N12 流量与物位仪表 标准查询与下载



共找到 506 条与 流量与物位仪表 相关的标准,共 34

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,0 and class 1,5 battery powered ultrasonic gas meters (hereinafter referred to as meters), having co-axial single pipe, or two pipe connections, used to measure volumes of distributed fuel gases of the second and/or third family, as given in EN 437, at maximum working pressures not exceeding 0,5bar1) and maximum actual flow rates of up to 10 m3/h over a minimum ambient temperature range of -10 ~C to +40 ~C, and minimum gas temperature span of 40 K, for domestic applications. This European Standard applies to meters where the measuring element and the register(s) are enclosed in the same case. This European Standard applies to meters with and without built-in temperature conversion, that are installed in locations with vibration and shocks of Iow significance and in -- closed locations (indoor or outdoor with protection as specified by the manufacturer) with condensing or with non-condensing humidity or, if specified by the manufacturer, open locations (outdoor without any covering) with condensing humidity or with non-condensing humidity and in locations with electromagnetic disturbances. Unless otherwise stated, all pressures given in this European Standard are gauge pressures. When more than one meter type is submitted for testing, then each meter type is required to be tested against this European Standard. Clauses 1 to 15 and Annex C are for design and type testing only. NOTE See Annex A for production requirements.

Ultrasonic domestic gas meters; English version of DIN EN 14236:2008-06

ICS
91.140.40
CCS
N12
发布
2008-06
实施
2008-06-01

This International Standard specifies the functional requirements of the equipment, excluding bankside cableway systems, used in the measurement of liquid flow in open channels for a) sounding (by direct method), and b) suspending the measuring equipment (for example, current-meter or sediment sampler) at the point of measurement.

Hydrometry - Direct depth sounding and suspension equipment

ICS
17.120.20
CCS
N12
发布
2008-05-30
实施
2008-05-30

This International Standard defines the requirements for the use of rectangular and triangular (V-notch) thinplate weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow conditions.

Hydrometry - Open channel flow measurement using thin-plate weirs

ICS
17.120.20
CCS
N12
发布
2008-05-30
实施
2008-05-30

本规程适用于对测量气体流量的临界流文丘里喷嘴和出口无扩散段的临界流喷嘴的首次检定、后续检定和使用中检验。

Verification Regulation of Critical Flow Venturi Nozzle

ICS
17.120.01
CCS
N12
发布
2008-05-23
实施
2008-11-23

ISO/TR 9464:2008 provides guidance on the use of ISO 5167:2003 (all parts). ISO 5167:2003 is an International Standard for flow measurement based on the differential pressure generated by a constriction introduced into a circular conduit. It presents a set of rules and requirements based on theory and experimental work undertaken in the field of flow measurement.

Guidelines for the use of ISO 5167:2003

ICS
17.120.10
CCS
N12
发布
2008-05-15
实施

This International Standard defines the requirements for the use of rectangular and triangular (V-notch) thinplate weirs for the measurement of flow of clear water in open channels under free flow conditions. It includes the requirements for the use of full-width rectangular thin-plate weirs in submerged (drowned) flow conditions.

Hydrometry - Open channel flow measurement using thin-plate weirs

ICS
CCS
N12
发布
2008-04-15
实施

This International Standard specifies the functional requirements of the equipment, excluding bankside cableway systems, used in the measurement of liquid flow in open channels for a) sounding (by direct method), and b) suspending the measuring equipment (for example, current-meter or sediment sampler) at the point of measurement.

Hydrometry - Direct depth sounding and suspension equipment

ICS
17.120.20
CCS
N12
发布
2008-04-15
实施

This International Standard lays down requirements for the use of rectangular broad-crested weirs for the accurate measurement of flow of clear water in open channels under free flow conditions.

Hydrometry - Open channel flow measurement using rectangular broad-crested weirs

ICS
17.120.20
CCS
N12
发布
2008-03-31
实施
2008-03-31

本规程适用于涡轮流量计(以下简称流量计)的形式评价、首次检定和持续检定。

Verification Regulation of Turbine Flowmeter

ICS
CCS
N12
发布
2008-03-25
实施
2008-06-25

This part of ISO 18132 establishes the general requirements for the specification, installation and calibration/verification testing of automatic level gauges (ALG) used for refrigerated light hydrocarbon fluids, i.e., LNG and LPG, stored in bulk storage tanks on shore at pressures close to atmosphere. This part of ISO 18132 is not applicable to pressurized shore tanks.

Refrigerated light hydrocarbon fluids - General requirements for automatic level gauges - Part 2: Gauges in refrigerated-type shore tanks

ICS
75.180.30
CCS
N12
发布
2008-03-15
实施

この規格は,参照標準としてトレーサビリティが明確な流量計(標準流量計)を用いて,気体用流量計を校正及び試験する方法,並びに不確かさ及び偏差(器差)の計算方法について規定する。

Procedures of calibration and testing for gas flowmeter

ICS
17.120.10
CCS
N12
发布
2008-01-20
实施
2008-01-21

This standard applies where the entire flow stream of the volatile refrigerant enters and exits either as a “vapor only” or “liquid only” state. This standard covers all refrigerants listed in ANSI/ ASHRAE Standard 34-2004, Designation and Safety Classification of Refrigerants.

Standard Methods for Volatile-Refrigerant Mass Flow Measurements Using Flowmeters

ICS
CCS
N12
发布
2008-01-19
实施

Thermomechanical analyzers are employed in their various modes of operation (penetration, expansion, flexure, etc.) to characterize a wide range of materials. In most cases, the value to be assigned in thermomechanical measurements is the temperature of the transition (or event) under study. Therefore, the temperature axis (abscissa) of all TMA thermal curves must be accurately calibrated either by direct reading of a temperature sensor or by adjusting the programmer temperature to match the actual temperature over the temperature range of interest.1.1 This test method describes the temperature calibration of thermomechanical analyzers from − 50 to 1100 °C. (See Note 1.) 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard is similar to ISO 11359–1 but addresses a larger temperature range and utilizes additional calibration materials. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 7 and Note 9.

Standard Test Method for Temperature Calibration of Thermomechanical Analyzers

ICS
17.200.20 (Temperature-measuring instruments)
CCS
N12
发布
2008
实施

本检定系统表适用于充满封闭管道的液体流量计量器具的量值传递,它包括从主要基本量和导出量、液体流量计量基准器具、液体流量计量标准器具直至液体流量工作计量器具之间的量值传递关系、量值传递方法和量值传递时的最佳测量能力。

Measuring Instruments for Liquid Flow

ICS
CCS
N12
发布
2007-11-21
实施
2008-05-21

本规范适用于传感器为热电偶或热电阻的温度变送器(以下简称变送器)的校准。变送器包括带温度传感器和不带温度传感器的。

Calibration Specification of the Temperature Transmitter

ICS
CCS
N12
发布
2007-11-21
实施
2008-05-21

本堆积适用于冷水水表(以下简称水表)的型式评价、首次检定、后续检定和使用中检验。 本规程适用于测量流经封闭满管道清洁水的水表,包括机械式水表、配备了电子装置的机械式水表、基于电磁或电子原理工作的水表,也适用于水表的电子辅助装置。水表的工作温度主要在30℃以下。

Verification Regulation of Cold Water Meter

ICS
CCS
N12
发布
2007-11-21
实施
2008-05-21

Specification for multi-tube parallelism detector for artillery

ICS
CCS
N12
发布
2007-11-01
实施
2007-11-01

本规范规定了舰船用电磁流量计(以下简称流量计)的技术要求、质量保证规定、交货准备等。 本规范适用于流量计的研制、生产和验收。

Specincation for electromagnetic flowmeters of ships

ICS
CCS
N12
发布
2007-10-10
实施
2008-03-01

This Technical Report provides guidance on estimating the flowrate when using pressure differential devices constructed or operated outside the scope of ISO 5167. Additional tolerances or corrections cannot necessarily compensate for the effects of deviating from ISO 5167(all parts).The information is given,in the first place,to indicate the degree of care necessary in the manufacture,installation and maintenance of pressure differential devices by describing some of the effects of non-conformity to the requirements;and in the second place,to permit those users who cannot comply fully with the requirements to assess,however roughly,the magnitude and direction of the resulting error in flowrate. Each variation dealt with is treated as though it were the only one present.Where more than one is known to exist,there may be unpredictable interaction and care has to be taken when combining the assessment of these errors.If there is a significant number of errors,means of eliminating some of them have to be considered.The variations included in this Technical Report are by no means complete and relate largely to examples with orifice plates.An example with Venturi tubes has been placed at the end of its section.There are,no doubt,many similar examples of installations not conforming to ISO 5167(all parts)for which no comparable data have been published.Such additional information from users,manufacturers and any others may be taken into account in future revisions of this Technical Report.

Measurement of fluid flow by means of pressure differential devices - Guidelines on the effect of departure from the specifications and operating conditions given in ISO 5167

ICS
17.120.10
CCS
N12
发布
2007-09-01
实施

本规程适用于涡街流量计 (以下统称为流量计)的型式评价、首次检定、后续检定和使用中的检验。

Vortex-shedding Flowmeter

ICS
CCS
N12
发布
2007-08-21
实施
2007-11-21



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved