适用范围

5.1 This test method provides a means to measure low infiltration rates associated with fine-grained, clayey soils, and are in the range of 18201;×8201;10−5 cm/s to 18201;×8201;10−8 cm/s.

5.2 This test method is particularly useful for measuring liquid flow through soil moisture barriers such as compacted clay liner or covers used at waste disposal facilities, for canal and reservoir liners, for seepage blankets, and for amended soil liners such as those used for retention ponds or storage tanks.

5.3 The purpose of the sealed inner ring is to: (1) provide a means to measure the actual amount of flow rather than a drop in water elevation which is the flow measurement procedure used in Test Method D3385 and (2) to eliminate evaporation losses.

5.4 The purpose of the outer ring is to promote one-dimensional, vertical flow beneath the inner ring. The use of large diameter rings and large depths of embedments helps to ensure that flow is essentially one-dimensional.

5.5 This test method provides a means to measure infiltration rate over a relatively large area of soil. Tests on large volumes of soil can be more representative than tests on small volumes of soil.

5.6 The data obtained from this test method are most useful when the soil layer being tested has a uniform distribution of pore space, and when the density and degree of saturation and the hydraulic conductivity of the material underlying the soil layer are known.

5.7 Changes in water temperature can introduce significant error in the volume change measurements. Temperature changes will cause water to flow in or out of the inner ring due to expansion or contraction of the inner ring and the water contained within the inner ring.

5.8 The problem of temperature changes can be minimized by insulating the rings, by allowing enough flow to occur so that the amount of flow resulting from a temperature change is not significant compared to that due to infiltration, or by connecting and disconnecting the bag from the inner ring when the water in the inner ring is at the same temperature.

5.9 If the soil being tested will later be subjected to increased overburden stress, then the infiltration rate can be expected to decrease as the overburden stress increases. Laboratory hydraulic conductivity tests are recommended for studies of the influence of level of stress on the hydraulic properties of the soil.

Note 1: The quality of the result produced by this standard depends on the competence of the personnel performing it and the suitability of the equipment and facilities being used. Agencies that meet the criteria of Practice


推荐

DJ-IN12-W入渗

  用途:DJ-IN12-W入渗是一种简单设备,用来测量水渗入土壤渗透速度。渗透速率是指单位时间内单位表面积水渗入量。通过测量结果和达西定律可以计算出该入渗速率。   标准装置包括数套不同直径不锈钢,可同时进行几个测量,以得到正确可靠结果。垂直渗透水流向边缘时,入渗外环就可以起到隔离作用。由于内环水是垂直流动,因而测量仅限于在内环中进行。...

入渗概述和特点

  入渗是一种简单设备,用来测量水渗入土壤渗透速度。渗透速率是指单位时间内单位表面积水渗入量。通过测量结果和达西定律可以计算出该入渗速率。标准装置包括数套不同直径不锈钢,可同时进行几个测量,以得到正确可靠结果。垂直渗透水流向边缘时,入渗外环就可以起到隔离作用。由于内环水是垂直流动,因而测量仅限于在内环中进行。...

春节“囤菜”指南 | 你一定要试试神奇密封

TMI 撕裂度厚度大小和均匀是软包材料具有特定保护功能先决条件之一,是关系着后期材料使用各种力学强度性能重要影响因素之一。针对密封厚度,可以由领拓仪器代理Messmer Buchel薄膜测厚仪精确测量。设备符合ISO, ASTM, TAPPI等多种国际标准。此外,该厚度还可进行低压力、砝码压力及光学感应自动测量。...


ASTM D5093-15 中可能用到的仪器设备


谁引用了ASTM D5093-15 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号