CSA A440.3-1993

User Guide to CSA Standard A440.2-93, Energy Performance Evaluation of Windows and Sliding Doors


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 CSA A440.3-1993 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
CSA A440.3-1993
发布
1993年
发布单位
SCC
替代标准
CSA A440.3-1998
当前最新
CSA A440.3-1998
 
 
被代替标准
A440.3-M1991
适用范围
1.1 The angle from horizontal at which windows are installed has some effect on thermal properties. The Standard specifies the determination of reference values for vertical installation, as most windows are installed at this angle. These values of F and U are generally appropriate for comparing the performance of windows installed at other angles. The ER value, however, is based on solar radiation incident on vertical surfaces and therefore does not apply directly to windows installed at other angles. 1.3 The energy rating in the Standard is not currently relevant for energy use required for mechanical cooling of residences. The effect of windows on energy requirements for cooling of a residence can be calculated, but a simple comparative rating procedure has not yet been standardized. Similarly, the energy rating is not directly applicable to heating or cooling applications in multistorey apartments or commercial building applications, where the relationship of heating and cooling loads to weather conditions is more complex. In developing the energy rating, each of the weather factors in 13 Canadian cities with more than 4000 heating degree-days were averaged, including solar radiation incident on windows facing the four cardinal compass directions, to produce a single set of average weather conditions. Rating values based on these average conditions therefore do not apply to any specific location. The ranking of the windows, however, is the same, for the most part, as that which would be obtained using local weather conditions. The ranking of windows would, however, likely be affected if an ER value were computed for a specific orientation. A method for obtaining ERS values for a specific location and orientation is provided in Part 2 of this User Guide, for those who may wish to select or market windows on this basis. The ERS values so obtained can be used to make a comparative estimate of the effect on annual heating energy requirements of alternate window installations, and the User Guide provides a method for making such estimates. See Clause 8 of this User Guide regarding the effect of window size on Er values. 1.5 Thermal properties of windows may change with time. For example, there may be some uncertainty about the long-term service life of some sealed glazing systems. Similarly, air leakage rates for some air-sealing systems change more rapidly than others. Standard methods for establishing the ability of windows to retain certain thermal properties have not been established.

CSA A440.3-1993相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号