CAN/CSA-C22.2 No.80601-2-67-2017

Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential performance of oxygen conserving equipment


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CAN/CSA-C22.2 No.80601-2-67-2017 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CAN/CSA-C22.2 No.80601-2-67-2017
发布
2017年
发布单位
SCC
当前最新
CAN/CSA-C22.2 No.80601-2-67-2017
 
 
代替标准
CSA C22.2 No. 80601-2-67:23
被代替标准
CAN/CSA-Z18779-08 (R2013)
适用范围
IEC 60601-1:2005+A1:2012, 1.1 is replaced by: This particular standard is applicable to the BASIC SAFETY and ESSENTIAL PERFORMANCE of oxygen CONSERVING EQUIPMENT, hereafter referred to as ME EQUIPMENT, in combination with its ACCESSORIES intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the PATIENT'S inspiratory cycle, when used in the HOME HEALTHCARE ENVIRONMENT. Oxygen CONSERVING EQUIPMENT is typically used by a LAY OPERATOR. NOTE 1 CONSERVING EQUIPMENT can also be used in professional health care facilities. NOTE 2 CONSERVING EQUIPMENT can be used with an oxygen concentrator. This particular standard is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to CONSERVING EQUIPMENT, where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the CONSERVING EQUIPMENT. This particular standard is only applicable to active devices (e.g. pneumatically or electrically powered) and is not applicable to non-active devices (e.g. reservoir cannulas). NOTE 3 CONSERVING EQUIPMENT complying with this particular standard can be incorporated with other devices that have their own standards, in which case the combination needs to comply with both standards. EXAMPLES CONSERVING EQUIPMENT combined with a pressure regulator [2], an oxygen concentrator [1] or liquid oxygen equipment [6]. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE 4 See also 4.2 of the general standard. This particular standard is a particular standard in the IEC 60601 series of standards.

CAN/CSA-C22.2 No.80601-2-67-2017相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号