1. SCOPE 1.1 This method of test for flammability characteristics is applicable to certain low
density insulating materials that do not melt or drip during exposure to fire (see Appendix A). It
is used in establishing the Flame Spread Classification for those foamed plastics whose
flammability assessment by CAN/ULC-S102 requires the use of the rate formula FSV = 92.5 d/t
but where the necessary parameters ('d' & 't') for use in the formula are difficult to define.
Note: In the formula FSV = 92.5 d/t, 't' is the time in minutes for the flame front to propagate a distance
of 'd' metres where there is a marked reduction in the advance of the flame front during the
CAN/ULC-S102 test. 1.2 The purpose of this test is to determine the comparative burning characteristics of
the material under test by exposing the material in a corner wall configuration to a test fire. 1.3 It is the intent of this method to register performance during the period of
exposure and not to determine suitability for use after the test exposure.