CSA C22.2 No.263-2015

Fire pump controllers


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA C22.2 No.263-2015 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA C22.2 No.263-2015
发布
2015年
发布单位
SCC
当前最新
CSA C22.2 No.263-2015
 
 
代替标准
13.220.10
被代替标准
C22.2 NO. 263-09 R2014
适用范围
1.1 Products covered 1.1.1 These requirements cover controllers intended for starting and stopping centrifugal and positive displacement fire pumps, including automatic and non-automatic types for electric motor with or without transfer switch or engine driven pumps in accordance with Annex A, item 1. Types of controllers covered include diesel engine, electric motor, limited service, medium voltage and residential. Controllers may be suitable for use as service equipment. This equipment is for installation in non-hazardous locations in accordance with Annex A, item 2. 1.1.2 Controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage or wound rotor motors rated 600 V or less. Controllers for squirrel cage motors may be for across-the-line or reduced inrush current starting. Controllers may be provided with integral automatic transfer switches. 1.1.3 Variable speed fire pump controllers for electric motor driven, centrifugal fire pumps are intended for use with squirrel cage induction, inverter duty rated motors rated 600 V or less, and rated for 50 Hz or 60 Hz. 1.1.4 Limited service controllers are intended for across-the-line starting of squirrel cage motors rated 22 kW (30 hp) or less, 600 V or less. Controllers may be provided with integral automatic transfer switches. 1.1.5 Medium voltage fire pump controllers are intended for use with squirrel cage motors rated 601 V – 7.2 kV AC. 1.1.6 Residential fire pump controllers are intended for use with single-phase squirrel cage motors rated 240 V or less. Residential fire pump controllers are intended to be used in one or two family dwelling units in accordance with the requirements of item 35 in Annex A. 1.1.7 Diesel engine fire pump controllers rated nominal 24 V DC or less are intended for use with fire pump engines. Where required, AC voltage is limited to 600 V AC or less. 1.2 Products not covered 1.2.1 An automatic transfer switch intended to be used in fire pump circuits, that is provided separate from a controller. Note: Stand-alone automatic transfer switches for fire pump circuits are covered by the requirements of item 11, Annex A.

CSA C22.2 No.263-2015相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号