GSO ISO 80601-2-69:2016

Medical electrical equipment -- Part 2-69: Particular requirements for basic safety and essential performance of oxygen concentrator equipment


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO ISO 80601-2-69:2016 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO ISO 80601-2-69:2016
发布
2016年
发布单位
GSO
当前最新
GSO ISO 80601-2-69:2016
 
 
适用范围
IEC 60601-1:2005+Amendment 1:2012, 1.1 is replaced by: This particular standard specifies requirements for the BASIC SAFETY and ESSENTIAL PERFORMANCE of an OXYGEN CONCENTRATOR in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT, intended to increase the oxygen concentration of gas intended to be delivered to a single PATIENT. Such OXYGEN CONCENTRATORS are typically intended for use in the HOME HEALTHCARE ENVIRONMENT, including TRANSIT OPERABLE use by a single PATIENT in various environments including any private and public transportation as well as in commercial aircraft. NOTE 1 Such an OXYGEN CONCENTRATOR can also be used in professional health care facilities. This particular standard is applicable to a TRANSIT‐OPERABLE and non‐TRANSIT‐OPERABLE OXYGEN CONCENTRATOR. This particular standard is applicable to an OXYGEN CONCENTRATOR integrated into or used with other medical devices, ME EQUIPMENT or ME SYSTEMS. EXAMPLE 1 An OXYGEN CONCENTRATOR with integrated oxygen CONSERVING EQUIPMENT [10] or humidifier [4]. EXAMPLE 2 An OXYGEN CONCENTRATOR used with a flowmeter stand. EXAMPLE 3 An OXYGEN CONCENTRATOR as part of an anaesthetic system for use in areas with limited logistical supplies of electricity and anaesthetic gases. [3] EXAMPLE 4 An OXYGEN CONCENTRATOR with an integrated liquid reservoir or gas cylinder filling system. This particular standard is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to an OXYGEN CONCENTRATOR, where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the OXYGEN CONCENTRATOR. This particular standard does not specify the requirements for OXYGEN CONCENTRATORS for use with a MEDICAL GAS PIPELINE SYSTEM which are given in ISO 10083. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE 2 See also 4.2 of the General Standard. This International Standard is a particular standard in the IEC 60601‐1 series of standards.

GSO ISO 80601-2-69:2016相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号