GSO ISO 10313:2014
环境空气 通过化学反应发出的光的方法测定臭氧浓度的质量

Ambient air - Determination of the mass concentration of ozone -Chemiluminescence method


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO ISO 10313:2014 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO ISO 10313:2014
发布
2014年
发布单位
GSO
当前最新
GSO ISO 10313:2014
 
 
适用范围
1 .l General This International Standard specifies a chemiluminescence method for the determination of the mass concentration of ozone in ambient air. The method is applicable to the determination of the mass concentration of ozone between 2 pg/m3 [O,OOl ppm(V/V)] and 10 mg/m3 [5 ppm(V/V)] at the reference conditions of 25 “C and 101,3 kPa. Ultraviolet (UV) photometry is specified as the primary calibration method because of its proven accuracy and specificity to ozone. The use of transfer Standards is allowed if they have been previously calibrated against the primary calibration method. 1.2 Limitations The chemiluminescent reaction of ozone with ethylene is not subject to interference from any of the common air pollutants. However, particulate matter, if not removed, will accumulate in the sampling line and may Cause a measurable destruction of ozone. If particulate matter is allowed to enter the reaction chamber of the analyser, it will not only scatter the emitted light but will also accumulate on the Optical window, thereby causing further attenuation of the emitted light. Also, any nitrogen(ll) Oxide in the sampled air will to some extent react with the ambient ozone; therefore, the time during which the ambient air remains in the sampling line must be sufficiently short to keep this effect to a minimum. NOTE 1 It has been reported by some researchers that, at about 80 % relative humidity and 22 “C, the responses for some commercially available chemiluminescence analysers were about 10 % higher than that for dry air. However, comparisons of ambient ozone measurements using commercially available chemiluminescence and UV-photometric analysers showed no significant differentes. This suggests that, in practice, any errors associated with calibrations using dry air are compensated by other effects.

GSO ISO 10313:2014相似标准


推荐

臭氧测定--紫外光度法介绍

②粒子过滤器:当空气中颗粒物浓度超过100μg/m3时,在紫外臭氧分析仪气体入口前应安装粒子过滤器。③采样泵:采样泵安装在气路末端,抽吸空气流过臭氧分析仪。④臭氧发生器:在仪器量程范围内发生稳定浓度臭氧。3.试剂及管线①零空气:在测定I0时,向光度计提供空气要取自与产生臭氧所用气源一致。②采样管线:采用不与臭氧化学反应惰性材料,如玻璃、聚四氟乙烯等。...

臭氧分析仪 型号MHY-27553

空气样品通过吸收池时被光度检测器测定光强度为I0;含臭氧空气样品通过吸收池时,被光度检测器测定光强度为I。...

紫外光度法测定臭氧含量注意事项

①本方法不受常见气体干扰,但受极少数有机物干扰,如笨及苯胺等在254nm处吸收紫外,对臭氧测定产生正干扰。除此之外,当被测环境空气中颗粒物浓度超过100μg/m3时,也将影响臭氧测定。视环境空气中颗粒物浓度和聚四氟乙烯滤膜污染程度应定期更换粒子过滤器滤膜。②由于臭氧不稳定,易分解,要求与仪器连接采样管线应尽可能短。...

HPE-1900系列紫外臭氧分析仪背景及分析

测定大气中臭氧浓度,对于构建空气质量模型和空气质量指标有非常重要意义。空气臭氧浓度范围一般是0 - 500ppb,这对臭氧分析仪精度有很高要求。目前高精度臭氧分析仪,主要以进口品牌为主。 图4.大气中臭氧(图片来源于网络)3. 海尔欣HPE臭氧分析仪介绍紫外线吸收法是现在在国际上流行物理方法分析臭氧方法。...