您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
瀚宇科技(香港)有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > 瀚宇科技(香港)有限公司 > 拉曼光谱仪 > QE65000-Raman拉曼科学级光谱仪

QE65000-Raman拉曼科学级光谱仪

参考报价: 面议 型号: QE65000
品牌: 暂无 产地: 暂无
关注度: 78 信息完整度:
样本: 典型用户: 暂无
咨询留言 在线咨询

400-6699-1171000

QE65000型科学级光谱仪是探测器,光学平台和电子器件等技术的全新结合,为用户提供高灵敏的系统,以满足在低亮度下的应用。QE65000型科学级光谱仪的量子效率可达90%,并具有很高的信噪比和快速的信号处理能力。

 
产品特点:
  • 量子效率可达90%
  • 更高的系统灵敏度
  • 优秀的紫外响应能力
  • 板载微控制器
  • 满足低亮度级别应用的条件
  • 即插即用USB操作
 

Optical Bench Enhancements

The great performance of our QE65000-Raman Spectrometer has been enhanced to provide even more value: lower stray light, improved efficiency in the UV and Shortwave NIR, and better unit-to-unit reproducibility.
We are also offering a proprietary low BRDF bench coating to improve stray light performance and provide better reproducibility in unit-to-unit performance.

Quantum Efficiency to 90%

The QE65000 is the most sensitive spectrometer we have ever developed. The Hamamatsu FFT-CCD detector used in the QE65000-Raman provides 90% quantum efficiency (defined as how efficiently a photon is converted to a photo-electron). Most of our other detectors are linear CCDs but with this “2D” area detector, we can bin (or sum) a vertical row of pixels, which offers significant improvement in the signal-to-noise ratio (>1000:1) and signal processing speed of the detector compared with a linear CCD, where signals are digitally added by an external circuit.

Increased System Sensitivity

In our spectrometers with linear CCDs, the slit’s width, not its height, regulates the amount of light entering the bench because linear CCDs cannot efficiently collect the light from the entire height of the slit. But in the QE65000, the 2D area detector can better take advantage of the height of the slit and the additional light, greatly improving system sensitivity.

Excellent UV Response

Because the detector in the QE65000-Raman is back-thinned (or back-illuminated), it has great native response in the UV and does not require the additional coatings that we typically apply to other detectors for UV applications.

Demanding Low Light-level Applications

The QE65000-Raman Spectrometer is a great option for low-light level Raman spectroscopy. The TE-cooled (down to -15 °C) detector features low noise and low dark signal, which enables low-light-level detection and long integration times (analogous to the shutter speed of a camera) from 8 milliseconds to 15 minutes, with virtually no spectral distortion.

Onboard Programming

The QE65000-Raman also has an onboard programmable micro-controller for controlling the spectrometer and accessories. You have access to 10 user-programmable digital inputs/outputs and a pulse generator for triggering other devices. You can use the I/Os to flash a lamp, stop/start a process, and send a message/alarm during the spectrometer’s integration period. The spectrometer’s operating parameters can be controlled through software. In fact, wavelength calibration coefficients unique to each spectrometer are programmed into a memory chip right on the spectrometer.

Plug-and-Play USB Operation

The QE65000-Raman interfaces to a computer via USB 2.0 or RS-232 serial port. Data unique to each spectrometer are programmed into a memory chip on the QE65000; our SpectraSuite Spectroscopy Operating Software reads these values for easy setup and hot swapping among computers, whether they run on Linux, Mac or Windows operating systems.
 

Specifications


Physical
Dimensions: 182 mmx 110 mm x 47 mm
Weight: 1.18 kg(without power supply)
Detector
Detector: HamamatsuS7031-1006
Detector range: 200-1100 nm
Pixels: 1024 x 58 (1044 x 64 total pixels)
Pixel size: 24.576 μm2
Pixel well depth: 1000 Ke-
Sensitivity: ~0.065 counts / e-
Quantum efficiency: 90% peak; 65% at 250 nm
Optical Bench
Design: f/4, Symmetrical crossed Czerny-Turner
Focal length: 101.6 mminput and output
Entrance aperture: 50 µm wide slit
HC6 grating: provides 123-170 nm range
Detector collection lens option: None
Collimating and focusing mirrors: Standard only
UV enhanced window: No
Fiber optic connector: SMA 905 to 0.22 numerical aperture single-strand optical fiber
Spectroscopic
Wavelength range: 780 - 1100 nm (Grating dependent)
Optical resolution: ~6- 19cm-1 (Slit dependant)
Signal-to-noise ratio: 1000:1 (at full signal)
A/D resolution: 16 bit
Dark noise: 3 RMS counts
Dynamic range: 7.5 x 109 (system), 25000:1 for a single acquisition
Integration time: 8 ms to 15 minutes
Stray light: <0.08% at 600 nm; 0.4% at 435 nm
Corrected linearity: >99.8%
Electronics
Power consumption: 500 mA @ 5 VDC (no TE cooling); 3.5 A @ 5 VDC (with TE cooling)
Data transfer speed: Full scans to memory every 7 ms with USB 2.0 port, 18 ms with USB1.1 port, 300 ms with serial port
Inputs/Outputs: 10 onboard digital user-programmable GPIOs (general purpose inputs/outputs)
Analog channels: No
Auto nulling: Yes
Breakout box compatibility: Yes, HR4-BREAKOUT
Trigger modes: 4 modes
Strobe functions: No
Gated delay feature: Yes
Connector: 30-pin connector
Power-up time: <5 seconds
Dark current: 4000 e-/pixel/sec @ 25 ºC; 200 e-/pixel/sec @ 0 ºC
Computer
Operating systems: Windows 98/Me/2000/XP, Mac OS X and Linux with USB port; Any 32-bit Windows OS with serial port
Computer interfaces: USB 2.0 @ 480 Mbps; RS-232 (2-wire) @ 115.2 K baud
Peripheral interfaces: SPI (3-wire); I2C inter-integrated circuit
Temperature and Thermoelectric (TE) Cooling
Temperature limits: 0 ºC to 50.0 ºC; no condensation
Set point: Software controlled; lowest set point is 40 ºC below ambient
Stability +/-0.1 ºC of set temperature in <2 minutes

QE65000-Raman拉曼科学级光谱仪信息由瀚宇科技(香港)有限公司为您提供,如您想了解更多关于QE65000-Raman拉曼科学级光谱仪报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

QE65000-Raman拉曼科学级光谱仪 - 产品推荐
移动版: 资讯 直播 仪器谱

Copyright ©2007-2023 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号