DIN EN 15218-2007
空间冷却用带蒸汽冷凝器和电驱动压缩机的空气调节装置和液态制冷包.术语、定义、试验条件、试验方法和要求

Air conditioners and liquid chilling packages with evaporatively cooled condenser and with electrically driven compressors for space cooling - Terms, definitions, test conditions, test methods and requirements; English version of DIN EN 15218:2007-01


DIN EN 15218-2007 发布历史

This standard specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank. This standard does not apply to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator. This standard does not apply to units equipped with a water tank or with a continuous water circuit supply that cannot operate without water feeding. This standard applies to factory-made units which can be ducted. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by (his standard. With regard to units consisting of several parts, this standard applies only to those designed and supplied as a complete package. Installations used for industrial processes cooling are not within the scope of this standard. NOTE All the symbols given in this text should be used regardless of language.

DIN EN 15218-2007由德国标准化学会 DE-DIN 发布于 2007-01。

DIN EN 15218-2007 在中国标准分类中归属于: J73 制冷设备,Q76 建筑暖通、空调器材设备,在国际标准分类中归属于: 27.200 制冷技术,91.140.30 通风和空调。

DIN EN 15218-2007的历代版本如下:

  • 2007年01月 DIN EN 15218-2007 空间冷却用带蒸汽冷凝器和电驱动压缩机的空气调节装置和液态制冷包.术语、定义、试验条件、试验方法和要求
  • 2013年10月 DIN EN 15218-2013 空间冷却用带蒸汽冷凝器和电驱动压缩机的空气调节装置和液态制冷包.术语、定义、试验条件、试验方法和要求.德文版本EN 15218-2013

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 DIN EN 15218-2007 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
DIN EN 15218-2007
发布日期
2007年01月
实施日期
废止日期
中国标准分类号
J73;Q76
国际标准分类号
27.200;91.140.30
发布单位
DE-DIN
代替标准
DIN EN 15218-2013
适用范围
This standard specifies the terms, definitions, test conditions, test methods and requirements for rating the performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This additional external water is fed by a specific water supply circuit or by a water tank. This standard does not apply to air-to-air and air-to-water air conditioners with a condenser cooled by air and by the evaporation of water condensed on their evaporator. This standard does not apply to units equipped with a water tank or with a continuous water circuit supply that cannot operate without water feeding. This standard applies to factory-made units which can be ducted. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by (his standard. With regard to units consisting of several parts, this standard applies only to those designed and supplied as a complete package. Installations used for industrial processes cooling are not within the scope of this standard. NOTE All the symbols given in this text should be used regardless of language.