CSA S136.1-1995(R2002)

Commentary on CSA Standard S136-94, Cold Formed Steel Structural Members


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA S136.1-1995(R2002) 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA S136.1-1995(R2002)
发布
1995年
发布单位
SCC
当前最新
CSA S136.1-1995(R2002)
 
 
代替标准
2002-09-18
被代替标准
S136.1-M1991
适用范围
1. Scope and Application 1.1 The Scope establishes that CSA Standard S136-94 applies to the design of cold formed steel structural members and that the design is based on limit states design (LSD) methods. Such members are roll or brake formed from carbon or low alloy flat-rolled steel products. Cold formed members find application where large surfaces are needed, as in deck and cladding, or where hot-rolled shapes are inappropriate or uneconomical. Cold formed steel structural members may be broadly divided into two categories as follows: (a) large-surface elements, eg, deck and cladding; and (b) individual structural sections, eg, channels, zees, and hats. Most of the experimental evidence supporting the provisions of the Standard has been obtained on specimens with material thicknesses between 0.4 and 6.5 mm, with some work on material up to 25 mm in thickness (1). With the exception of connections and columns, the requirements of the Standard may be deemed to apply to members of any thickness up to 25 mm. In the case of connections (see Clause 7 of the Standard), certain requirements such as the resistance of welds and fasteners in bearing are noted to apply only to a specific range of thickness. Where the requirements of the Standard are being applied in conjunction with, and supplementary to, the requirements of another design Standard (eg, S16.1), any upper limitation on thickness will be based on the requirements of the Standard that would normally govern. Although the requirements of the Standard are intended principally for applications in the design of buildings, the Standard may be used as a guide to the design of cold formed members in other structures, provided allowances are made for dynamic effects or other service conditions differing from those encountered in building structures. Cold formed components may also be combined with hot-rolled components in a single entity such as an open web steel joist having cold formed chords and hot-rolled web members. In this case, two aspects of the design require consideration, namely: the design of individual components within the joist and the overall design of the joist. If the Standard is used to design the cold formed column or beam-column (compression chord), then that component should be designed in complete accordance with Clause 6.6 or 6.7. With respect to the overall design, the requirements of another Standard could be used, provided the requirements are critically appraised to determine if they apply to cold formed, thin-walled members. For example, if another Standard that specifically covers steel joists contains simplification in design, such as neglect of joint eccentricities and neglect of transverse loads applied to a compressive member, where such simplifications are based on tests of non-cold formed, relatively thick-walled members only, these simplifications should not be applied to the design of cold formed, thin-walled compressive members without due consideration and justification. The Standard is thus intended not only to stand on its own but also to supplement other CSA Standard for the design of steel structural members. There are two fundamental concepts that distinguish the Standard from other structural steel design Standards. The first, the process of cold forming, induces selective strain hardening at corners that affects response to load in a manner quite different from the response of hot-rolled members, and the Standard allows this to be taken into account in Clause 5.2. Secondly, in contrast to individual structural sections whose prime function is to carry load, the structural strength of many cold formed members such as deck, cladding, and various members of a steel building system is only one of several desired functions. The optimum shape or profile is not necessarily the one that would be chosen on structural considerations alone and, in particular, the width-to-thickness ratio of flat elements may be well in excess of that which would be structurally economical. The Standard recognizes postbuckling s

CSA S136.1-1995(R2002)相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号