This article concerns the flame dynamics of a bluff body stabilized turbulent premixed flame as it approaches lean blowoff. Time resolved chemiluminescence imaging along with simultaneous particle image velocimetry and OH planar laser-induced fluorescence were utilized in an axisymmetric bluff body stabilized, propane-air flame to determine the sequence of events leading to blowoff and provide a quantitative analysis of the experimental results. It was found that as lean blowoff is approached by reduction of equivalence ratio, flame speed decreases and the flame shape progressively changes from a conical to a columnar shape. For a stably burning conical flame away from blowoff, the flame front envelopes the shear layer vortices. Near blowoff, the columnar flame front and shear layer vortices overlap to induce
high local stretch rates that exceed the extinction stretch rates instantaneously and in the mean, resulting in local flame extinction along the shear layers. Following shear layer extinction, fresh reactants can pass through the shear layers to react within the recirculation zone with all other parts of the flame extinguished.
This flame kernel within the recirculation zone may survive for a few milliseconds and can reignite the shear layers such that the entire flame is reestablished for a short period. This extinction and reignition event can happen several times before final blowoff which occurs when the flame kernel fails to reignite the shear layers and ultimately leads to total flame extinguishment.
FlowMaster High-Speed 系统为流体动力学分析提供了新的研究手段。它同时提供了基于数字PIV的空间流场信息和每一点随时间的演化信息。
测试系统功能和性能指标:
系统功能:
FlowMaster-TR粒子测速仪LaVision 非流线体稳定的湍动预混火焰的吹灭动力学信息由北京欧兰科技发展有限公司为您提供,如您想了解更多关于FlowMaster-TR粒子测速仪LaVision 非流线体稳定的湍动预混火焰的吹灭动力学报价、型号、参数等信息,欢迎来电或留言咨询。