您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
天津多为莱博科技有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > GMW > 美国GMW电磁铁 > 美国GMW 粒子束诊断

美国GMW 粒子束诊断

参考报价: 面议 型号: Particle Beam Diagnostics
品牌: GMW 产地: 美国
关注度: 378 信息完整度:
样本: 典型用户: 暂无
价格范围10万-30万组件类别光学元件
咨询留言 在线咨询

400-6699-1171000

AI问答
可以做哪些实验,检测什么? 可以用哪些耗材和试剂?



Bergoz IPCT DC/AC Current Transducer


Bergoz FCT Current Transformer


Bergoz NPCT

High sensitivity for low current. Differential and net current measurements of multiple conductors. Large internal diameter enables high voltage isolation.


The Fast Current Transformer (FCT) is a wideband AC transformer with a rise time down to 175ps and a bandwidth up to 2GHz.


The New Parametric Current Transformer (NPCT) is a zero-flux DC current transformer.

•Peak Current: ±10mA .. ±5000mA
•Resolution: 10uA
•Bandwidth: DC – 4.2kHz


•Bandwidth up to 1.75GHz 200-ps risetime
•Droop down to 0.1%/μs down to 160 Hz lower cutoff freqency
•Extra-high sensitivity up to 5 V/A


•Full scale range from ±20mA to ±20A controlled by TTL levels
•5 μA/sqrt(Hz) resolution in every range
•1 μA/sqrt(Hz) or lower resolution on option








Bergoz CWCT


Bergoz ACCT


Bergoz ICT, Turbo-ICT, BCM

The CWCT is a current transformer with strict limits on lower and upper cut-off frequencies, tailored to the beam RF.


The ACCT is non-interceptive current transformer.


The Integrating Current Transformer (ICT) is a capacitively shorted transformer and a fast read out transformer in a common magnetic circuit designed to measure the charge in a very short pulse with high accuracy.

•Beam repetition frequency 60~500 MHz
•Average current with 1 μA resolution
•Fast beam loss interlock 1 μs
•Linearity error <1.5%
•Beam loss resolution <1 %


•Output current range range from ±10mA to ±2A full scale.
•Frequency response from 5Hz to 350kHz
•DC current up to 1A does not saturate the sensor
•Radiation hard sensors available.


•Integrates a very fast pulse with rise time in the order of picoseconds with no significant loss








Bergoz MX-BPM / LR-BPM


Bergoz S-BPM


Bergoz VWM

The Bergoz Multiplexed Beam Position Monitor (MX-BPM) is an electronics module…


The S-band / L-band Beam Position Monitor (S–BPM) is an electronics module for fast analog processing of beam pickups signals.


The VWM is based on the wire resonant frequency dependence on its tension, itself dependent on its temperature

•On-board microstrip filters that elminate the need for costly tubular filters
•GaAs switches to provide superior button to button isolation and low insertion loss
•On-board systhesized local oscillator


•Non-interceptive beam position measurement.
•Beam charge range > 1000.


•Transverse profile and position monitor
•Fixed multi-wire sensor or moving sensor
•For beams: Photon from infrared to keV, Electron, proton from keV to GeV and Neutrons


美国GMW 粒子束诊断信息由天津多为莱博科技有限公司为您提供,如您想了解更多关于美国GMW 粒子束诊断报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

美国GMW 粒子束诊断 - 产品推荐
美国GMW 粒子束诊断 - 相关产品
移动版: 资讯 直播 仪器谱

Copyright ©2007-2023 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号