NEMA AB-5-2011
建立低压断路器的选择性配合等级

Establishing Levels of Selective Coordination for Low Voltage Circuit Breakers


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 NEMA AB-5-2011 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
NEMA AB-5-2011
发布
2011年
发布单位
NEMA - National Electrical Manufacturers Association
 
 
适用范围
The scope of this standard includes all types of circuit breakers listed to: 1) The UL 489 Molded-Case Circuit Breakers@ Molded-Case Switches and Circuit-Breaker Enclosures 2) The UL 1066 Standard for Safety Low-Voltage AC and DC Power Circuit Breakers Used in Enclosures The standard specifically addresses achieving selective coordination at high levels of short circuit fault current in the instantaneous region of the circuit breaker time-current curve by use of selective coordination tools. This requires taking into consideration more information than is typically found on conventional Time-Current Curves TCCs only. This includes molded case circuit breakers and insulated case circuit breakers. It specifically addresses instantaneous selective coordination as achieving selective coordination at high levels of fault current@ and may require taking into consideration more information than is typically found on conventional TimeCurrent Curves TCCs only. 1.2 Referenced Standards In this publication@ reference is made to the latest edition of the standards listed below. Copies are available from the indicated sources. Other references are listed at the end of this standard. National Electrical Manufacturers Association 1300 North 17th Street Rosslyn@ Virginia 22209 AB 1 ABP 1 Molded Case Circuit Breakers@ Molded Case Switches and Circuit Breaker Enclosures Selective Coordination National Fire Protection Association Batterymarch Park Quincy@ MA 02269 NFPA 70 National Electrical Code ?? 1

NEMA AB-5-2011相似标准


推荐

微型断路器选用及工程设计要点

(5) 断路器与熔断器配合使用时应考虑上下级配合,应将断路器安秒特性曲线与熔断器安秒特性曲线比较,以使在发生短路电流情况下,具有保护选择性。  (6) 断路器作配电线路保护时,宜选用带长延时动作过流脱扣器断路器,当线路末端发生单相接地短路时,短路电流不小于断路器瞬时或短延时过流脱扣器整定电流1.5 倍。...

框架式断路器选用及工程设计要点

(5) 断路器与熔断器配合使用时应考虑上下级配合,应将断路器安秒特性曲线与熔断器安秒特性曲线比较,以使在发生短路电流情况下,具有保护选择性。  (6) 断路器作配电线路保护时,宜选用带长延时动作过流脱扣器断路器,当线路末端发生单相接地短路时,短路电流不小于断路器瞬时或短延时过流脱扣器整定电流1.5 倍。...

断路器主要技术性能和参数

额定电流大断路器操作循环次数较少,额定电流小断路器则较多。  10、 [公式] 特性  [公式] 表示与分断时间有关 [公式] 最大值与预期电流(交流对称有效值)函数关系(一般为一条曲线),预期电流可至最大值,是相应于额定短路分断能力及有关电压预期电流。特别是对限流断路器有较重要意义,在选择性配合中可作为配合协调依据。  11、可通信能力  随着智能型断路器出现,引发出可通信问题。...

断路器选择性与级联保护性

一般来说,要保证上下两级低压断路器之间选择性动作,上一级断路器宜选择带短延时过流脱扣器,而且其动作电流要大于下一级过流脱扣器动作电流一级以上,至少上一级动作电流Iop.1不小于下一级动作电流Iop.21.2倍,即Iop1≥1.2Iop.2。  断路器级联保护性  在配电系统设计中,断路器上下两级之间选择性配合,必须具有“选择性、快速性和灵敏性”。  ...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号