TEB 25-1985
数据显示 CRT 分辨率测量技术的调查

Survey of Data-Display CRT Resolution Measurement Techniques


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 TEB 25-1985 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
TEB 25-1985
发布
1985年
发布单位
ECIA - Electronic Components Industry Association
当前最新
TEB 25-1985
 
 
适用范围
"Introduction Information density in displays in increasing rapidly with the phenomenal growth of data and graphics displays. The introduction of color to data and avionics displays has required improvement of the shadow-mask CRT@ which heretofore had only limited resolution demands place on it@ mostly for television use. The color shadow-mask CRT requires special considerations when measuring resolution to avoid anomalies caused by the physical structure of the screen. All of this has renewed interest in display resolution and resolution measurement. The resolution of date displays and data-display cathode-ray tubes is a most difficult parameter to characterize accurately. Large difference in resolution measurements are often observed@ due to the diversity of display formats@ such as raster scan and stroke writing@ alphanumerics and graphics. The large diversity of measurement techniques also produces differing results. Differences in test operator perception and skills and to the problem. Resolution data should therefore be used with caution. Figure 1 shows some of the major sources of resolution measurement error. When comparing displays or CRTs@ the display engineer must be sure that resolution data are comparable. A display form manufacturer A specified as having 20-mil resolution at the half-amplitude points with 200-microampere beam current may actually have better resolution than a display from manufacturer B specified as having 10-mil spot size measured with the shrinking-raster technique at 100 microamperes. It's the age-old ""apples-and-oranges"" problem again. The resolution of CRT display may be expressed in any of several ways@ including: ? spot size ? line width ? number of TV lines ? modulation depth at a specified spatial frequency ? MTF curve Each of these measurements has differing connotations ad is not usually directly comparable to the others@ especially if drive or duty-cycle differences are considered. Resolution may be measured in an even greater number of ways@ as shown in Figure 2. It is the purpose of this paper to present information on as many techniques as possible."

TEB 25-1985相似标准


推荐

粘结力测试冲击摆CRT-VCP

具有文件破坏检测功能,确保数据完整性。增强摆式粘结强度试验仪功能。特点简介:自动安全防护制动装置,避免冲击试验后撞坏摆锤;增量式角度传感器和分辨率为0.1°数字显示器;36对盛样方盒和夹具,制备试样;高效安全系统,符合欧盟-机械指令2006/42/EC,运行可靠,操作舒适;内置RS 232端口(可通过计算机记录试验数据)相关图表:Vialit摆式粘结强度试验仪CRT-VCP软件界面...

Cooper CRT-TOT 德克萨斯路面抗裂性能测试仪

0.6~5.1 mm(0.025~0.2 inch)位移测量分辨率1μm(0.00004 inch)控制循环速率>1000Hz最大荷载25KN荷载精度0.25%循环周期5~1000s循环周期分辨率0.1%温控范围-5~40℃温制精度±0.5℃室内温度15~30℃测试终止条件0~100%荷载下降或0~10000次循环测试试件尺寸长度高度宽度150±2mm38~50±0.5mm76mm测试平板尺寸长度宽度高度...

浸水车辙仪CRT-WTIM

研发Windows软件软件可使用AASHTO-T324 和EN 12697-22两个规范,但测试完全是常规方法测试过程每个步骤均有指导说明提示操作者实时显示当前水温,试样温度和车辙深度数据按一定间隔记录到磁盘用作以后分析软件通过USB接口与浸水车辙仪通讯还有传感器检查、诊断和校正程序Excel格式数据输出附件:主机报价不包含附件,用户可根据需要选购。...

液压沥青旋转压实仪CRT-GYR-H

压实通过端板对放置于100mm或150mm内径模具内已知质量沥青混合料施加垂直应力(通常为600kPa),上下端板保持平行、水平,模具纵轴与垂直方向以一固定角度旋转。压实过程中,试样高度自动测量,混合料密度和空隙率实时计算。压实过程中,测试数据以图形和数据格式在屏幕上显示,并以Excel兼容格式存储。操作者可以选择压实到指定旋转次数或压实到指定混合料密度或空隙率。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号