BS EN 14382:2005
气压调节站和装置用安全设备.进气口压力不超过100bar的气体安全截止装置

Safety devices for gas pressure regulating stations and installations - Gas safety shut-off devices for inlet pressures up to 100 bar

2006-02

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS EN 14382:2005 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “立即购买” 按钮开始采购(由第三方提供)。

 

标准号
BS EN 14382:2005
发布
2006年
发布单位
英国标准学会
替代标准
BS EN 14382:2005+A1:2009
当前最新
BS EN 14382:2019
 
 
适用范围
This document specifies constructional, functional, sizing, and testing requirements, also documentation and marking of gas safety shut-off devices used in the pressure regulating stations in accordance with EN 12186 or EN 12279: ? for inlet pressures up to 100 bar and nominal diameters up to DN 400; ? for an operating temperature range from –20 °C to +60 °C, which operate with fuel gases of the 1st and 2nd family in accordance with EN 437 in transmission and distribution networks and also in commercial and industrial installations. "Gas safety shut-off devices" will hereafter be called "SSDs" except in titles. The harmonized part of this document deals with standard safety shut-off devices used in pressure regulating stations complying with EN 12186 or EN 12279. For standard safety shut-off devices integral strength type when used in pressure regulating stations complying with EN 12186 or EN 12279, Annex ZA lists all applicable Essential Requirements except the external resistance to environmental conditions where corrosion occurs. This document considers the following classes of SSDs: temperature classes: ? class 1: operating temperature range from –10 °C to 60 °C; ? class 2: operating temperature range from –20 °C to 60 °C; functional classes: ? class A: SSDs that close when damage to the pressure sensing element occurs (applicable to overpressure SSDs only) or when external power fails; ? class B: SSDs that do not close when damage to the pressure sensing element occurs or are able to be opened automatically by the pressure control system (applicable to overpressure SSDs only). SSDs complying with the requirements of this document may be declared as “in conformity with EN 14382“ and bear the mark “EN 14382”. The material and functional requirements specified in this document may be applied to SSDs which use thermal energy or the effects of electrical energy to trip the operation of the closing member. For these SSDs the operational parameters are not specified in this document. This document does not apply to: ? SSDs upstream from/on/in domestic gas-consuming appliances which are installed downstream of domestic gas meters; ? SSDs in accordance with prEN xxxxxx (WI 00235003 under preparation by CEN/TC 235).

BS EN 14382:2005相似标准


推荐

合格实验室集中供气系统到底啥样?

所有减压阀需设有排气管路到气体存放区外。易燃气体、氧化气体排气管路不能并在一起。管道系统应设有调压装置,其组成包括各种阀门( 调节阀、截止阀、球阀等) ,实现气体开启、关闭、调节等作用。设单独阀门( 球阀或针阀) 控制工作台上气体出口。各种气体管道应有明显指示标志。安全减压阀标识需标明压力释放级别。使用氢气及可燃气体实验室应设置报警装置,放空管路上安装气体回火防止器。...

收藏:污水处理常用机械设备故障对照表

,如纤维等清除,使叶轮运转轻松泵内部件磨损更换泵送介质中含不允许空气或气体清除由于装置原因引起震动检查、重新调整、修复转向错误调线电机侧径向轴承损坏更换十二、鼓风常见故障及排除方法故障主要原因排除方法由压力计测量出或生产过程确定出低压力、真空、低容积流量反转调线空气或气体管道太小,弯头过多、产生过多损耗增加管道尺寸或安装具有较高压力机器进气口、排气口或管道系统局部阻塞清除进气口压力过低检查进气口是否具有障碍物或安装具有排气压力机器进气口温度过高进气口放在荫凉地方机器没有按约定速度运转检查电机转速...

干货来了!!!污水处理设备管理与维护手册大全!

,如纤维等清除,使叶轮运转轻松泵内部件磨损更换泵送介质中含不允许空气或气体清除由于装置原因引起震动检查、重新调整、修复转向错误调线电机侧径向轴承损坏更换十二、鼓风常见故障及排除方法故障主要原因排除方法由压力计测量出或生产过程确定出低压力、真空、低容积流量反转调线空气或气体管道太小,弯头过多、产生过多损耗增加管道尺寸或安装具有较高压力机器进气口、排气口或管道系统局部阻塞清除进气口压力过低检查进气口是否具有障碍物或安装具有排气压力机器进气口温度过高进气口放在荫凉地方机器没有按约定速度运转检查电机转速...

KNF隔膜泵安装要注意哪些问题

2、给隔膜泵供气:金属隔膜泵供气压力不得超过125PSI(8.6BAR),塑料泵供气压力不得超过100PSI(6.9BAR)。将泵进气口连接到有足够容量并且压力符合设计要求气源上。如果供气线路是硬管道,在泵管道之间连一短软管来减少扭曲。除了空气进气盖冒,空气进气管道、调压过滤器重量也必须通过某种方法支撑。如果不支撑管道也许会损坏泵。必须安装压力调节阀来确保供气压力超过规定范围。...