EN 61757-2-2:2017

Fibre optic sensors - Part 2-2: Temperature measurement - Distributed sensing


说明:

  • 此图仅显示与当前标准最近的5级引用;
  • 鼠标放置在图上可以看到标题编号;
  • 此图可以通过鼠标滚轮放大或者缩小;
  • 表示标准的节点,可以拖动;
  • 绿色表示标准:EN 61757-2-2:2017 , 绿色、红色表示本平台存在此标准,您可以下载或者购买,灰色表示平台不存在此标准;
  • 箭头终点方向的标准引用了起点方向的标准。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 EN 61757-2-2:2017 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
EN 61757-2-2:2017
发布
2017年
发布单位
欧洲电工标准化委员会
当前最新
EN 61757-2-2:2017
 
 
适用范围
IEC 61757-2-2:2016(E) defines detail specifications for distributed temperature measurement by a fibre optic sensor, also known as fibre optic distributed temperature sensing (DTS). DTS includes the use of Raman scattering, Brillouin scattering and Rayleigh scattering effects. In addition, Raman scattering and Rayleigh scattering based measurements are performed with a single-ended fibre configuration only. Brillouin scattering based measurements are performed with a single-ended fibre or fibre loop configuration. The technique accessible from both sides at same time (e. g. Brillouin optical time domain analysis, BOTDA) is referred to here as a loop configuration. Generic specifications for fibre optic sensors are defined in IEC 61757-1:2012. This part of IEC 61757 specifies the most important DTS performance parameters and defines the procedures for their determination. In addition to the group of performance parameters, a list of additional parameters has been defined to support the definition of the measurement specifications and their associated test procedures. The definitions of these additional parameters are provided for informational purposes and should be included with the sets of performance parameters. A general test setup is defined in which all parameters can be gathered through a set of tests. The specific tests are described within the clause for each measurement parameter. This general test setup is depicted and described in Clause 4 along with a list of general information that should be documented based upon the specific DTS instrument and test setup used to measure these parameters as per IEC 61757-2-2. Annex A provides a blank performance parameter table which should be used to record the performance parameter values for a given DTS instrument and chosen optical test setup configuration. Annex B provides guidelines for optional determination of point defect effects. Keywords: fibre optic distributed temperature sensing (DTS) This publication is to be read in conjunction with IEC 61757-1:2012

EN 61757-2-2:2017相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号