CSA C22.2 No.213-2016

Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA C22.2 No.213-2016 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA C22.2 No.213-2016
发布
2016年
发布单位
SCC
替代标准
CSA C22.2 No.213-2017
当前最新
CSA C22.2 No.213-2017
 
 
被代替标准
C22.2 NO. 213-M1987 (R2013)
适用范围
1.1 Purpose The purpose of this Standard is to provide minimum requirements for the design, construction, and marking of electrical equipment or parts of such equipment for use in Class I and Class II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations. This equipment, in normal operation, is not capable of causing ignition of the surrounding atmosphere under the conditions prescribed in this Standard, although the equipment could contain electronic components used in an incendive circuit and could also have field wiring that is an incendive circuit. In addition, it is the intent of this document to establish uniformity in test methods for determining the suitability of the equipment and associated circuits and components as they relate to potential ignition of a specific flammable gas or vapor-in-air mixture, combustible dust, easily ignitible fibers, or flyings. 1.2 Applicable to Class I and II, Division 2 and Class III, Divisions 1 and 2 locations This Standard applies only to equipment, circuits, and components for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations as defined in the National Electrical Code® (NEC®), ANSI/NFPA 70, or in the Canadian Electrical Code, Part I (CE Code Part I), CSA C22.1. Notes: 1) Some equipment designed for use in unclassified locations is permitted by the NEC® or CE Code Part I for installation in Division 2 locations. The judgment of acceptability for the installation would be determined by the authority having jurisdiction. Such equipment would not have the hazardous location marking or documentation described in this Standard. It is anticipated that such equipment would comply with the other requirements in this Standard and that the determination of compliance is elementary (e.g., a nonarcing instrument inside a Type 4 or Type 12 enclosure used in a Class II, Division 2 location). 2) Throughout this Standard, references to CAN/CSA-C22.2 No. 60079-0 and ANSI/ISA 60079-0 are made as “CSA/ISA 60079-0”. Similarly, references to CAN/CSA-C22.2 No. 60079-1 and ANSI/ISA 60079-1 are made as “CSA/ISA 60079-1”, references to CAN/CSA-C22.2 No. 60079-11 and ANSI/ISA 60079-11 are made as “CSA/ISA 60079-11”, and references to CAN/CSA-C22.2 No. 60079-15 and ANSI/ISA 60079-15 are made as “CSA/ISA 60079-15”. 3) The US and Canadian adoptions of IEC 60079-0, IEC 60079-1, IEC 60079-11 and IEC 60079-15 could be adopted at different revision levels and may have different National Deviations. 1.3 Applicable to associated nonincendive field wiring apparatus This standard also applies to associated nonincendive field wiring apparatus located in a non-hazardous (unclassified) location specifically designed to directly connect to nonincendive field wiring in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations. Note: The 2015 CE Code Part I does not address nonincendive field wiring circuits in Class II or Class III hazardous locations. 1.4 Applicable ambient conditions The requirements of this Standard are based on consideration of the following ambient conditions: a) a lower ambient temperature of -50 °C or higher; b) an upper ambient temperature of 40 °C or lower; c) an oxygen concentration of not greater than 21 percent by volume; and d) a pressure of 80 kPa (0.8 bar) to 110 kPa (1.1 bar). Note: Equipment specified for atmospheric conditions beyond the above limits could be subject to additional investigation. 1.5 Not applicable to specified ignition mechanisms This standard is not applicable to mechanisms of ignition from external sources, such as static electricity or lightning, that are not related to the electrical characteristics of the equipment. 1.6 Not applicable to specific products This standard does not apply to electric luminaires for use in Division 2 hazardous (classified) locations. This standard does not apply to electric motors, electric heaters, heat tracing cables, and similar heatproducing products, except where they are an integral part of the equipment under evaluation, for use in Division 2 locations. Where electric motors, electric heaters, heat tracing cables, or similar heatproducing products are an integral part of the equipment under evaluation, applicable requirements from the Division 2 hazardous locations standards for these products shall be considered. In the United States, this Standard does not apply to battery-operated flashlights and lanterns within the scope of ANSI/UL 783.

CSA C22.2 No.213-2016相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号