共找到 142 条与 供、配电工程 相关的标准,共 10 页
本规范适用于1 lOkV及以下的供配电系统新建和扩建工程的设计。
Code for design of electric power supply systems
本规范适用于新建、扩建的矿L【j工程电力设计,不适用于石油矿电力没计。
Code for power design of mine
本规范适用于工业与民用新建和扩建工程的通用用电设备配电设计。
Code for design of electric distribution of general-purpose utilization equipment
本规范适用于电压为35—110kV,单台变压器容量为5000kVA及以上新建变电所的设计。
Design code for substation(35~110kv)
本规范适用于各行业3N llokV电力线路和设备,单机容量为25MW及以下发电机,63MVA及以下电力变压器等电力装置的继电保护和自动装置的设计。
Design code for relaying protection and automatic device of electric power installation
Green power traceability method for power trading users
Technical specifications for installation and installation of multifunctional light poles in Chengdu
本文件适用于深圳市20kV及以下电力用户侧智能配电站的智能化建设、改造、运维和管理。
User intelligent distribution station system construction specification
本规程适用于竣工验收交付使用的电压为10KV及以下城市道路(隧道、桥梁)照明设施的养护工作。
Maintenance rules for urban road lighting facilities
本标准适用于江苏省行政区域内,采用钢轮钢轨系统和全封闭线路条件下,采用A型或B型车辆,设计最高运行速度不大于100km/h的新建城市轨道交通工程的设计。
Design Standards for Urban Rail Transit Engineering in Jiangsu Province
本标准规定了电力地下管线跟踪测量、要素采集和成果检查验收的技术要求。 本标准适用于电力地下管线的跟踪测量、要素采集及成果检查验收。
Technical requirements for power underground pipeline measurement and element collection
本标准规定了电力地下管线竣工图绘制和验收的技术要求。 本标准适用于电力地下管线(以下简称“管线”)的竣工图绘制及竣工验收。
Technical Requirements for As-built Drawings of Electric Power Underground Pipelines
Low voltage electrical installations - Part 6: Verification; Corrigendum 1
Electricity metering data exchange - The DLMS/COSEM suite - Part 4-7: DLMS/COSEM transport layer for IP networks (IEC 62056-4-7:2015); English version EN 62056-4-7:2016
Electricity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer (IEC 62056-5-3:2016); English version EN 62056-5-3:2016
Electricity metering data exchange - The DLMS/COSEM suite - Part 6-2: COSEM interface classes (IEC 62056-6-2:2016); English version EN 62056-6-2:2016
This part of the IEC 61084 series specifies requirements and tests for cable trunking systems (CTS) and cable ducting systems (CDS) intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1000 V AC and 1500 V DC. This document does not apply to conduit systems, cable tray systems, cable ladder systems, power track systems or equipment covered by other standards. NOTE This part of the IEC 61084 series is not intended to be used by itself.
Cable trunking systems and cable ducting systems for electrical installations - Part 1: General requirements
Electricity metering data exchange. The DLMS/COSEM suite. DLMS/COSEM transport layer for IP networks
Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances; Amendment 1; Corrigendum 1
本标准的适用范围为住宅小区内供配电设施建设,设计范围为电网电源点至用户计量表计。
Construction standards for power supply and distribution facilities in residential quarters
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号