BS EN ISO 11929-1:2021
确定电离辐射测量的特征限值(判定阈值、检测限值和覆盖间隔限值) 基础知识和应用 基本应用

Determination of the characteristic limits (decision threshold, detection limit and limits of the coverage interval) for measurements of ionizing radiation. Fundamentals and application - Elementary applications


标准号
BS EN ISO 11929-1:2021
发布
2021年
发布单位
英国标准学会
当前最新
BS EN ISO 11929-1:2021
 
 
适用范围
1   Scope The ISO 11929 series specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the “ decision threshold ”, the “ detection limit ” and the “ limits of the coverage interval ” for a non-negative ionizing radiation measurand when counting measurements with preselection of time or counts are carried out. The measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, the measurand can be the net count rate as the difference of the gross count rate and the background count rate, or the net activity of a sample. It can also be influenced by calibration of the measuring system, by sample treatment and by other factors. ISO 11929 has been divided into four parts covering elementary applications in this document, advanced applications on the basis of the ISO/IEC Guide 3‑1 in ISO 11929‑2, applications to unfolding methods in ISO 11929‑3, and guidance to the application in ISO 11929‑4. This document covers basic applications of counting measurements frequently used in the field of ionizing radiation metrology. It is restricted to applications for which the uncertainties can be evaluated on the basis of the ISO/IEC Guide 98‑3 (JCGM 2008). In Annex A, the special case of repeated counting measurements with random influences is covered, while measurements with linear analogous ratemeters are covered in Annex B. ISO 11929‑2 extends the former ISO 1192...

BS EN ISO 11929-1:2021相似标准


推荐

GB/T 25915洁净室空气洁净度等级新国标发布,明年3月1日实施!

C.2 大于5μm粒子(大粒子)———M 描述符 C.2.1 应用 如果要评定大于5μm 粒子造成污染风险,宜采用适合于这类粒子具体特性采样装置测量程序。 阈值粒径分布在5μm~20μm 悬浮粒子浓度测量,可在三种规定状态(空态、静态动态)下进行。 空气悬浮粒子总体中大粒子主要是工艺环境中释放出粒子。宜根据具体应用情况来确定适用采样装置测量程序。...

动态校准、动态测试与动态测量辨析

计量是实现单位统一、保障量值准确可靠活动。计量学是关于测量及其应用科学,它涵盖测量理论实践各个方面,而不论测量确定度如何,也不论 测量是在哪个领域中进行。 2动态问题2. 1 基本概念关于动态几个概念,可以从上述定义中抽象推衍出。关于动态测量,俄国学者有两种定义:一种认为“动态测量是在物理量变化过程中对其进行测量”。...

乘用车内空气质量强制标准:8种有害物质将被严控

据编制组介绍,经过多次专家讨论,确定了制定车内空气控制物质3条基本原则:能够在车内空气中检测到;对人体健康影响较大,尤其应严格控制致癌性物质;确认是由车辆内饰件挥发出来物质。  ...

乘用车内空气质量强制标准拟出台

据编制组介绍,经过多次专家讨论,确定了制定车内空气控制物质3条基本原则:能够在车内空气中检测到;对人体健康影响较大,尤其应严格控制致癌性物质;确认是由车辆内饰件挥发出来物质。  ...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号