1.1 This Standard applies to single phase and polyphase dry-type transformers, including those with cast or resin encapsulated coils, that are within the limits of the electrical ratings specified in Clauses 7.2 and 7.3, and that are intended for use in accordance with the service conditions for dry-type transformers specified in Annexes A and B. Notes: 1) For information on the loading of dry-type transformers, see IEEE C57.96. 2) For additional requirements for dry-type transformers in accordance with the Canadian Electrical Code, Part II, see CSA C22.2 No. 47. 1.2 This Standard deals with the standardization of voltage ratings, kVA capacities, other electrical features, certain mechanical features, and test procedures. 1.3 This Standard does not apply to transformers designed solely for test purposes, rectifier transformers, welding transformers, furnace transformers, instrument transformers, motor-starting autotransformers, or any other special purpose transformers. 1.4 In this Standard, the word “transformer” refers to a dry-type transformer, unless otherwise specifically stated. 1.5 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

CSA C9-17:2017相似标准


推荐

干式变压器相关问题探讨

因为这种结构不仅可以提高干式变压器的冷却性能和机械的强度,而且还可以大大提高干式变压器的耐压力。  除了绕组及铁芯,干式变压器还有绝缘结构。干式变压器的绝缘结构由内部绝缘和外部绝缘组成。对干式变压器的结构了解有助于加深对干式变压器的特点等方面的了解。  2、干式变压器的特点  干式变压器是一种将空气作为冷却介质的变压器,与油浸式变压器的冷却方式不同,它主要使用了自然风冷和强制风冷的冷却方式。...

干式变压器的选择

  干式变压器的正确选择对提高电力系统的安全稳定运行具有重要作用,在上文中我们已经了解干式变压器的结构和特点,这一部分我们将根据干式变压器的负载性质和使用环境两方面讲述如何选择干式变压器。  (1)根据电力的负荷性质进行选择。电力负荷的种类很多,不同的电力负荷要选用不同的干式变压器。...

干式变压器的组成结构

因为这种结构不仅可以提高干式变压器的冷却性能和机械的强度,而且还可以大大提高干式变压器的耐压力。  除了绕组及铁芯,干式变压器还有绝缘结构。干式变压器的绝缘结构由内部绝缘和外部绝缘组成。对干式变压器的结构了解有助于加深对干式变压器的特点等方面的了解。...

干式变压器的种类

  1、浸渍空气绝缘干式变压器:目前使用很少。绕组导线绝缘、绝缘结构材料根据需要选用不同耐热等级的绝缘材料,制成B级、F级和H级绝缘干式变压器。  2、环氧树脂浇注干式变压器:采用的绝缘材料有聚酯树脂和环氧树脂。目前浇注绝缘干式电力变压器多采用环氧树脂。  3、绕包绝缘干式变压器:绕包绝缘干式变压器也是树脂绝缘的一种,目前生产厂家较少。  ...