ASHRAE 90441-2008
高密度数据中心案例研究和最佳实践

High Density Data Centers Case Studies and Best Practices


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASHRAE 90441-2008 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
ASHRAE 90441-2008
发布
2008年
发布单位
ASHRAE - American Society of Heating@ Refrigerating and Air-Conditioning Engineers@ Inc.
当前最新
ASHRAE 90441-2008
 
 
适用范围
Introduction Data centers and telecommunications rooms that house datacom equipment are becoming increasingly more difficult to adequately cool. This is a result of IT manufacturers increasing datacom performance year after year at the cost of increased heat dissipation. Even though performance has@ in general@ increased at a more rapid rate than power@ the power required and the resulting heat dissipated by the datacom equipment has increased to a level that is putting a strain on data centers. However@ in the struggle to improve the thermal management characteristics of data centers it is sometimes important to assess today's data center designs. The objective of this book is to provide a series of case studies of high density data centers and a range of ventilation schemes that demonstrate how loads can be cooled using a number of different approaches. This introductory chapter describes the various ventilation designs most often employed within data centers. This book does not present an exhaustive resource for existing ventilation schemes but@ rather@ a wide variety of schemes commonly used in the industry. Seven primary ventilation schemes are outlined here. In the case studies that follow@ each of these will be shown with detailed measurements of airflow@ power@ and temperature. The most common ventilation design for data centers is the raised-access floor supply@ with racks arranged in a cold-aisle/hot-aisle layout (see Figure 1.1). The chilled-air supply enters the room through perforated tiles in the raised floor@ washing the fronts of the racks facing the cold aisle. The hot exhaust air from the racks then migrates back to the inlet of the computer room air-conditioning units (CRACs) typically located on the perimeter of the data center. Another version of the raised-access floor supply is shown in Figure 1.2@ where the air-handling units (AHUs) are located beneath the floor containing the IT equipment. One of the key advantages of this arrangement is that all the mechanical equipment is located in a room separate from the IT equipment@ which allows for ease of maintenance.

ASHRAE 90441-2008相似标准


推荐





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号