FprEN ISO 29461-3
旋转机械的空气过滤器进气系统 测试方法 第3部分:过滤器元件的机械完整性 (ISO/FDIS 29461-3:2024)

Air filter intake systems for rotary machinery - Test methods - Part 3: Mechanical integrity of filter elements (ISO/FDIS 29461-3:2024)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 FprEN ISO 29461-3 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
FprEN ISO 29461-3
发布单位
欧洲标准化委员会
 
 
适用范围
8. Scope The ISO 29461 series specifies methods and procedures to determine the performance of particulate air filters used in air intake filter systems for rotary machinery such as gas turbines, compressors and other internal combustion engines. The ISO 29461-3 of the standard specifies a method and procedure to test the mechanical integrity (“Burst Test”) of individual filter elements up to an abnormal final test pressure drop of maximum 6250 Pa. Any other customer defined final pressure drop up to a maximum of 8000 Pa shall be reported as variation from the standard. It is within the liability of the user to define the maximum possible value (lower or higher) for a certain application and to define the burst strength requirements for this test procedure. As the pressure drops under typical operating conditions are on a much lower level, it is not intended to specify a final pressure drop for any application within this procedure. This procedure is intended for all types of filter elements (e.g. V-bank cassette filters or filter cartridges) used in the final stage(s) of an Air Intake Filter Systems for Rotary Machinery in various environmental conditions, as e.g. in marine applications. These filters are operating at flow rates within the range of 0,25 m³/s (900 m³/h) up to 2,23 m³/s (8000 m³/h), no matter if it is used in a static or pulse cleaned air intake system.

FprEN ISO 29461-3相似标准


推荐

空气过滤器国际标准ISO16890

4部分:确定最小部分试验效率调节方法   ISO 29464,空气和其他气体清洗设备术语   ISO 29463,高效过滤器和过滤介质去除空气颗粒   ANSI/ASHRAE 52.2-2007,般通风空气净化装置按粒度去除效率测试方法   EN 779,颗粒空气过滤器对一般通风过滤性能测定   参考书目   [1]ISO29461,旋转机械过滤系统。试验方法。...

CSI 臭氧老化试验箱说明(二)

3)试验箱温度传感器:又称“干球”传感器,为铂(Pt-100)RTD(电阻式温度检测器),安装在试验箱内。用于监测试验箱内空气温度。 (4)排气管道:调节风门部分或完全打开时,试验箱空气通过该管道排出。该空气通常温暖潮湿,应输送到不与该排气管道物理实体连接设施排气系统内。 (5)风道:调节风门部分或完全打开时,环境空气通过进气口空气过滤器和该管道吸入。 ...

氙灯老化试验箱用途

3)试验箱温度传感器:又称“干球”传感器,为铂(Pt-100)RTD(电阻式温度检测器),安装在试验箱内。用于监测试验箱内空气温度。(4)排气管道:调节风门部分或完全打开时,试验箱空气通过该管道排出。该空气通常温暖潮湿,应输送到不与该排气管道物理实体连接设施排气系统内。(5)风道:调节风门部分或完全打开时,环境空气通过进气口空气过滤器和该管道吸入。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号