IEC 61066:2006
个人和环境监测用热释光剂量测量系统

Thermoluminescence dosimetry systems for personal and environmental monitoring


标准号
IEC 61066:2006
发布
2006年
中文版
GB/T 10264-2014 (等同采用的中文版本)
发布单位
国际电工委员会
当前最新
IEC 61066:2006
 
 
适用范围
This International Standard applies to thermoluminescence dosimetry (TLD) systems that are used for measuring the personal dose equivalents Hp(10) or Hp(0,07) or the ambient dose equivalent H*(10) for external photon or beta radiation within the dose range from 0,01 mSv to 10 Sv. Different energy ranges are specified for different operational quantities and radiation types, as evident in the following Table. All the energy values given are mean energies with respect to the prevailing dose quantity. NOTE 1 In this standard, “dose” means personal or ambient dose equivalent, unless otherwise stated. NOTE 2 For Hp(10) and H*(10) no beta radiation is considered as no conversion coefficients are available, neither in ICRU 56, ICRU 57 nor in ISO 6980. This standard is intended to be applied to thermoluminescence dosimetry (TLD) systems that are capable of evaluating doses from readings in the required unit (Sv). The only correction that may be applied is the one resulting from natural background radiation using extra dosemeters. NOTE 3 The correction due to natural background may be made before or after the dose calculation. In this standard, requirements are stated, as a minimum, for fixed ranges of influence quantities, for example 80 keV to 1,25 MeV for photon energy (see Tables 3 to 5). A dosimetry system shall fulfil the requirements stated for these minimal ranges. However, the manufacturer may state larger ranges for the different influence quantities, for example 60 keV to 7 MeV. These larger ranges are called rated ranges. In such cases, the dosimetry systems must fulfil the requirements stated for these rated ranges. Thus, dosimetry systems can be classified by stating a set of ranges (for dose, energy, temperature, etc.) within which the requirements stated in this standard are met. For the dosimetry systems described above, this standard specifies general characteristics, general test procedures and performance requirements, radiation characteristics as well as environmental, electrical, mechanical, software and safety characteristics. The absolute calibration of the dosimetry system is not checked during a type test according to this standard as only system properties are of interest. The absolute calibration is checked during a routine test. This standard does not incorporate requirements for neutron dosemeters nor does it cover the handling of the resulting data.

IEC 61066:2006相似标准


推荐

市场监管总局:33项国家计量技术规范 涉酶联免疫分析仪

新公布的33项国家计量技术规范,包括个人和环境监测X、γ辐射剂量测量(装置)系统检定规程,气溶胶稀释器校准规范,X射线能谱仪校准规范,锥形量仪校准规范,静态热机械分析仪校准规范,塑料表观剪切黏度测定仪(毛细管流变仪)校准规范,实时频谱分析仪校准规范,全自动酶联免疫分析仪校准规范等。...

飞秒激光与固体靶相互作用产生的硬X射线能谱测量研究

美国率先用Li2B4O7和CaSo4熱剂量片和几种吸收滤片测量了0.5~3的硬X射线的能谱,但国内在强场物理研究中利用技术诊断硬X射线能谱的工作还没有开展,我们首先探索了灵敏度更高的LiF探测器诊断硬X射线能谱的方法,并在实验中获得了理想的结果。...

辐照食品鉴定及检测方法丨电子顺磁共振波谱仪&Lexsygsmart检测法

以G1 表示样品硅酸盐的一次发光曲线面积积分值;给予样品确定剂量的辐照后,再次测定样品的,并且G2 表示二次发光曲线的面积积分值,最终G1/G2 值判定样品是否经过辐照。 ...

物理学方法在古陶瓷考古中的应用(一)

将样品碎片夹碎,悬浮使之分离,将悬浮的颗粒沉积到圆盘上去测量;( 2 )利用夹杂物测定年代。一般利用陶器中的石英晶体;( 3 )前剂量法测定年代。根据灵敏度变化规律测出值。( 4 )还有其他方法,如相减技术、锆石或长石技术、薄片技术等 。2 、仪器专门的测定年代装置由加热系统测量和微计算机几部分组成。...


IEC 61066:2006 中可能用到的仪器设备


谁引用了IEC 61066:2006 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号