Nuclear facilities. Instrumentation systems important to safety. Radiation monitoring for accident and post-accident conditions - Equipment for continuous high range area gamma monitoring
1 Scope
This part of IEC 60951
provides general guidance on the design principles and performance criteria for equipment
for continuous high range area gamma monitoring in nuclear facilities for accident
and post-accident conditions. This document categorizes accident conditions into design
basis accidents (DBA) and design extension conditions (DEC), including severe accident
(SA).
General requirements for technical characteristics, test procedures, radiation characteristics,
electrical, mechanical, and environmental characteristics are given in IEC 60951‑1. These requirements are applicable in this document, unless otherwise stated.
The purpose of this document is to lay down general requirements for equipment for
continuous high range area gamma monitoring of radiation within the facility during
and after accident conditions in nuclear facilities.
This document is applicable to installed dose rate meters that are used to monitor
high levels of gamma radiation during and after an accident. It covers equipment intended
to isotropically measure air kerma, ambient dose or other exposure quantities due
to gamma radiation of energy between 80 keV and 7 MeV. The equipment is intended primarily
for the purpose of nuclear facility safety.
Portable instruments for emergency purposes and installed area radiation monitors
used to determine continuously the radiological situation in working areas during
normal operation are in the scope of IEC 60532.