GSO IEC 62772:2021
交流电压大于 1 000 V 和直流电压大于 1 500 V 变电站用复合空心站支柱绝缘子 定义、试验方法和验收标准

Composite hollow core station post insulators for substations with a.c. voltage greater than 1 000 V and d.c. voltage greater than 1 500 V - Definitions, test methods and acceptance criteria


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC 62772:2021 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC 62772:2021
发布
2021年
发布单位
GSO
当前最新
GSO IEC 62772:2021
 
 
适用范围
IEC 62772:2016 applies to composite hollow core station post insulators consisting of a load-bearing insulating tube (core) made of resin impregnated fibres an insulating filler material (e.g. solid, liquid, foam, gaseous pressurized or unpressurized), a housing (outside the insulating tube) made of polymeric material (for example silicone or ethylene-propylene) and metal fixing devices at the ends of the insulating tube. Composite hollow core station post insulators as defined in this standard are intended for general use in substations in both, outdoor and indoor environments, operating with a rated AC voltage greater than 1 000 V and a frequency not greater than 100 Hz or for use in direct current systems with a rated voltage greater than 1 500 V. The object of this standard is: - to define the terms used; - to prescribe test methods; - to prescribe acceptance criteria. All the tests in this standard, apart from the thermal-mechanical test, are performed at normal ambient temperature. This standard does not prescribe tests that may be characteristic of the apparatus of which the composite hollow core station post insulator ultimately may form a part.

GSO IEC 62772:2021相似标准


推荐

高压开关的绝缘预防性试验项目及标准

对此,GB763-90《交流高压电器在长期工作时的发热》、DL405-91《进口220~500kV高压开关隔离开关技术规范》等标准均已明确规定:测试采用直流电压降法,通入的电流不得小于100A。所以电桥法直流电压降法的测量结果是有差别的,而直流压降法更能反映断路器的实际工作状况。...

湖南发布先进制造业关键配套产品工程化攻关清单

67直流融冰装置电力装备1、额定电流12000A,额定电压25kV.2、占地面积1000平方米。3.融冰谐波≤5%,可抑制同塔双回线路感应电压6810kV防雷防冰复合绝缘子电力装备1、整支通流能力达到100kA、10kA标称放电电流下残压≤40kV、机械抗弯负荷≥8kN;2、冰闪雨闪电压相比普通复合绝缘子提升15%以上;3、应用线路雷击跳闸率降低至0.2次/(100km.a)以下。...

光伏组件耐压测试时间要求

/61646UL1703漏电流测试zui大的额定系统电压耐压测试两倍于系统电压加上1000V直流电压潮湿绝缘电阻测试500V直流电压VDE0126工频耐压试验2000V+4倍的额定电压交流电压)湿漏电流试验等同现行的IEC61215/61646耐压试验说明:IEC61215、61646、61730均未给出耐压测试的合格/失败判断依据,我们可以引用UL1703“Dielectric Volatage-Withstand...

高压开关动特性测试仪操作说明

④触发方式:内触发:仪器内部直流电源进行分、合闸操作;外触发:仪器内部直流电源不工作,现场电源(交流直流均可)操作开关动作。仪器做合(分)闸时,仪器的“外触发”接线直接并接到合(分)闸线圈上,开关动作时,仪器从线圈上取电压信号作计时起点。⑤传感器:旋转直线传感器二个选项,根据所用的传感器进行相应设定即可。⑥速度测试:如现场不是行程试验,将此项关闭,可以缩短试验时间,减轻试验强度。...