IEC 61828:2001
超声 聚焦传感器 定义及传送场的测量方法

Ultrasonics - Focusing Transducers - Definitions and Measurement Methods for the Transmitted Fields (Edition 1.0)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC 61828:2001 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
IEC 61828:2001
发布
2001年
中文版
GB/T 20249-2006 (等同采用的中文版本)
发布单位
国际电工委员会
替代标准
IEC 61828:2006
当前最新
IEC 61828:2020
 
 
适用范围
This International Standard - provides definitions for the transmitted field characteristics of focusing transducers for applications in medical ultrasound; - relates these definitions to theoretical descriptions, design, and measurement of the transmitted fields of focusing transducers; - gives measurement methods for obtaining defined characteristics of focusing transducers; - specifies beam axis alignment methods appropriate for focusing transducers. This International Standard relates to focusing ultrasonic transducers operating in the frequency range appropriate to medical ultrasound (0,5 MHz to 40 MHz) for both therapeutic and diagnostic applications. It shows how the characteristics of the transmitted field of transducers may be described from the point of view of design, as well as measured by someone with no prior knowledge of the construction details of a particular device. The radiated ultrasound field for a specified excitation is measured by a hydrophone in either a standard test medium (for example, water) or in a given medium. The standard applies only to media where the field behaviour is essentially like that in a fluid (i.e. where the influence of shear waves and elastic anisotropy is small), including soft tissues and tissue-mimicking gels. Any aspects of the field that affect their theoretical description or are important in design are also included. These definitions would have use in scientific communications, system design and description of the performance and safety of systems using these devices. This standard incorporates definitions from other related standards where possible, and supplies new, more specific terminology, both for defining focusing characteristics and for providing a basis for measurement of these characteristics. note: 1 Specifically, IEC 61102 and IEC 61157 (see clause 2).

IEC 61828:2001相似标准


推荐

专利 | 应用于不均匀流热式多孔板气体流量计

本发明流量计经实验室标准流量计进行标定,获得速度传感器和温度传感器一次测量信号与气体流量之间换算关系式,在信号变送器中,一次信号进行计算处理与传送或直接显示。为了提高测量准确性,温度传感器和速度传感器安装在内套管内下端口;信号变送器设在外套管外。为了进一步提高测量准确性,速度传感器上游内套管长度与直径或当量直径比值大于10。内套管流通截面小于外套管流通截面的1/10。...

超声传感器远程液位测量方法基本原理详解

液体液位准确测量是实现生产过程检测和实时控制重要保障,也是实现安全生产重要环节。在我国很多地方都需要远程水位监控,如工厂蓄水池、农田灌溉用水库、供水水塔、河道水位等。做好这些领域远程监控水位很重要。下面工采网小编具体来给大家介绍一下基于超声传感器液位测量方法超声波液位传感器基本原理。...

技术进步推动智能传感器发展

传感器量程精度基础  物理特性对感知功能至关重要,这些科学法则决定了量程范围和精度。电感式接近传感器超声传感器是现有传感器中最常见类型。  感应接近式传感器,内部有线圈,可以产生一个射频,来检测目标对象存在。为了达到最佳精度和准确度,工程师们应该选择最小射频来检测目标对象。  这是因为重复性和滞后性。重复性是操作点在重复操作时准确度,通常为检测范围2%或更小。...

超声波换能器组成与类型

这有助于提高近表面分辨率,并且横梁设计也有助于创建焦点,使双元件换能器对腐蚀和点蚀引起不规则缺陷回波更加敏感。  浸入式换能器比接触式换能器具有多个优势。首先,它们均匀耦合减小了灵敏度变化。其次,浸入式传感器通过执行自动扫描能力提供了更高速度。第三,浸没式换能器聚焦提高了对小缺陷敏感性。  浸入式换能器有未聚焦,球形聚焦和圆柱形聚焦配置。未聚焦浸没式换能器通常用于厚材料测量中。...


IEC 61828:2001 中可能用到的仪器设备


谁引用了IEC 61828:2001 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved