共找到 317 条与 声学仪器与测震仪 相关的标准,共 22 页
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for transverse shock sensitivity testing. It applies to rectilinear accelerometers of the strain gauge, piezoresistive and piezoelectric type. This part of ISO 5347 is applicable for a time range from 0,01 ms to 10 ms and a dynamic range from 100 m/s to 10 m/s. The limits of uncertainty applicable are ± 20 % of reading.
Calibration of vibration and shock pick-ups. Method of test for transverse shock sensitivity
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary high impact shock calibration of ac-celerometers. It applies to rectilinear accelerometers, mainly of the piezoelectric and piezoresistive type, to primary standards and working accelerometers. This part of ISO 5347 is applicable for a time range from 10 μs to 100 μs and a dynamic range from 10 m/s to 10 m/s. The limit of uncertainty applicable is ±10 % of read-ing.
Calibration of vibration and shock pick-ups. Method for primary calibration by high impact shocks
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for comparison phase angle vibration calibration. It applies to rectilinear and working pick-ups. The limits of uncertainty applicable are ±3 % of reading.
Calibration of vibration and shock pick-ups - Method for secondary vibration calibration by comparison of phase angles
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. It applies to all types of rectilinear accelerometers, primary standards and working pick-ups. This part of ISO 5347 is applicable for a frequency range from 0,7 Hz to 10 Hz and a dynamic range from 10 m/s to 100 m/s. The limits of uncertainty applicable are ± 2 % of reading.
Calibration of vibration and shock pick-ups. Method for primary calibration by dual centrifuge
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of accelerometers using centrifuge calibration. This part of ISO 5347 applies to rectilinear acceler-ometers with zero-frequency response, mainly of the strain gauge or piezoresistive type, and to primary standard and working pick-ups. It is applicable for a calibration range from 10 m/s to 1 000 m/s (higher accelerations possible) at 0 Hz. The limits of uncertainty applicable are ± 1 % of reading.
Calibration of vibration and shock pick-ups. Methods for primary calibration by centrifuge
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of accelerometers at low frequencies. It applies to all kinds of pick-ups. This part of ISO 5347 is applicable for a frequency range from 0,5 Hz to 20 Hz and a dynamic range from 1 m/s to 200 m/s (frequency-dependent) and from 0,5 mm to 1 000 mm. The limits of uncertainty applicable are ±0,5 % of reading.
Calibration of vibration and shock pick-ups - Method for primary vibration calibration at low frequencies
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of accelerometers using Earth's gravitation. This part of ISO 5347 applies to rectilinear acceler-ometers with zero-frequency response, mainly of the straingauge or piezoresistive type, to servopick-ups, and to primary standard and working pick-ups. It is applicable for ±local Earth's gravitation at 0 Hz. The limit of uncertainty applicable is ±0,01 m/s.
Calibration of vibration and shock pick-ups - Method for calibration by earth's gravitation
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary shock calibration of accelerometers by light cutting. It applies to rectilinear accelerometers of the strain gauge, piezoresistive and piezoelectric types and to primary standards. This part of ISO 5347 is applicable for a time range from 0,1 m/s to 10 m/s and a dynamic range from 100m/s to 10m/s. The limits of uncertainty applicable are ±3 % of the reading.
Calibration of vibration and shock pick-ups - Methods for primary shock calibration by light cutting
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for primary calibration of rectilinear accele-rometers using laser interferometry for dynamic dis-placement measurements. It is applicable for a frequency range from 20 Hz to 5 000 Hz and a dynamic range from 10 m/s to 1 000 m/s (frequency-dependent). The limits of uncertainty applicable are as follows: ±0,5 % of reading at reference frequency (160 Hz or 80 Hz) and reference amplitude (100 m/s or 10 m/s) and reference amplifier gain setting; ±1 % of reading for frequencies ≤ 1 000 Hz; ±2 % of reading for frequencies > 1 000 Hz.
Calibration of vibration and shock pick-ups. Methods for primary vibration calibration by laser interferometry
Provides a technique for the calibration of a hydrophone by means of a transducer of known output power.
Specification for absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz
ISO 5347 comprises a series of documents dealing with methods for the calibration of vibration and shock pick-ups. This part of ISO 5347 lays down detailed specifi-cations for the instrumentation and procedure to be used for base strain sensitivity testing. It applies to rectilinear accelerometers, mainly of the piezoelectric type. This part of ISO 5347 is applicable for the following parameters: a) Reference values: — pick-up base radius of curvature: 25 m — base strain: 2,5 × 10 b) Check values: — radius of curvature 62,5 m, strain of base 1 × 10 — radius of curvature 12,5 m, strain of base 5×10
Calibration of vibration and shock pick-ups. Method of test for base strain sensitivity
Acoustics. Determination of sound power radiated into a duct by fans. In-duct method.
Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHzto 15 MHz.
Meters to measure sound exposure as the time integral of the square of the instantaneous A-frequency-weighted sound pressure.
Electroacoustics - Specifications for personal sound exposure meters
Настоящий стандарт распространяется на государственную поверочную схему для средств измерении звукового давления в воздушной среде в ди
State system for ensuring the uniformity of measurements. State verification schedule for means measuring the airborne sound pressure in the frequencys range 2 Hr -100 kHr
The primary purpose is to ensure the accuracy of measurements of sound intensity applied to the determination of sound power in accordance with ISO 9614-1. Specifies performance requirements for instruments used for the measurement of sound intensity, an
Electroacoustics; instruments for the measurement of sound intensity; measurement with pairs of pressure sensing microphones
Specifies requirements for audiometers or parts thereof designed to provide a means of presenting speech sounds to a subject in a standardized manner, e.g. for the measurement of speech recognition. The purpose is to ensure that tests of hearing using sp
Audiometers; part 2: equipment for speech audiometry
Acoustics. Measurement of sound absorption in a reverberation room.
Integrating-averaging sound level meters; amendment 2
Sound level meters; amendment 1