UL 1256-2002
UL 屋顶平台结构安全防火测试标准(第四版;2007年1月12日(含 1 月 12 日)修订重印)

UL Standard for Safety Fire Test of Roof Deck Constructions (Fourth Edition; Reprint with Revisions Through and Including January 12@ 2007)

2006-11

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL 1256-2002 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
UL 1256-2002
发布
2002年
发布单位
美国保险商实验所
替代标准
UL 1256 BULLETIN-2006
当前最新
UL 1256 BULLETIN-2018
 
 
适用范围
These requirements cover fire test methods to evaluate the performance of metallic and nonmetallic roof deck constructions subjected to internal (under deck) fire exposures for the purpose of determining the contribution of the roof covering material@ insulation@ and other components of the roofing system to the spread of fire within a building. As the extent of flame propagation@ thermal degradation@ and combustive damage are determined after roof deck constructions are exposed to controlled fire conditions@ these requirements are not intended for use in describing or defining the fire hazard or risk of fire under actual fire conditions. These requirements do not include tests to evaluate other potential hazards to roof deck constructions@ such as structural integrity under fire exposure or wind uplift. Two fire test methods are described in Parts I and II of this Standard. One of these test methods shall be selected based on assessment of fire test experience@ as outlined in 1.4@ 1.5 and 1.6. Part I describes the large scale fire test method used to evaluate roof deck constructions which by experience in actual installations were known to have contributed extensively to underdeck fire spread or@ conversely@ were regarded as being eligible for classification from this standpoint. Part II describes the small scale fire test method whereby the Steiner fire test chamber is used to evaluate roof deck constructions for resistance to underdeck fire spread. The conditions of acceptance under this test method were established by analysis of correlative data developed on a specific construction which exhibited adequate performance in the large scale fire test method described in Part I. This construction consisted of a steel roof deck@ without vapor retarder or adhesives@ insulated with one inch thick plain vegetable fiberboard roof insulation mechanically attached and covered with a three ply bitumen built-up roof covering with gravel surface. For roof deck constructions dissimilar to any constructions previously evaluated under Part I@ the large scale fire test method is to be conducted.

UL 1256-2002相似标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号