EN IEC 61869-10:2018
互感器 第10部分:低功率无源电流互感器的附加要求

Instrument transformers - Part 10: Additional requirements for low-power passive current transformers


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 EN IEC 61869-10:2018 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
EN IEC 61869-10:2018
发布
2018年
发布单位
CENELEC - European Committee for Electrotechnical Standardization
当前最新
EN IEC 61869-10:2018
 
 
适用范围
This part of IEC 61869 is a product standard and covers only additional requirements for lowpower passive current transformers. The product standard for low-power passive current transformers comprises IEC 61869-1@ together with IEC 61869-6 and this document with specific requirements. This document is applicable to newly manufactured low-power passive current transformers with analogue output for use with electrical measuring instruments or electrical protective devices having a rated frequency from 15 Hz to 100 Hz. This document covers low-power passive current transformers used for measurement or protection and multi-purpose low-power passive current transformers used for both measurement and protection. Subclause 5.6.1001 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical measuring instruments. Subclause 5.6.1002 covers the accuracy requirements that are necessary for low-power passive current transformers for use with electrical protective relays@ and particularly for forms of protection in which the prime requirement is to maintain the accuracy up to several times the rated current. If required@ the transient accuracy of low-power passive current transformers during fault is also given in 5.6.1002. Low-power passive current transformers have analogue voltage output only (for digital output or for technology using any kind of active electronic components refer to IEC 61869-82). Such low-power passive current transformers can include the secondary signal cable (transmitting cable). The principle of operation of derivative low-power passive current transformers using air-core coils (Rogowski coils) is given in Annex 10B and the principle of operation of proportional low-power passive current transformers using iron-core coils with integrated shunt is given in Annex 10C.

EN IEC 61869-10:2018相似标准


推荐

电能计量中电流感应技术分析

电流互感器可以测量非常大电流,消耗功率却很少,但由于是磁化电流,它一般相应会有一个很小相移(0.1°~0.3°)。如果没有校正,功率因素下会产生相当大误差。此外,铁芯使用 铁氧体材料在大电流下会饱和,而且磁化后铁芯还会产生磁滞现象,除非重新去磁,否则精度就会下降。  当电流涌动超出互感器额定电流,或者在电路中实际有直流元件(如驱动一个大半波整流负载)时,互感器将会产生饱和现象。...

40个电气问答汇总,电气工程师应该掌握

电流作用时,电压短路,电压作用时,电流开路。(4)叠加原理只适用于对电压和电流叠加,而功率不能用叠加原理来计算。33、水轮发电机为什么要设置过电压保护?由于水轮机调速系统调节缓慢,在事故甩负荷后,容易出现不饮许过电压,所以规定要设置过电压保护。34、什么叫发电机励及发电机失磁?励是表示发电机励磁电流低于静稳定极限所对应励磁电流。失磁是指发电机失去励磁电流。...

【宇创屹鑫压力变送器冠名】225项行业标准报批公示 多项与仪器仪表相关

9 JB/T 14253-2022直流电能表检验用功率技术规范本文件规定了直流电能表检验用功率分类、推荐电量、通用要求、技术要求、试验、检验规则及包装和贮存等。本文件适用于直流电压上限为1000V直流电能表检验用功率制造。10 JB/T 20202-2022澄清度测定仪本文件规定了澄清度测定仪型号、要求、试验方法、检验规则、标志、使用说明书、包装、运输和贮存。...

555项行业标准批准发布 多项与仪器仪表相关

2022-10-019 JB/T 14253-2022直流电能表检验用功率技术规范本文件规定了直流电能表检验用功率分类、推荐电量、通用要求、技术要求、试验、检验规则及包装和贮存等。本文件适用于直流电压上限为1000V直流电能表检验用功率制造。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号