Q14 混凝土制品 标准查询与下载



共找到 1595 条与 混凝土制品 相关的标准,共 107

Precast concrete products -- General rules for method of inspection

ICS
91.100.30;93.080.30
CCS
Q14
发布
2016-04-20
实施

Precast concrete products -- Required performance and methods of verification

ICS
91.100.30;93.080.30
CCS
Q14
发布
2016-04-20
实施

Precast concrete products -- General rules for methods of performance test

ICS
91.100.30;93.080.30
CCS
Q14
发布
2016-04-20
实施

Precast concrete products -- General rules of materials and product methods

ICS
91.100.30;93.080.30
CCS
Q14
发布
2016-04-20
实施

Precast concrete products -- General rules for classification, designation and marking

ICS
91.100.30;93.080.30
CCS
Q14
发布
2016-04-20
实施

Design and use of inserts for lifting and handling of precast concrete elements

ICS
91.100.30
CCS
Q14
发布
2016-03-31
实施
2016-03-31

This European Standard specifies a procedure for carrying out impressed current electrochemical realkalization (ER) of carbonated reinforced concrete in existing structures. It is applicable to atmospherically exposed parts of structures with ordinary reinforcement embedded in concrete. This European Standard does not apply to concrete containing prestressing steel which can suffer hydrogen embrittlement during realkalization, or to concrete containing epoxy-coated or galvanized reinforcement, or if chloride contamination is contributing to reinforcement corrosion. NOTE In case of post-tensioned prestressing concrete, the endangered tendon strands may be shielded by the tendon ducts from unwanted and/ or exceeded polarization into the cathodic range and respective water reduction.

Electrochemical realkalization and chloride extraction treatments for reinforced concrete - Part 1: Realkalization

ICS
91.080.40
CCS
Q14
发布
2016-03
实施

Safety production specifications for precast concrete lining segments

ICS
91.100.40
CCS
Q14
发布
2016-01-15
实施
2016-07-01

1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water. 1.2 This specification is the metric counterpart of Specification C1504; therefore, no imperial (metric) equivalents are presented in this specification. Note 1: This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the geometric section specified and provisions for inspection at the construction site are required. 1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains (Metric)

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the SI companion to Specification C1433. Note 1: This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers (Metric)

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water industrial wastes and sewage. 1.2 This specification is the SI companion to Specification C1433. Note 1: This specification is primarily a manufacturing and purchasing specification. However, standard designs are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends upon the proper selection of the box section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete box sections specified herein is cautioned that he must properly correlate the loading conditions and the field requirements with the box section specified and provide for inspection at the construction site.

Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers (Metric)

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers single-cell precast conventionally reinforced concrete three-sided structures intended to be used for the construction of culverts and for the conveyance of storm water. 1.2 A complete metric companion to Specification C1504 has been developed—C1504M; therefore, no metric equivalents are presented in this specification. Note 1: This specification is primarily a manufacturing and purchasing specification. The successful performance of this product depends upon the proper selection of the geometric section, bedding, backfill, and care that the installation conforms to the construction specifications. The purchaser of the precast reinforced concrete three-sided structure specified herein is cautioned that proper correlation of the loading conditions and the field requirements with the geometric section specified and provisions for inspection at the construction site are required. 1.3 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

Standard Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers prefaced concrete and calcium silicate masonry units with the finished face(s) covered at the point of manufacture with resin, resin and inert filler, or cement and inert filler to produce a smooth tile-like surface feature. This specification does not address, and therefore is not applicable to, ground-face concrete masonry units that are manufactured by grinding a thin layer off the surface of a concrete masonry unit to expose aggregates within and polishing to produce a smooth, architectural finish. 1.2 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units

ICS
91.100.15 ; 91.100.30
CCS
Q14
发布
2016
实施

1.1 This specification covers materials in sheet form used for covering the surfaces of hydraulic cement concrete to inhibit moisture loss during the curing period and, in the case of the white reflective type materials, to also reduce temperature rise in concrete exposed to radiation from the sun. The following types are included: 1.1.1 Curing Paper:  1.1.1.1 Regular. 1.1.1.2 White. 1.1.2 Polyethylene Film:  1.1.2.1 Clear. 1.1.2.2 White Opaque. 1.1.3 White-Burlap-Polyethylene Sheet. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1: This specification does not cover materials such as burlap, cotton mats, or rugs used with additional applications of water to maintain a water-saturated environment on such surfaces. Sheet materials having additional characteristics such as insulating properties and the ability to carry additional water to the curing region are commercially available but are not currently addressed in this specification. 1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes shall not be considered as requirements of the standard.

Standard Specification for Sheet Materials for Curing Concrete

ICS
91.100.30
CCS
Q14
发布
2016
实施

1.1 This specification covers reinforced concrete pipe intended to be used for the conveyance of sewage, industrial wastes, and storm water, and for the construction of culverts. 1.2 This specification is the inch-pound companion to Specification C76M; therefore, no SI equivalents are presented in this specification. Reinforced concrete pipe that conform to the requirements of C76M, are acceptable under this Specification C76 unless prohibited by the Owner. Note 1: This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site. Note 2: Attention is called to the specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (Specification C655).

Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe

ICS
23.040.50
CCS
Q14
发布
2016
实施

1.1 This specification covers the requirements for concrete grid paving units for vehicular trafficways, parking areas, soil stabilization, and revetments. Note 1: When particular features are desired, such as weight classification, higher compressive strength, surface texture, finish, color, or other special features, such properties should be specified separately by the purchaser. However, local sellers should be consulted as to availability of units having the desired features. 1.2 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Concrete Grid Paving Units

ICS
91.100.30
CCS
Q14
发布
2016
实施

Prefabricated concrete and reinforced concrete constructions and products. Symbols (marks)

ICS
01.075;91.080.40;91.100.30
CCS
Q14
发布
2016
实施
2017-01-01

1.1 This specification covers hollow and solid (see 5.3 and 5.4) concrete masonry units made from hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. There are three classes of concrete masonry units: Normal Weight, Medium Weight, and Lightweight. These units are suitable for both loadbearing and nonloadbearing applications. 1.2 Concrete masonry units covered by this specification are made from lightweight or normal weight aggregates, or both. Note 1: The requirements of this specification have been researched, evaluated, and established for over a century, resulting in the physical properties and attributes defined here. These requirements are uniquely and solely applicable to concrete masonry units manufactured on equipment using low or zero slump concrete and the constituent materials defined herein. Many performance attributes of concrete masonry units are indirectly accounted for, or inherently reflected within, the requirements of this specification without direct measurement, assessment, or evaluation. Applying the requirements of this specification to products that may be similar in appearance, use, or nature to those covered by this specification may not address all pertinent physical properties necessary to ensure performance or serviceability of the resulting construction in real-world applications under typical exposure environments. Products manufactured using alternative materials, manufacturing methods, or curing processes not covered by this specification should not be evaluated solely using the requirements in this specification; however, developers of new products can consider the property requirements of this specification as a beginning benchmark for unit performance. It is reasonable to test new products for system performance as well as unit performance. 1.3 The text of this specification references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. Note 2: When particular features are desired such as surface textures for appearance or bond, finish, color, or particular properties such as density classification, higher compressive strength, fire resistance, thermal performance or acoustical performance, these features should be specified separately by the purchaser. Suppliers should be consulted as to the availability of units having the desired features.

Standard Specification for Loadbearing Concrete Masonry Units

ICS
91.100.30
CCS
Q14
发布
2016
实施

1.1 This specification covers the minimum technical requirements for lathing and furring for the application of exterior and interior portland cement-based plaster, as in Specifications C841 or C926. These requirements do not by default define a unit of work or assign responsibility for contractual purposes, which is the purview of a contract or contracts made between contracting entities. 1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed. 1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable requirements of Test Method E90. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster

ICS
91.100.10
CCS
Q14
发布
2016
实施

1.1 These test methods cover testing of concrete pipe, manhole sections, and tile. The test methods described are used in production testing and acceptance testing to evaluate the properties provided for in the specifications. 1.2 The test methods appear in the following order:   Section External Load Crushing Strength  4 Flat Slab Top  5 Core Strength  6 Absorption  7 Hydrostatic  8 Permeability Manhole Step  9 10 Cylinder Strength 11 Gasket Lubricant 12 Joint Shear 13 Alkalinity 14 Gasket Measurements 15 1.3 The test specimens shall not have been exposed to a temperature below 40°F for the 24 h immediately preceding the test. 1.4 If any test specimen fails because of mechanical reasons such as failure of testing equipment or improper specimen preparation, it s......

Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile

ICS
23.040.50
CCS
Q14
发布
2016
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved