CSA/ANSI Z83.26:20 • CSA 2.37-2020

Gas-fired outdoor infrared patio heaters


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA/ANSI Z83.26:20 • CSA 2.37-2020 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA/ANSI Z83.26:20 • CSA 2.37-2020
发布
2020年
发布单位
SCC
当前最新
CSA/ANSI Z83.26:20 • CSA 2.37-2020
 
 
代替标准
97.100.20
被代替标准
ANSI Z83.26-2014 • CSA 2.37-2014
适用范围
1 Scope 1.1 This Standard applies to newly produced gas-fired outdoor infrared patio heaters (see Clause 3) hereinafter referred to as “heaters” or “appliances”, constructed entirely of new, unused parts and materials for use with: a) natural gas; or b) propane. 1.2 The heaters covered by this Standard are intended for installation in and heating of residential or nonresidential spaces. 1.3 Infrared patio heaters may be suspended overhead, angle-mounted overhead, wall-mounted, floormounted or for tabletop use. 1.4 Patio heaters intended for tabletop use are those limited to input ratings of 24 000 Btu/hr (7034 W) or less. These units incorporate an integral self-contained propane gas supply system consisting of a maximum of two disposable 1 lb (0.45 kg) fuel capacity cylinders and operating at pressures not greater than 5 psi (34.5 kPa). 1.5 Infrared patio heaters not intended for tabletop use may be for connection to a) a fixed fuel piping system operating at inlet gas pressures not exceeding 1/2 psi (3.5kPa); or b) an integral self-contained propane gas supply system, provided the appliance incorporates mounting means for the attachment of a maximum of one cylinder limited to a maximum of 20 lb (9.1 kg) of fuel operating at regulated outlet with i) pressure not exceeding 11 in wc (2.74 kPa); or ii) pressures in excess of 11 in wc (2.74 kPa) but not greater than 5 psi (34.5 kPa). 1.6 Clause 2 contains a list of standards specifically referenced in this Standard and sources from which these reference standards may be obtained. 1.7 Special construction provisions applicable to an appliance designed for use with an optional listed conversion kit are outlined under Annex D. 1.8 Special construction provisions applicable to infrared heaters designed to operate at altitudes over 2000 ft (610 m) are outlined in Annex E. 1.9 If a value for measurement as given in this Standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification. This Standard contains SI (Metric) equivalents to the yard/pound quantities, the purpose being to allow the standard to be used in SI (Metric) units. (IEEE/ASTM-SI-10 is used as a guide in making metric conversion from yard/pound quantities.) If a value is given for a measurement and an equivalent value in other units, the first stated is to be regarded as the requirement. The given equivalent value may be approximate. If a value for a measurement and an equivalent value in other units are both specified as a quoted marking requirement, the first stated unit, or both shall be provided. 1.10 In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

CSA/ANSI Z83.26:20 • CSA 2.37-2020相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号