GSO IEC 60865-1:2015
短路电流影响的计算 第1部分:定义和计算方法

Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 GSO IEC 60865-1:2015 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
GSO IEC 60865-1:2015
发布
2015年
发布单位
GSO
当前最新
GSO IEC 60865-1:2015
 
 
适用范围
This part of IEC 60865 is applicable to the mechanical and thermal effects of short-circuit currents. It contains procedures for the calculation of – the electromagnetic effect on rigid conductors and flexible conductors, – the thermal effect on bare conductors. For cables and insulated conductors, reference is made, for example, to IEC 60949 and IEC 60986. For the electromagnetic and thermal effects in d.c. auxiliary installations of power plants and substations reference is made to IEC 61660-2. Only a.c. systems are dealt with in this standard. The following points should, in particular, be noted: a) The calculation of short-circuit currents should be based on IEC 60909. For the determination of the greatest possible short-circuit current, additional information from other IEC standards may be referred to, e.g. details about the underlying circuitry of the calculation or details about current-limiting devices, if this leads to a reduction of the mechanical stress. b) Short-circuit duration used in this standard depends on the protection concept and should be considered in that sense. c) These standardized procedures are adjusted to practical requirements and contain simplifications which are conservative. Testing or more detailed methods of calculation or both may be used. d) In Clause 5 of this standard, for arrangements with rigid conductors, only the stresses caused by short-circuit currents are calculated. Furthermore, other stresses can exist, e.g. caused by dead-load, wind, ice, operating forces or earthquakes. The combination of these loads with the short-circuit loading should be part of an agreement and/or be given by standards, e.g. erection-codes. The tensile forces in arrangements with flexible conductors include the effects of deadload. With respect to the combination of other loads the considerations given above are valid. e) The calculated loads are design loads and should be used as exceptional loads without any additional partial safety factor according to installation codes of, for example, IEC 61936-1 [1]1.

GSO IEC 60865-1:2015相似标准


推荐

《电池检测应量“光“而行》

在地面上任何地方都不能排除大气 吸收对太阳辐射影响,因此引入大气质量(air mass,AM)概念。       可以看出,太阳当顶时海平面处为AM1 ;外层空间不通过大气情况为AM0 ;通常接近人类生活现实太阳高度角41.8°情况为AM1.5。太阳常数为AM0 条件下太阳辐射通量,AM0 光谱主要用于评估太空用光伏电池组件性能。...

带您深入浅出了解太阳电池光电性能指标参数

3.短路电流密度Jsc太阳电池单位面积输出短路电流,就是短路电流密度。 理论计算得出Jsc 与实测Jsc 可能存在差异,产生差异主要原因是实测时所用太阳光模拟器光谱辐射曲线与AM1.5G 标准太阳光谱辐射曲线存在差异。4.峰值功率 Pm太阳电池片在正常工作或测试条件下最大输出功率,就是峰值功率。峰值功率取决于太阳辐照度、太阳光谱分布电池片工作温度等条件。...

变压器短路阻抗作用计算方法

通常Uz以额定电压百分数表示,即uz=(Uz/U1n)*100%。  变压器短路阻抗在运行中作用:  当变压器满载运行时,短路阻抗高低对二次侧输出电压高低有一定影响短路阻抗小,电压降小,短路阻抗大,电压降大。  当变压器负载出现短路时,短路阻抗小,短路电流大,变压器承受电动力大。短路阻抗大,短路电流小,变压器承受电动力小。  ...

电路基础知识最全汇总(一)

5.电路断路与短路电路断路处:I=0,U≠0 电路短路处:U=0,I≠0 。基尔霍夫定律 :1.几个概念:支路:是电路一个分支。结点:三条(或三条以上)支路联接点称为结点。回路:由支路构成闭合路径称为回路。网孔:电路中无其他支路穿过回路称为网孔。2.基尔霍夫电流定律:(1定义:任一时刻,流入一个结点电流代数为零。或者说:流入电流等于流出电流。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号