: Common specifications

ICS
29.130.10
CCS
K43
发布
2011-06
实施
2011-08-12

High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2011-06
实施

High-voltage switchgear and controlgear - Part 101: Synthetic testing (IEC 62271-101:2006/A1:2010); German version EN 62271-101:2006/A1:2010

ICS
29.130.10
CCS
K43
发布
2011-05
实施
2011-05-01

本标准适用于电压3.0kV及以上,频率为50Hz的电力系统中运行的户内和户外、端子是封闭或敞开的交流隔离开关和接地开关,以及它们的操动机构及其辅助设备。封闭式开关设备和控制设备中的隔离开关和接地开关的附加要求在GB 3906-2006、GB 7674-2008和IEC 62271-201:2003中给出。

High-voltage alternating-current disconnectors and earthing switches

ICS
29.120.40
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了12kV户外高空真空断路器参数、检修周期、检修前的准备工作、检修工艺及质量标准、试验项目及要求。 本标准适用于额定电压12kV、额定频率50Hz的空气绝缘方式的户外高压真空断路器。

The maintenance code of 12kV outdoor highvoltage vacuum circuit-breaker

ICS
29.130.10
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了交流自动分段器的额定值、结构与设计、试验、选用、运输、储存、安装、运行和维护等要求。 本标准适用于额定电压12kV,频率50Hz的电力系统中运行的户外交流自动分段器。 本标准不适用于火灾、爆炸、化学腐蚀危险及剧烈振动场所使用的分段器。

Specification for automatic line sectionalizers for AC systems

ICS
29.120.40
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了微机型防止电气误操作系统的使用条件、额定值、设计和结构、试验及选用导则等内容。 本标准适用于电力系统高压电气设备及其附属装置用微机型防止电气误操作系统。

General specification for preventing electric mal-operation system with computer

ICS
29.240
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了户外配电箱的使用条件、功能单元配置、技术条件和试验要求。 本标准适用于交流频率50Hz,额定电压400V(绝缘电压小于等于660V)及以下的农村电网中,安装容量为315kVA及以下变压器端,具有计量、测量、控制、保护、电能分配、无功补偿等全部或部分功能单元为一体的户外配电箱。

General technical condition for outdoor distribution box

ICS
29.240.01
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了农村电网无人值班变电站运行管理的职能、管理内容与要求。 本标准适用于农网110kV及以下无人值班变电站的运行管理。

The operated management standard of unattend-substation for the rural electric power network

ICS
29.130.10
CCS
K43
发布
2011-01-09
实施
2011-05-01

本标准规定了交流特高压变电(开关)站1100kV气体绝缘金属封闭开关设备现场检修的工作要求。 本标准适用于1100kV GIS/HGIS设备的检修工作。

Guide for AC 1100kV GIS/HGIS maintenance

ICS
29.130.10
CCS
K43
发布
2011-01-09
实施
2011-05-01

Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers

ICS
29.120.40
CCS
K43
发布
2011-01-01
实施

High-voltage switchgear and controlgear - Part 104 : alternating current switches for rated voltages of 52 kV and above.

ICS
29.130.10
CCS
K43
发布
2011-01-01
实施
2011-01-01

High-voltage switchgear and controlgear - Part 101 : synthetic testing.

ICS
29.130.10
CCS
K43
发布
2011-01-01
实施
2011-01-01

Single-support earthing switch - Rated voltage 420 kV - Terminal and mounting dimensions, layout

ICS
29.120.40
CCS
K43
发布
2011-01
实施

This part of IEC 62271 is applicable to voltage presence indicating systems (VPIS) incorporated in a.c. switchgear and controlgear covered by IEC 62271-200 or IEC 62271-201. Voltage presence indicating systems are devices used to provide information to operators about the voltage condition of the main circuit of the switchgear in which they are installed. The indication of VPIS alone is not sufficient to prove that the system is dead: if operating procedures make it mandatory, relevant voltage detectors according to IEC 61243-1, IEC 61243-2 and IEC 61243-5 should be used. This standard is also applicable to phase comparators specifically designed for use with VPIS.

High-voltage switchgear and controlgear - Part 206: Voltage presence indicating system for rated voltages above 1 kV and up to and including 52 kV

ICS
29.130.10
CCS
K43
发布
2011-01
实施
2011-01