ACI 364.17T-2018
如何在安装地板覆盖物之前测量混凝土表面的 pH 值

How to Measure pH of a Concrete Surface prior to Installation of a Floor Covering


ACI 364.17T-2018




购买全文,请联系:


标准号
ACI 364.17T-2018
发布
2018年
发布单位
ACI - American Concrete Institute
 
 
适用范围
Introduction A review of published literature indicates that there is plenty of information regarding the pH of concrete as it relates to carbonation@ embedded steel corrosion@ alkali-silica reaction@ and effects of mineral admixtures such as fly ash and silica fume. There are@ however@ only a few research papers published that are related to test methods to measure the pH of a concrete surface. Portland cement and many other hydraulic-cement-based concretes are highly alkaline materials. Depending on the actual chemistry of the portland cement and amount of alkalis present@ the pH of freshly placed concrete can vary from approximately 12 to over 13. The carbonation of concrete is known to lower the surface pH to a value in the vicinity of 9. The pH of a concrete surface plays an important role in the selection of flooring adhesive and placement of flooring materials@ especially with resilient flooring such as sheet vinyl. A concrete pH below 7.0 and above 10.0 is known to negatively affect resilient flooring@ its adhesive@ or both. The flooring installer is typically required to clean and prepare concrete slab surfaces prior to flooring installation. Pressure washing is not used to clean the concrete surface@ as the process will saturate the concrete surface with water and cause flooring failure due to excess slab moisture. Flooring installers often clean and scarify the concrete surface with sandpaper@ or shotblast the surface. The process of sanding or shot blasting can remove the carbonated surface layer of concrete and expose a concrete surface that has higher pH. When using the ASTM F710 test procedure (Appendix A)@ testing laboratories have reported concrete surface pH values as low as 6 or 7 because the test method is incorrect. In fact@ it essentially measures the pH of water and readily-soluble materials on the concrete surface versus the true pH of the concrete. Incorrect pH test results could lead to the selection and use of an incompatible adhesive for the flooring@ resulting in the risks of flooring failure. The concrete and flooring industries require a test method that measures the pH of concrete surface more accurately.

ACI 364.17T-2018相似标准


推荐

冬夏两季混凝土浇筑有什么区别?

特有的人工智能助手Roxi™, 通过发送智能通知和警报,消除人为错误,有效提高混凝土配比校准和强度测试结果的准确性。消除混凝土测试延迟完全嵌入在钢筋上,操作简单,易于在现场做出快速判断及决策,避免不必要的损失。提高数据准确性使用的成熟度方法已获得ASTM和ACI的认可,可作为现场测量混凝土强度的准确可靠测试方法。...

季节温度变化导致的混凝土开裂怎么破?

SmartRock2在混凝土浇筑之前装在混凝土模板或绑扎在钢筋上,每隔30分钟测量一次温度并记录在传感器内存中,使用智能手机上免费的app应用软件,可在智能手机上实时显示温度和强度。这些无线传感器提供更精确的读数和预估强度,完全符合成熟度有关的ASTM C1074 标准,以及ACI、CSA和DoT规范。结果证实比现场圆柱体破坏测试更精确。...

混凝土内部水分究竟是多少,你测得清吗?

此方法要求将测量探针放置到混凝土中确定的深度,并通过探针直接测量混凝土内部的含水量。与其他方法相比,原位RH测试具有许多优点:无论混合,骨料类型,楼板厚度或表面状况如何,现场测量探头都可直接测量混凝土内的实际水分情况。与氯化钙测试相比,原位测试更加节省测试时间和人工成本。原位探针可以根据国家标准进行校准。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号