IEC 60695-2-11:2014 RLV

Fire hazard testing — Part 2-11: Glowing/hot-wire based test methods — Glow-wire flammability test method for end-products (GWEPT)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 60695-2-11:2014 RLV 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
IEC 60695-2-11:2014 RLV
发布
2014年
发布单位
澳大利亚标准协会
替代标准
IEC 60695-2-11:2021 RLV
当前最新
IEC 60695-2-11:2021 RLV
 
 
适用范围
IEC 60695-2-11:2014 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60695-2-11:2014 specifies a test method on an end product. It is intended to simulate the effects of thermal stresses produced by an electrically heated source to represent a fire hazard. This test method is used to check that, under defined test conditions, an end product exposed to an electrically heated source has either a limited ability to ignite or, if it ignites, a limited ability to propagate flame. However, the fire hazard analysis, the flammability aspects and the flame spreading to other products are not covered by the present standard. This second edition of IEC 60695-2-11 cancels and replaces the first edition of IEC 60695-2-11 published in 2000. It constitutes a technical revision. The main changes with respect to the previous edition are:
- the Introduction has been added to provide background and how it relates to the Scope,
- the Scope has been modified for greater clarity and reference to basic safety publications,
- numerous terms and definitions relevant to this Standard have been added to Clause 3,
- the application of "small parts" and "insignificant mass" have been introduced and clarified,
- the different types of specimens, how to specify them, and limitations of the test method have been further clarified in Clause 4,
- clarified in Clause 5 the distance to specified layer when unknown,
- the information from Clause 6 has been moved into the test procedure in Clause 8,
- the conditioning of the specified layer and the laboratory ambient test conditions were clarified in Clause 7,
- measurement of the maximum flame height was removed from Clause 9,
- the reference to this test as "GWEPT" was introduced along with an applicable title change and
- Annex A has been revised to reflect current practice by prominent product committees.
This publication is to be read in conjunction with IEC 60695-2-10:2013.