BS ISO 8529-1-2001
基准中子辐射.特性和生产方法

Reference neutron radiations - Characteristics and methods of production


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS ISO 8529-1-2001 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
BS ISO 8529-1-2001
发布日期
2001年08月28日
实施日期
2001年08月28日
废止日期
中国标准分类号
A58
国际标准分类号
17.240
发布单位
GB-BSI
适用范围
This part of ISO 8529 specifies the reference neutron radiations, in the energy range from thermal up to 20 MeV, for calibrating neutron-measuring devices used for radiation protection purposes and for determining their response as a function of neutron energy. Reference radiations are given for neutron fluence rates of up to 1 × 10 m·-s, corresponding, at a neutron energy of 1 MeV, to dose-equivalent rates of up to 100 mSv·h. This part of ISO 8529 is concerned only with the methods of producing and characterizing the neutron reference radiations. The procedures for applying these radiations for calibrations are described in ISO 8529-2 and ISO 8529-3. The reference radiations specified are the following: — neutrons from radionuclide sources, including neutrons from sources in a moderator; — neutrons produced by nuclear reactions with charged particles from accelerators; — neutrons from reactors. In view of the methods of production and use of them, these reference radiations are divided, for the purposes of this part of ISO 8529, into the following two separate sections. — In clause 4, radionuclide neutron sources with wide spectra are specified for the calibration of neutron-measuring devices. These sources should be used by laboratories engaged in the routine calibration of neutron-measuring devices, the particular design of which has already been type tested. — In clause 5, accelerator-produced monoenergetic neutrons and reactor-produced neutrons with wide or quasi monoenergetic spectra are specified for determining the response of neutron-measuring devices as a function of neutron energy. Since these reference radiations are produced at specialized and well equipped laboratories, only the minimum of experimental detail is given. For the conversion of neutron fluence into the quantities recommended for radiation protection purposes, conversion coefficients have been calculated based on the spectra presented in normative annex A and using the fluence-to-dose-equivalent conversion coefficients as a function of neutron energy as given in ICRP Publication 74 and ICRU Report 57.

BS ISO 8529-1-2001系列标准





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号