GSO OIML R100-1:2016
测量金属污染物的原子吸收光谱仪系统 第1部分:计量和技术要求

Atomic absorption spectrometer systems for measuring metal pollutants – Part 1: Metrological and technical requirements


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO OIML R100-1:2016 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO OIML R100-1:2016
发布
2016年
发布单位
GSO
当前最新
GSO OIML R100-1:2016
 
 
适用范围
1.1 This Recommendation provides requirements for defining, testing and verifying the performance of atomic absorption spectrometer (AAS) systems when used for measuring metal pollutants in water as mandated by national laws and regulations. It does not intend to exclude any other equivalent means of measuring metal pollutants in water. An AAS system can be applied simply and rapidly for the determination of a variety of metals in potable, ground, surface and saline waters as well as domestic and industrial wastewaters. An AAS system of this type may be applied for the determination of metal concentrations in other matrices such as soil, etc. References [1] – [4] give a description of the AAS system and some applications. 1.2 The flame and electrothermal atomization (furnace) types of AAS atomizers are covered by this Recommendation. The hydride generation and the cold vapor techniques are also briefly described. The conditions of operation described for each system type are intended to cover applications for trace analysis. 1.3 It is possible that the performance of an instrument can exceed the minimum criteria prescribed in this Recommendation for these applications. Higher accuracy and repeatability of measurements can be accomplished by careful attention to the optimization of the performance of each of the instrument’s components. In such cases, success may also depend on the knowledge, skill, and experience of the analyst, as well as the quality of instrument manufacture. 1.4 A sample usually needs to undergo a specific preparation technique prior to analysis with an AAS system. Sampling techniques, methods of analysis and impact of interfering components are beyond the scope of this Recommendation. As appropriate, the relevant international, regional or national sampling techniques and reference methods of analysis should be applied. 1.5 This Recommendation does not address requirements and tests that may be necessary for operator safety. Therefore, users should determine whether an instrument meets the safety and labeling requirements specified in national regulations.

GSO OIML R100-1:2016相似标准


推荐

浅谈原子吸收光谱ICP光谱

二、原子吸收光谱法基本原理从光源发射出具有待测元素特征谱线光,通过试样蒸气时,被蒸气中待测元素基态原子吸收吸收程度与被测元素含量成正比。所以,可以根据测得吸光度求得试样中被测元素含量。三、原子吸收光谱仪基本构造原子吸收分光光度计分为单光束型双光束型。其结构可分为五个部分:光源、原子化器、光学系统、检测系统与数据处理系统。...

原子吸收光谱ICP光谱比较

二、原子吸收光谱法基本原理从光源发射出具有待测元素特征谱线光,通过试样蒸气时,被蒸气中待测元素基态原子吸收吸收程度与被测元素含量成正比。所以,可以根据测得吸光度求得试样中被测元素含量。三、原子吸收光谱仪基本构造原子吸收分光光度计分为单光束型双光束型。其结构可分为五个部分:光源、原子化器、光学系统、检测系统与数据处理系统。...

X射线荧光光谱技术在重金属检测中应用

或者说每个谱系特征X射线能量平方根与原子序数成线性关系。因此只要用仪器准确测出特征X射线能量即可定性分析被测介质中元素种类。X射线荧光光谱技术系统组成    X射线光谱仪除样品室外,主要由激发探测系统组成。X射线发生部分有X射线管、高压变压器、冷却装置、控制系统。分光系统有分光室真空系统单色仪。测量系统有检测器、前置放大器、高压板、通道板、控制系统。计算数据处理系统。...

《锌及锌合金钴含量测定萃取分离-火焰原子吸收光谱法》

仪器:   1.一般要求   所有玻璃量器皿应符合 GB/T 12805-2015、GB/T 12806—2011 或 GB/T 12808-2015 规定 A 级。   2.火焰原子吸收光谱仪   火焰原子吸收光谱仪,配备钴空心阴极灯,备有空气-乙炔燃烧器,附带数据读取系统背景校正装置。空气-乙炔气体应纯净,能提供清澈稳定贫燃火焰。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号