ANSI/ASTM E1570-1995
计算机断层摄影(CT)检验惯例

Practice for Computed Tomographic (Ct) Examination


ANSI/ASTM E1570-1995 发布历史

Computed tomography (CT) may be used for new applications, or, in place of film radiography, provided that the capability to disclose physical features or indications that form the accept/reject criteria is fully documented and available for review. The CT systems addressed in this practice utilize a set of transmission measurements made along a set of paths projected through the test object from many different directions. Each of the transmission measurements within these views is digitized and stored in a computer, where they are subsequently conditioned (for example, normalized and corrected) and reconstructed by one of a variety of techniques. An in-depth treatment of CT principles is given in Guide E1441. Computed tomography (CT), as with conventional radiography and radioscopic examination, is broadly applicable to any material or test object through which a beam of penetrating radiation may be passed and detected, including metals, plastics, ceramics, metallic/nonmetallic composite material, and assemblies. The principal advantage of CT is that it provides densitometric (that is, radiological density and geometry) images of thin cross sections through an object. Because of the absence of structural superposition, images are much easier to interpret than conventional radiological images. The new user can quickly learn to read CT data because images correspond more closely to the way the human mind visualizes 3D structures than conventional projection radiology. Further, because CT images are digital, the images may be enhanced, analyzed, compressed, archived, input as data into performance calculations, compared with digital data from nondestructive evaluation (NDE) modalities, or transmitted to other locations for remote viewing, or a combination thereof. While many of the details are generic in nature, this practice implicitly assumes the use of penetrating radiation, specifically x ray and [gamma] ray. This practice provides procedural information for performing CT examinations. The techniques and the applications associated with CT examination are diverse. This practice is not intended to be limiting or restrictive, but rather to address the general use of CT technology and thereby facilitate its use. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety statements, see Section 8, NBS Handbook 114, and Federal Standards 21 CFR 1020.40 and 29 CFR 1910.96.

ANSI/ASTM E1570-1995由美国国家标准学会 US-ANSI 发布于 1995。

ANSI/ASTM E1570-1995 在中国标准分类中归属于: C43 医用射线设备,在国际标准分类中归属于: 35.240.80 信息技术在医药卫生技术中的应用。

ANSI/ASTM E1570-1995的历代版本如下:

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ANSI/ASTM E1570-1995 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ANSI/ASTM E1570-1995
发布日期
1995年
实施日期
废止日期
中国标准分类号
C43
国际标准分类号
35.240.80
发布单位
US-ANSI
适用范围
Computed tomography (CT) may be used for new applications, or, in place of film radiography, provided that the capability to disclose physical features or indications that form the accept/reject criteria is fully documented and available for review. The CT systems addressed in this practice utilize a set of transmission measurements made along a set of paths projected through the test object from many different directions. Each of the transmission measurements within these views is digitized and stored in a computer, where they are subsequently conditioned (for example, normalized and corrected) and reconstructed by one of a variety of techniques. An in-depth treatment of CT principles is given in Guide E1441. Computed tomography (CT), as with conventional radiography and radioscopic examination, is broadly applicable to any material or test object through which a beam of penetrating radiation may be passed and detected, including metals, plastics, ceramics, metallic/nonmetallic composite material, and assemblies. The principal advantage of CT is that it provides densitometric (that is, radiological density and geometry) images of thin cross sections through an object. Because of the absence of structural superposition, images are much easier to interpret than conventional radiological images. The new user can quickly learn to read CT data because images correspond more closely to the way the human mind visualizes 3D structures than conventional projection radiology. Further, because CT images are digital, the images may be enhanced, analyzed, compressed, archived, input as data into performance calculations, compared with digital data from nondestructive evaluation (NDE) modalities, or transmitted to other locations for remote viewing, or a combination thereof. While many of the details are generic in nature, this practice implicitly assumes the use of penetrating radiation, specifically x ray and [gamma] ray. This practice provides procedural information for performing CT examinations. The techniques and the applications associated with CT examination are diverse. This practice is not intended to be limiting or restrictive, but rather to address the general use of CT technology and thereby facilitate its use. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety statements, see Section 8, NBS Handbook 114, and Federal Standards 21 CFR 1020.40 and 29 CFR 1910.96.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号