GSO IEC 61223-3-2:2014

Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC 61223-3-2:2014 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC 61223-3-2:2014
发布
2014年
发布单位
GSO
当前最新
GSO IEC 61223-3-2:2014
 
 
适用范围
This part of IEC 61223 applies to the effectiveness of mammographic X-RAY EQUIPMENT, with respect to image quality and dose, in combination with aspects of EQUIPMENT safety. This standard applies to mammographic X-RAY EQUIPMENT and MAMMOGRAPHIC STEREOTACTIC DEVICES. The tests described in this standard require the quality and performance of the X-RAY IMAGE RECEPTORS to be assured prior to the acceptance testing when they are not an integral part of the mammographic X-RAY EQUIPMENT. This includes RADIOGRAPHIC FILMS, INTENSIFYING SCREENS, RADIOGRAPHIC CASSETTES, storage phosphor plates and ASSOCIATED EQUIPMENT such as film processors or storage phosphor plate readers, IMAGE DISPLAY DEVICES and HARD COPY CAMERAS. For testing RADIOGRAPHIC CASSETTES and INTENSIFYING SCREENS, this standard makes reference to ISO 4090. Sensitivity and contrast for the screen-film image receptors are considered to be stated according to ISO 9236-3. NOTE Currently there exists no IEC standard for acceptance testing of HARD COPY CAMERAS or IMAGE DISPLAY DEVICES. By the measurements described in this standard, data for AVERAGE GLANDULAR DOSE calculation can be determined. When the results of the ACCEPTANCE TEST are in compliance with the expected values, the baseline values for the subsequent CONSTANCY TESTS are established. This part of IEC 61223 defines a) the essential parameters which describe the performance of the above-mentioned mammographic X-RAY EQUIPMENT with regard to image quality and dose; and b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances. These methods mainly rely on non-invasive measurements that use appropriate test EQUIPMENT and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the ACCEPTANCE TEST. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance. This concept is described in 4.1. This standard does not in itself specify limiting values or tolerances for the parameters under investigation. A difficulty may arise with regard to the responsibility for acceptance testing when the film/screen combination, film processing chemistry or computed radiography system is changed. This arises from a combination of causes. Firstly, the image receptor MANUFACTURER and the X-RAY EQUIPMENT MANUFACTURER may be different. Secondly a change in image receptor or film processing chemistry may alter the system performance. When system integration such as the above occurs, it is important that acceptance testing is performed. When a change occurs which could alter system performance, it is essential that the system integrator (i.e. whoever is responsible for this change) discusses the implication of their change with the X-RAY EQUIPMENT MANUFACTURER so that the latter can adjust the imaging system if necessary. ACCEPTANCE TESTING of mammographic X-RAY EQUIPMENT requires average skill in medical physics. However, the decision concerning who performs the test is determined by local rules (e.g. contract, regulation, law).

GSO IEC 61223-3-2:2014相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号