我的咨询

您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
咨询列表
法国Cameca公司/CAMECA中国
X
头像

客服中心

如果企业客服不在线,也可拨打400电话联系。或者发布求购信息

400-6699-117转1000
发布求购 实验百科采购-随时微信沟通
扫码关注
实验采购百科
您现在所在的位置:首页 >> 仪器导购 >> ICP-MS>> Plasma 3 MC-ICP-MS

Plasma 3 MC-ICP-MS

tel: 400-6699-117 1000

Nu InstrumentsICP-MS, 该仪器保留了独特的,zl的可变色散变焦镜头,可同时测量从十六个法拉第检测器和多达六个离子计数检测器的静态收集器阵列上的锂元素到锕系元素的元素同位素。

咨询留言

技术特点

【技术特点】-- Plasma 3 MC-ICP-MS

所有新的ICP源

多重探测器

增强型丰度转移光学(EATO)


主要特征
双重聚焦高精度同位素测量质谱仪
增强灵敏度接口作为标准
EATO  - 增强型丰富转移光学(zl申请中)
具有“频率调谐”功能的强大的第三代射频发生器

所有新的,创新的火炬箱设计,可轻松连接各种样品引入装置

全干泵送配置可用

zei多六个离子计数检测器(具有SEM / Daly选项)

高分辨率和伪高分辨率功能

高丰度减速过滤器可提高丰度灵敏度

十六大动态范围法拉第检测器,带可选软件可切换电阻放大器


All new ICP source

The ICP source has been designed and engineered to be robust while ensuring maximum stability and reliability during operation. This unique design of ICP source gives the user unrestricted access to the interface area to facilitate ease of use and maintenance

Multiple Daly Detectors

Multiple Daly detectors can be substituted for SEM detectors on Plasma 3; up to three on the standard instrument. A full Daly collector system is also available on the ‘D’ variant of the instrument for the ultimate in ion counting performance. This can include up to six Daly Detectors in addition to the sixteen Faraday cups.

Enhanced Abundance Transfer Optics (EATO)

For the more demanding actinide applications an additional lens element EATO (patent pending) has been designed, easily installed by users without the need to vent the analyser. This device is inserted in to the transfer chamber and provides significant improvement to the abundance sensitivity without compromising transmission or mass bias stability.

Key Features

  • Double focussing high precision isotopic measurement mass spectrometer

  • Enhanced Sensitivity Interface as standard

  • EATO – Enhanced Abundance Transfer Optics (patent pending)

  • Robust third generation RF generator with “Frequency Tuning”

  • All new, innovative torch box design allowing easy connection of a wide range of sample introduction devices

  • Fully Dry Pumped configuration available

  • Up to six ion-counting detectors (with SEM / Daly options)

  • High resolution and pseudo high resolution capabilities

  • High abundance deceleration filters available for improved abundance sensitivity

  • Sixteen large dynamic range Faraday detectors, with optional software switchable resistor amplifiers



【技术特点对用户带来的好处】-- Plasma 3 MC-ICP-MS


【典型应用举例】-- Plasma 3 MC-ICP-MS



厂家资料

地址:北京酒仙桥京东方大厦2层西侧

电话:400-6699-117 转 1000

经销商

售后服务

我会维修/培训/做方法

如果您是一名工程师或者专业维修科学 仪器的服务商,都可参与登记,我们的平台 会为您的服务精确的定位并展示。

1该产品的品牌知名度如何?
2你对该产品的使用感受如何?
3该产品的性价比如何?
4该产品的售务如何?
查看
在线咨询

在线咨询时间:

周一至周五

早9:00 - 晚17:30

若您在周六周日咨询,请直接留言您所咨询的产品名称+联系人+电话