UL 1072-2006
中压电力电缆

UL Standard for Safety Medium-Voltage Power Cables Fourth Edition, Reprint with Revisions Through and Including September 19, 2007


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL 1072-2006 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
UL 1072-2006
发布日期
2006年06月30日
实施日期
废止日期
中国标准分类号
K13
国际标准分类号
29.060.20
发布单位
US-UL
被代替标准
UL 1072-2001
适用范围
1.1 These requirements cover the shielded and - medium-voltage power cables that are described in Tables 1.1 (single-conductor) and 1.2 (multiple-conductor). Multiple-conductor cables may include one or more individually jacketed non-conductive optical-fiber members. These electrical and hybrid electrical and optical-fiber cables are for use (optical and electrical functions associated in the case of a hybrid cable) in accordance with Article 328 and other applicable parts of the National Electrical Code (NEC), ANSI/NFPA 70. These cables have one or more stranded copper or aluminum conductors that are insulated with a solid, extruded dielectric. Cables that have a metal sheath or interlocked armor incorporate an effective grounding path. A grounding conductor is optional in other cables. Cables for direct burial are so marked and have an overall covering (see 1.4 for direct-burial cables that are not covered). Cables that are for use in cable trays generally are so marked (see 62.1 and 62.2). Cables that are sunlight-resistant generally are so marked (see 64.1 - 64.3). Cables that are marked "MV-90" or "MV-90 dry" have a maximum operating temperature of 90鳦 (194鳩). Cables that are marked "MV-105" have a maximum operating temperature of 105鳦 (221鳩) for use where design conditions require a maximum conductor temperature above 90鳦 (194鳩). Cables that are marked "dry" have insulation for use only in dry locations. All other cables have insulation that is for use in both wet and dry locations. Multiple-conductor cables that include one or more optical-fiber members are surface marked to so indicate. Cables that are marked "oil resistant II" are for exposure to mineral oil at temperatures not in excess of 75鳦 (167鳩). Cables that are marked "oil resistant I" are for exposure to mineral oil at temperatures not in excess of 60鳦 (140鳩). A multiple-conductor Type MV cable that has a smooth (other than lead) or corrugated metal sheath or that has interlocked metal armor may be marked for use also as Type MC cable. This standard does not include requirements for cables with concentric neutral conductors. However, it is possible to have a single-conductor cable with a concentric neutral conductor manufactured in accordance with the requirements of other standards, that meets the requirements for jacketed single-conductor shielded cable in this standard.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号