This drawing documents two product assurance class levels consisting of high reliability (device classes Q and M) and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of Radiation Hardness Assurance (RHA) levels are reflected in the PIN
MICROCIRCUIT, LINEAR, TIMER, MONOLITHIC SILICON
Polymeric thermistors - Directly heated positive step function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application (IEC 62319-1-1:2005); German version EN 62319-1-1:2005
Polymeric thermistors - Directly heated positive step function temperature coefficient - Part 1: Generic specification (IEC 62319-1:2005); German version EN 62319-1:2005
Provides consensus calibration methods for electromagnetic field sensors and field probes.
Standard for Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz
Recommended practices for gyroscope and accelerometer testing are discussed, ranging from the equipment and instrumentation employed to the way that tests are carried out and data are acquired and analyzed. Recommendations are made on techniques for acquisition, filtering, storage, and analysis of the test data in keeping with modern practice.
Recommended Practice for Inertial Sensor Test Equipment, Instrumentation, Data Acquisition, and Analysis
The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.mil.
PROBE, TOTAL TEMPERATURE, DEICEABLE
本规范规定了CY-YZ-007A101型、CY-YZ-007A161型、CY-YZ-007A251型、CY-YZ-007 A351型、CY-YZ-007A701、CY-YZ-007A122型、CY-YZ-007A17642型等系列高温绝压传感器的详细要求。 本规范适用于CY-YZ-007系列高温绝压传感器(以下简称传感器)。
Detail specification of high temperature absolute pressure sensor for series CY-YZ-007
本规范规定了CY-YZ-006D101型、CY-YZ-006D601型、CY-YZ-006D252型、CY-YZ-006D602型系列高温压差传感器的详细要求。 本规范适用于CY-YZ-006系列高温压差传感器(以下简称传感器)。
Detail specification of high temperature defferential pressure sensor for series CY-YZ-006
本规范规定了CY-YZ-008 A610型、CY-YZ-008 A152型、CY-YZ-008 A202型、CY-YZ-008 、CY-YZ-008A602型、CY-YZ-008A103型、CY-YZ-008A353型等系列常温绝压传感器的详细要求。 本规范适用于CY-YZ-008系列常温绝压传感器(以下简称传感器)。
Detail specification of normal temperature absolute pressure sensor for series CY-YZ-008
本规范规定了CY-YZ-005G101型、CY-YZ-005G601型、CY-YZ-005G252型、CY-YZ-005G602型、 CY-YZ-005G103型、CY-YZ-005G203型、CY-YZ-005G403型、CY-YZ-005G603型等系列高温表压传感器的详细要求。 本规范适用于CY-YZ-005系列高温表压传感器(以下简称传感器)。
Detail specification of high temperature gauge pressure sensor for series CY-YZ-005
Test equipment, data acquisition equipment, instrumentation, test facilities, and data analysis techniques used in inertial sensor testing are described.
IEEE Recommended Practice for Inertial Sensor Test Equipment, Instrumentation, Data Acquisition, and Analysis
Provides consensus calibration methods for electromagnetic field sensors and field probes.
Calibration of Electromagnetic Field Sensors and Probes, Excluding Antennas, from 9 kHz to 40 GHz
High frequency inductive components - Non-electrical characteristics and measuring methods - Part 2 : test methods for non-electrical characteristics.
本部分规定了采用测量随时间变化的参考加速度、速度或力的方法,对直线加速度计进行冲击比较 法校准的仪器设备及操作程序。本方法适用于冲击脉冲持续时间范围”为o.05ms~8.o llls,动态范围 (峰值)为100 m/s’一loo km/s’(与脉冲持续时间有关)。这些方法可以得到传感器的冲击灵敏度(也 就是加速度传感器输出量的峰值和加速度峰值的关系)。 这些方法不用叼;模态分析,卜川的动态力传感器的校准。 注l:本部分针对的是那些从事冲击测量的川户,他们需要如GB/T 19001《质量管理体系 要求》(idt ISO 9001)和 GB/T 1548“检测和校准实验室能力的通用要求》(idt ISO/IEC 17025)所述的可溯源性。 注2:本部分规定的方法基刁:加速度的时间历程的测量,从根本—上不同于GB/T 20485.1 2008所述基于:速度变化原 理的其他冲击校准方法,因此冲击灵敏度电从根本上不同于后者得到的冲击校准因子,但和GB/T 20485.13- 2007冲击灵敏度一致。
Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer
The activities above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http://assist.daps.dla.
TRANSMITTER, PRESSURE, MULTIPURPOSE, 0-50 PSI, MS28005-1
Thermistors - Directly heated positive step-function temperature coefficient - Part 1 : generic specification.
Is a supplementary document to the generic specification and contains requirements for style and layout and minimum content of detail specifications. Detail specifications not complying with these requirements shall not be considered as being in accordan
Polymeric thermistors - Directly heated positive step function temperature coefficient - Part 1-1: Blank detail specification - Current limiting application
Prescribes terms and methods of test for polymeric positive temperature coefficient thermistors, insulated and non-insulated types, typically intended for use in current limiting and overcurrent protection applications. It establishes standard terms, ins
Polymeric thermistors - Directly heated positive step function temperature coefficient - Part 1: Generic specification
This draft standard applies to bonding and grounding for the prevention of ESD in an EPA..
ESD Association Standard for the Protection of Electrostatic Discharge Susceptible Items - Grounding
1.1 This practice is used for routinely checking the sensitivity of acoustic emission (AE) sensors. It is intended to provide a reliable, precisely specified way of comparing a set of sensors, or telling whether an individual sensor''s sensitivity has degraded during its service life, or both.1.2 This practice is not a "calibration" nor does it give frequency response information.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are provided for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Standard Practice for Verifying the Consistency of AE-Sensor Response Using an Acrylic Rod